00191494-01.pdf - 第28页
Error Messages Short Reference SIPLACE 80 S-15/F3/G 03/99 Issue Software Version SR.010.x x 26 268 Undefined reference point typ e CAUSE ● Axis board defective; lo cal machine data incorrect; error should not occur . REM…
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
25
261 Component too large for opt. multiple measurement
CAUSE
● The number of measurements determined by the vision system is greater than the maximum per-
mitted number.
REMEDY
● Check the package form data.
262 Undefined axis command
CAUSE
● Axis board defective; local machine data incorrect; error should not occur.
REMEDY
● Fit new axis board.
263 Undefined positioning type
CAUSE
● Axis board defective; local machine data incorrect; error should not occur.
REMEDY
● Fit new axis board.
264 Limit switch actuated
CAUSE
● Limit switch defective; axis miscounting and moving up against limit switch.
REMEDY
● Clean scale; call Siemens Service.
265 Position outside travel range
CAUSE
● Error in the local machine data.
REMEDY
● Check positions.
266 Position contains an invalid character
CAUSE
● Axis board defective; local machine data incorrect; error should not occur.
REMEDY
● Fit new axis board.
267 Position contains an invalid prefix character
CAUSE
● Axis board defective; local machine data incorrect; error should not occur.
REMEDY
● Fit new axis board.
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
26
268 Undefined reference point type
CAUSE
● Axis board defective; local machine data incorrect; error should not occur.
REMEDY
● Fit new axis board.
269 Acceleration/deceleration too great
CAUSE
● Axis board defective; local machine data incorrect; error should not occur.
REMEDY
● Fit new axis board.
270 PCB interrupted due to EMERGENCY STOP
CAUSE
● The guard was opened or the EMERGENCY STOP button pressed while placement was in pro-
gress.
REMEDY
● Before opening the guard press the STOP switch and wait until the machine stops.
271 Check sum error of coplanarity
CAUSE
● Error in the command to the coplanarity.
REMEDY
● Repeat measurement; check supply voltage; jumper check.
272 Vision system not providing measure result
CAUSE
● No component at the nozzle; component outside tolerance; not enough image information to pro-
vide measurement result.
REMEDY
● Optimize pick-up; check charge (component) .
275 VS: Unknown request
CAUSE
● Incorrect ICOS software version.
REMEDY
● Check eproms and replace if necessary.
276 VS: Data not correct during request
CAUSE
● Incorrect camera number in IDEAL.MA; obsolete ICOS software version.
REMEDY
● Correct the machine data (IDEAL.MA); check eproms and replace if necessary.
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
27
277 VS: Check sum error during data transmission
CAUSE
● Communications error
REMEDY
● If the error reoccurs with further attempts, first reset MVS, then station computer.
278 VS: Reference No. unknown, model not found
CAUSE
● The station refers to a package form or fiducial description which is not loaded in MVS/M10000.
REMEDY
● Load fiducials/package form description from vision system; check camera codes (IDEAL.MA/
REAL.MA).
279 VS: Incorrect parameters during request
CAUSE
● Incorrect camera number in IDEAL.MA; obsolete ICOS software version; FOV (field of view) data
in REAL.MA have too great a value.
REMEDY
● Correct the machine data (IDEAL.MA and REAL.MA); check eproms and replace if necessary.
280 VS: Not enough memory for a window definition
CAUSE
● Memory problems in the ICOS.
REMEDY
● Reset ICOS.
281 VS: Not enough memory for a definition
CAUSE
● ICOS cannot accept any further model descriptions.
REMEDY
● Reset ICOS and reload.
282 VS: Not enough memory for image
CAUSE
● Memory location problems in the ICOS.
REMEDY
● Reset ICOS.
283 Incorrect Eprom version in MVS
CAUSE
● The EPROM version in the MVS cannot be used with the station computer software. (Version dis-
played in the vision menu).
REMEDY
● Replace the EPROM in the MVS.