Error Messages Short Reference SIPLACE 80 S-15/F3/G 03/99 Issue Software Version SR.010.x x 26 268 Undefined reference point typ e CAUSE ● Axis board defective; lo cal machine data incorrect; error should not occur . REM…

100%1 / 124
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
25
261 Component too large for opt. multiple measurement
CAUSE
The number of measurements determined by the vision system is greater than the maximum per-
mitted number.
REMEDY
Check the package form data.
262 Undefined axis command
CAUSE
Axis board defective; local machine data incorrect; error should not occur.
REMEDY
Fit new axis board.
263 Undefined positioning type
CAUSE
Axis board defective; local machine data incorrect; error should not occur.
REMEDY
Fit new axis board.
264 Limit switch actuated
CAUSE
Limit switch defective; axis miscounting and moving up against limit switch.
REMEDY
Clean scale; call Siemens Service.
265 Position outside travel range
CAUSE
Error in the local machine data.
REMEDY
Check positions.
266 Position contains an invalid character
CAUSE
Axis board defective; local machine data incorrect; error should not occur.
REMEDY
Fit new axis board.
267 Position contains an invalid prefix character
CAUSE
Axis board defective; local machine data incorrect; error should not occur.
REMEDY
Fit new axis board.
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
26
268 Undefined reference point type
CAUSE
Axis board defective; local machine data incorrect; error should not occur.
REMEDY
Fit new axis board.
269 Acceleration/deceleration too great
CAUSE
Axis board defective; local machine data incorrect; error should not occur.
REMEDY
Fit new axis board.
270 PCB interrupted due to EMERGENCY STOP
CAUSE
The guard was opened or the EMERGENCY STOP button pressed while placement was in pro-
gress.
REMEDY
Before opening the guard press the STOP switch and wait until the machine stops.
271 Check sum error of coplanarity
CAUSE
Error in the command to the coplanarity.
REMEDY
Repeat measurement; check supply voltage; jumper check.
272 Vision system not providing measure result
CAUSE
No component at the nozzle; component outside tolerance; not enough image information to pro-
vide measurement result.
REMEDY
Optimize pick-up; check charge (component) .
275 VS: Unknown request
CAUSE
Incorrect ICOS software version.
REMEDY
Check eproms and replace if necessary.
276 VS: Data not correct during request
CAUSE
Incorrect camera number in IDEAL.MA; obsolete ICOS software version.
REMEDY
Correct the machine data (IDEAL.MA); check eproms and replace if necessary.
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
27
277 VS: Check sum error during data transmission
CAUSE
Communications error
REMEDY
If the error reoccurs with further attempts, first reset MVS, then station computer.
278 VS: Reference No. unknown, model not found
CAUSE
The station refers to a package form or fiducial description which is not loaded in MVS/M10000.
REMEDY
Load fiducials/package form description from vision system; check camera codes (IDEAL.MA/
REAL.MA).
279 VS: Incorrect parameters during request
CAUSE
Incorrect camera number in IDEAL.MA; obsolete ICOS software version; FOV (field of view) data
in REAL.MA have too great a value.
REMEDY
Correct the machine data (IDEAL.MA and REAL.MA); check eproms and replace if necessary.
280 VS: Not enough memory for a window definition
CAUSE
Memory problems in the ICOS.
REMEDY
Reset ICOS.
281 VS: Not enough memory for a definition
CAUSE
ICOS cannot accept any further model descriptions.
REMEDY
Reset ICOS and reload.
282 VS: Not enough memory for image
CAUSE
Memory location problems in the ICOS.
REMEDY
Reset ICOS.
283 Incorrect Eprom version in MVS
CAUSE
The EPROM version in the MVS cannot be used with the station computer software. (Version dis-
played in the vision menu).
REMEDY
Replace the EPROM in the MVS.