Short Reference SIPLACE 80 S-15/F3/G Error Messages 03/99 Issue Software Version SR.010.x x 13 143 Desired Z-axis position exceeded during nozzle SP pick-up CAUSE ● The position of the x and y a xes in the machine data i…

100%1 / 124
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
12
137 Not enough garages in changer magazine for nozzle return. SP
CAUSE
Nozzles should be returned
With optical garage check: all garages were checked with the board camera and are occupied.
Without optical garage check: there are not enough empty garages available for the nozzles to be
returned.
REMEDY
Takes place automatically: all nozzles which could not be returned are rejected.
138 Insuff. number of nozzles in changer magazine SP to pick up
CAUSE
Nozzles are to be picked up
With optical garage check: All garages have been checked with the board camera and are empty
Without optical garage check: One or more garages of the required nozzle type is empty.
REMEDY
The corresponding magazines must be set full via the menu.
139 No cluster available for nozzle pick-up SP
CAUSE
No cluster has been specified as specified selection.
REMEDY
Specifiy placement program in the line computer.
140 Nozzle-changer SP head cannot be unlocked
CAUSE
Key plate for locking the nozzle-changer magazine cannot be unlocked.
The plate is jamming mechanically, due to components etc.
Incorrect compressed air setting for the actuating cylinder; lacking air pressure;
the cylinder or valve is defective.
REMEDY
Correction of the above causes
141 Nozzle-changer SP head cannot be locked
CAUSE
Key plate for locking the nozzle-changer magazine cannot be unlocked.
The plate is jamming mechanically, due to components etc.
Incorrect compressed air setting for the actuating cylinder; lacking air pressure;
the cylinder or valve is defective.
REMEDY
Correction of the above causes
142 Communication with vision system during nozzle check faulty
CAUSE
Communication with the vision system is faulty.
REMEDY
Switch the system on and off (reset); notify Siemens Service Department.
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
13
143 Desired Z-axis position exceeded during nozzle SP pick-up
CAUSE
The position of the x and y axes in the machine data is not correct;
the desired position of the Z-axis is not correct; there is no nozzle in the garage.
REMEDY
Correction of the above causes
144 Desired Z-axis position not reached during nozzle SP pick-up
CAUSE
The position of the x and y axes in the machine data is not correct (sleeve is not positioned over
the garage);
desired position of the Z-axis is not correct; there is already a nozzle at the sleeve.
REMEDY
Correction of the above causes
145 Desired Z-axis position exceeded during nozzle SP return
CAUSE
The position of the x and y axes in the machine data is not correct;
desired position of the Z-axis is not correct; there is no nozzle at the sleeve.
REMEDY
Correction of the above causes
146 Desired Z-axis position not reached during nozzle SP return
CAUSE
The position of the x and y axes in the machine data is not correct (sleeve is not positioned over
the garage);
desired position of the Z-axis is not correct; there is already a nozzle in the garage.
REMEDY
Correction of the above cause
147 Desired Z-axis position exceeded during nozzle SP rejection
CAUSE
The position of the x and y axes in the machine data is not correct ;
desired position of the Z-axis is not correct; there is no nozzle at the sleeve.
REMEDY
Correction of the above causes
148 Desired Z-axis position not reached during nozzle SP rejection
CAUSE
The position of the x and y axes in the machine data is not correct (sleeve not above garage);
desired position of the Z-axis is not correct; there is already a nozzle in the garage.
REMEDY
Correction of the above causes
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
14
149 Nozzle SP change not completed
CAUSE
This error message is issued when after an automatic change the actual state of the nozzle confi-
guration does not yet correspond with the desired state.
REMEDY
In the menu "Display errors" list the error and case by case:
set the magazine(s) full;
set up nozzle-changer;
select the menu "Pick up all nozzles";
NOTE
While this is running when there is a fault the magazine and garage numbers will be displayed in the
"General errors" menu.
The following will apply: Info1 = Magazine number
Info2 = Garage number
150 Nozzle SP pick-up not completed
CAUSE
During automatic change or when the "Pick up all nozzles" menu was called it was not possible to
pick up all nozzles because:
there are too few nozzles in the corresponding magazine;.
the magazine is empty or was not installed.
REMEDY
In the menu "Display error" list the error and case by case:
set the magazine(s) full;
set up nozzle-changer;
select the menu "Pick up all nozzles";
NOTE
While this is running when there is a fault the magazine and garage numbers will be displayed in the
"General errors" menu.
The following will apply: Info1 = Magazine number
Info2 = Garage number