00191494-01.pdf - 第15页
Short Reference SIPLACE 80 S-15/F3/G Error Messages 03/99 Issue Software Version SR.010.x x 13 143 Desired Z-axis position exceeded during nozzle SP pick-up CAUSE ● The position of the x and y a xes in the machine data i…
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
12
137 Not enough garages in changer magazine for nozzle return. SP
CAUSE
● Nozzles should be returned ⇒
With optical garage check: all garages were checked with the board camera and are occupied.
Without optical garage check: there are not enough empty garages available for the nozzles to be
returned.
REMEDY
● Takes place automatically: all nozzles which could not be returned are rejected.
138 Insuff. number of nozzles in changer magazine SP to pick up
CAUSE
● Nozzles are to be picked up ⇒
With optical garage check: All garages have been checked with the board camera and are empty
Without optical garage check: One or more garages of the required nozzle type is empty.
REMEDY
● The corresponding magazines must be set full via the menu.
139 No cluster available for nozzle pick-up SP
CAUSE
● No cluster has been specified as specified selection.
REMEDY
● Specifiy placement program in the line computer.
140 Nozzle-changer SP head cannot be unlocked
CAUSE
● Key plate for locking the nozzle-changer magazine cannot be unlocked.
The plate is jamming mechanically, due to components etc.
Incorrect compressed air setting for the actuating cylinder; lacking air pressure;
the cylinder or valve is defective.
REMEDY
● Correction of the above causes
141 Nozzle-changer SP head cannot be locked
CAUSE
● Key plate for locking the nozzle-changer magazine cannot be unlocked.
The plate is jamming mechanically, due to components etc.
Incorrect compressed air setting for the actuating cylinder; lacking air pressure;
the cylinder or valve is defective.
REMEDY
● Correction of the above causes
142 Communication with vision system during nozzle check faulty
CAUSE
● Communication with the vision system is faulty.
REMEDY
● Switch the system on and off (reset); notify Siemens Service Department.
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
13
143 Desired Z-axis position exceeded during nozzle SP pick-up
CAUSE
● The position of the x and y axes in the machine data is not correct;
the desired position of the Z-axis is not correct; there is no nozzle in the garage.
REMEDY
● Correction of the above causes
144 Desired Z-axis position not reached during nozzle SP pick-up
CAUSE
● The position of the x and y axes in the machine data is not correct (sleeve is not positioned over
the garage);
desired position of the Z-axis is not correct; there is already a nozzle at the sleeve.
REMEDY
● Correction of the above causes
145 Desired Z-axis position exceeded during nozzle SP return
CAUSE
● The position of the x and y axes in the machine data is not correct;
desired position of the Z-axis is not correct; there is no nozzle at the sleeve.
REMEDY
● Correction of the above causes
146 Desired Z-axis position not reached during nozzle SP return
CAUSE
● The position of the x and y axes in the machine data is not correct (sleeve is not positioned over
the garage);
desired position of the Z-axis is not correct; there is already a nozzle in the garage.
REMEDY
● Correction of the above cause
147 Desired Z-axis position exceeded during nozzle SP rejection
CAUSE
● The position of the x and y axes in the machine data is not correct ;
desired position of the Z-axis is not correct; there is no nozzle at the sleeve.
REMEDY
● Correction of the above causes
148 Desired Z-axis position not reached during nozzle SP rejection
CAUSE
● The position of the x and y axes in the machine data is not correct (sleeve not above garage);
desired position of the Z-axis is not correct; there is already a nozzle in the garage.
REMEDY
● Correction of the above causes

Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
14
149 Nozzle SP change not completed
CAUSE
● This error message is issued when after an automatic change the actual state of the nozzle confi-
guration does not yet correspond with the desired state.
REMEDY
● In the menu "Display errors" list the error and case by case:
set the magazine(s) full;
set up nozzle-changer;
select the menu "Pick up all nozzles";
NOTE
While this is running when there is a fault the magazine and garage numbers will be displayed in the
"General errors" menu.
The following will apply: Info1 = Magazine number
Info2 = Garage number
150 Nozzle SP pick-up not completed
CAUSE
● During automatic change or when the "Pick up all nozzles" menu was called it was not possible to
pick up all nozzles because:
there are too few nozzles in the corresponding magazine;.
the magazine is empty or was not installed.
REMEDY
● In the menu "Display error" list the error and case by case:
set the magazine(s) full;
set up nozzle-changer;
select the menu "Pick up all nozzles";
NOTE
While this is running when there is a fault the magazine and garage numbers will be displayed in the
"General errors" menu.
The following will apply: Info1 = Magazine number
Info2 = Garage number