Short Reference SIPLACE 80 S-15/F3/G Error Messages 03/99 Issue Software Version SR.010.x x 9 79 Arm for turning station 1 has not sw ivelled out CAUSE ● Feed motor defective; proximit y switch defective. REMEDY ● Replac…
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
8
63 X-axis disabled
CAUSE
● X-axis switched off at the axis controller switch.
REMEDY
● X-axis should be switched on at the axis controller switch.
64 Y-axis disabled
CAUSE
● Y-axis switched off at the axis controller switch.
REMEDY
● Y-axis should be switched on at the axis controller switch.
65 D1-axis disabled
CAUSE
● DP1-axis switched off at the axis controller switch.
REMEDY
● DP1-axis should be switched on at the axis controller switch.
66 D2-axis disabled
CAUSE
● DP2-axis switched off at the axis controller switch.
REMEDY
● DP2-axis should be switched on at the axis controller switch.
67 Star axis disabled
CAUSE
● Star axis switched off at the axis controller switch.
REMEDY
● Star axis should be switched on at the axis controller switch.
68 Z-axis disabled
CAUSE
● Z-axis switched off at the axis controller switch.
REMEDY
● Z-axis should be switched on at the axis controller switch.
75 Programmed position of Z-axis outside travel range
CAUSE
● Machine data in the line computer erroneous; height reference run is not carried out on the PCB
conveyor.
REMEDY
● Check the machine data in the line computer.
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
9
79 Arm for turning station 1 has not swivelled out
CAUSE
● Feed motor defective; proximity switch defective.
REMEDY
● Replace feed motor; carry out axis calibration; fit new proximity switch.
80 Arm for turning station 2 has not swivelled out
CAUSE
● Feed motor defective; proximity switch defective.
REMEDY
● Replace feed motor; carry out axis calibration; fit new proximity switch.
94 DETERMINANT not correct during position recognition
CAUSE
● The two fiducials of a circuit image are on one position; the three fiducials of a circuit image are in
a line.
REMEDY
● Correct placement program in the line computer.
95 Fiducial missing in position recognition
CAUSE
● Fiducial quality of a fiducial not adequate; PCB transport adjusted imprecisely; camera illumina-
tion defective; search field too small.
REMEDY
● Clean fiducial; reteach fiducial (increase size of search field); check conveyor width; check stop-
per setting.
96 CORR_MOVE not correct during position recognition
CAUSE
● The two fiducials of a circuit image are on one position.
REMEDY
● Correct placement program in the line computer.
101 Track empty, no component during pick-up
CAUSE
● On a single track at least three pick-up errors occurred immediately after one another; no compo-
nent in the pick-up position; set up for incorrect component (e.g. cubic instead of non-cubic).
feeder jamming; cover foil parted.
REMEDY
● Refill components and reset track; check set-up.
get feeder working properly again.
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
10
102 Quality too low during optical centering
CAUSE
● Parameters for optical centering erroneous.
REMEDY
● Check the package form in the components manipulator.
103 Spacing of a pin group out of tolerance
CAUSE
● Bent terminal pin; pitch error limit defined too small.
REMEDY
● Check components; increase pitch error limit in the package form editor.
104 Component angle outside of tolerance
CAUSE
● Angular positioning deviation of the component on the nozzle too great; angular positioning tole-
rance defined too small.
REMEDY
● Improve pick-up; increase angular positioning tolerance.
121 Peak offset: no result
CAUSE
● Component terminal pin bent.
REMEDY
● Check quality of the components.
122 Coplanarity module cannot be initialized
CAUSE
● Coplanarity module not plugged in; configuration jumper incorrectly set
REMEDY
● Plug in module; correct jumper.
123 Coplan.: Data value outside of range
CAUSE
● Error in cluster or set-up: PF file faulty
REMEDY
● Check data for coplanarity in cluster and set-up; check PF data.
124 Vacuum reduction at placem. stat. too slow
CAUSE
● During placement of a component the vacuum does not reduce fast enough;
forced air not present; forced air defective.
REMEDY
● Check forced air; check forced air valve.