00191494-01.pdf - 第12页
Error Messages Short Reference SIPLACE 80 S-15/F3/G 03/99 Issue Software Version SR.010.x x 10 102 Quality too low during optical centering CAUSE ● Parameters for optical c entering erroneous. REMEDY ● Check the package …
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
9
79 Arm for turning station 1 has not swivelled out
CAUSE
● Feed motor defective; proximity switch defective.
REMEDY
● Replace feed motor; carry out axis calibration; fit new proximity switch.
80 Arm for turning station 2 has not swivelled out
CAUSE
● Feed motor defective; proximity switch defective.
REMEDY
● Replace feed motor; carry out axis calibration; fit new proximity switch.
94 DETERMINANT not correct during position recognition
CAUSE
● The two fiducials of a circuit image are on one position; the three fiducials of a circuit image are in
a line.
REMEDY
● Correct placement program in the line computer.
95 Fiducial missing in position recognition
CAUSE
● Fiducial quality of a fiducial not adequate; PCB transport adjusted imprecisely; camera illumina-
tion defective; search field too small.
REMEDY
● Clean fiducial; reteach fiducial (increase size of search field); check conveyor width; check stop-
per setting.
96 CORR_MOVE not correct during position recognition
CAUSE
● The two fiducials of a circuit image are on one position.
REMEDY
● Correct placement program in the line computer.
101 Track empty, no component during pick-up
CAUSE
● On a single track at least three pick-up errors occurred immediately after one another; no compo-
nent in the pick-up position; set up for incorrect component (e.g. cubic instead of non-cubic).
feeder jamming; cover foil parted.
REMEDY
● Refill components and reset track; check set-up.
get feeder working properly again.
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
10
102 Quality too low during optical centering
CAUSE
● Parameters for optical centering erroneous.
REMEDY
● Check the package form in the components manipulator.
103 Spacing of a pin group out of tolerance
CAUSE
● Bent terminal pin; pitch error limit defined too small.
REMEDY
● Check components; increase pitch error limit in the package form editor.
104 Component angle outside of tolerance
CAUSE
● Angular positioning deviation of the component on the nozzle too great; angular positioning tole-
rance defined too small.
REMEDY
● Improve pick-up; increase angular positioning tolerance.
121 Peak offset: no result
CAUSE
● Component terminal pin bent.
REMEDY
● Check quality of the components.
122 Coplanarity module cannot be initialized
CAUSE
● Coplanarity module not plugged in; configuration jumper incorrectly set
REMEDY
● Plug in module; correct jumper.
123 Coplan.: Data value outside of range
CAUSE
● Error in cluster or set-up: PF file faulty
REMEDY
● Check data for coplanarity in cluster and set-up; check PF data.
124 Vacuum reduction at placem. stat. too slow
CAUSE
● During placement of a component the vacuum does not reduce fast enough;
forced air not present; forced air defective.
REMEDY
● Check forced air; check forced air valve.
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
11
125 Coplanarity: clamping of Z-axis does not work
CAUSE
● Clamping reacts too slow; clamping is defective.
REMEDY
● Operate clamping repeatedly; check clamping.
126 Unknown telegram to table
CAUSE
● Obsolete
TISCH.HEX
file.
REMEDY
● Update
TISCH.HEX
file.
129 Communication table-feeder interrupted
CAUSE
● Since the last booting, the connection with the conveyor has been interrupted; the conveyor is not
plugged in; cable is defective.
REMEDY
● Plug in the conveyor; check the cable.
130 Communication table-feeder disturbed
CAUSE
● Communication between table and conveyor is interrupted from time to time; the cable is defec-
tive; the conveyor has been unplugged.
REMEDY
● Plug in the conveyor; check the cable and plug.
132 Foil torn
CAUSE
● The cover foil is torn; the foil removal force has been set incorrectly; the conveyor is defective.
REMEDY
● Repair the foil; adjust removal springs; replace the conveyor.
133 Foil not removed
CAUSE
● The cover foil is not being stripped off; the foil removal force has been set incorrectly; the con-
veyor is defective.
REMEDY
● Pull off the foil by hand; set removal spring
134 Transport in feeder disturbed
CAUSE
● Tape backing up; the conveyor is defective
REMEDY
● Remove tape back-up; replace the conveyor