00191494-01.pdf - 第61页

Short Reference SIPLACE 80 S-15/F3/G Error Messages 03/99 Issue Software Version SR.010.x x 59 539 WPC: Fault in lifting axis (servo or a xis card) CAUSE ● Axis board of the lifting axis d efective; Servo of the lifting …

100%1 / 124
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
58
527 Feeder rail of bulk case feeder not installed
CAUSE
The feeder rail is not installed on the bulk case feeder
REMEDY
Install feeder rail on bulk case feeder
533 WPC: Data loss in component table (defective battery)
CAUSE
Backup battery flat or defective; Controller A18 defective.
REMEDY
Replace battery; fit new A18 and inform Siemens Service.
534 WPC: Fault in feed axis (servo or axis card).
CAUSE
Axis board of the feed axis defective; servo of the feed axis defective.
REMEDY
Fit new axis board or servo board and inform Siemens Service.
535 WPC: Feed axis at limit switch
CAUSE
Feed axis at the limit switch; limit switch defective.
REMEDY
Push feed axis away from limit switch; fit new limit switch.
536 WPC: Axis error of feed axis
CAUSE
Undefined reference point or type of positioning; undefined axis command; position outside the
travel range.
REMEDY
Reboot; inform Siemens Service.
537 WPC: Feed axis servo released.
CAUSE
Servo disabled at the axis board.
REMEDY
Switch servo back on at the axis board.
538 WPC: Error in jaw position
CAUSE
At the zero point position the reference Bero of the feed axis is not actuated; incorrect zero point
correction; Bero defective.
REMEDY
Correct zero point correction; replace Bero.
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
59
539 WPC: Fault in lifting axis (servo or axis card)
CAUSE
Axis board of the lifting axis defective; Servo of the lifting axis defective.
REMEDY
Fit new axis board or servo board and inform Siemens Service.
540 WPC: Lifting axis at limit switch
CAUSE
Lifting axis at the limit switch; limit switch defective.
REMEDY
Release the brake of the lifting axis and push lifting axis away from limit switch; fit new limit
switch.
541 WPC: Axis error of lifting axis
CAUSE
Undefined reference point or type of positioning; undefined axis command; position outside the
travel range.
REMEDY
Reboot; inform Siemens Service.
542 WPC: Lifting axis servo released
CAUSE
Servo disabled at the axis board.
REMEDY
Switch servo back on at the axis board.
543 WPC: Control switched off.
CAUSE
Control of the component carriage failed; plugged connection faulty.
REMEDY
Check plugged connection and inform Siemens Service.
544 WPC: Protection at component table open.
CAUSE
Guard at the component carriage opened; protective switch or cable connection defective.
REMEDY
Close guard; fit new protective switch and check cable connection.
545 WPC: Error while transporting tray
CAUSE
When a tray is being supplied the "Tray ready" Bero is covered; the "Tray ready" Bero is defec-
tive; when a tray is being returned the "Tray in magazine" Bero is covered; the "Tray in magazine"
Bero is defective.
REMEDY
Check the "Tray ready" Bero and "Tray in magazine" Bero.
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
60
546 WPC: Error in saved set-up.
CAUSE
At pick-up of the component division number not in the set-up; checksum of the set-up erroneous.
REMEDY
Reboot and inform Siemens Service.
547 WPC: One tray of saved set-up missing
CAUSE
No tray present when changing levels; the "Tray in magazine" Bero is defective.
REMEDY
Fit new "Tray in magazine" Bero.
548 WPC: When returning tray, level occupied
CAUSE
Tray placed in travel range of the feed axis (when feed axis moved out);
the "Tray in magazine" Bero is defective.
REMEDY
Remove tray; fit new "Tray in magazine" Bero.
549 WPC: Tray has been taken out.
CAUSE
Ready tray was removed; the "Tray ready" Bero is defective.
REMEDY
Re-insert tray; fit new "Tray ready" Bero.
550 WPC: Take-over position already occupied
CAUSE
A tray already occupied the take-over position; the "Tray ready" Bero is defective.
REMEDY
Remove tray; fit new "Tray ready" Bero.
551 WPC: Tray in incorrect position or protection not closed properly.
CAUSE
Guard not correctly closed; tray positioned incorrectly; the "Lock against rotation " Bero is defec-
tive.
REMEDY
Close guard correctly; insert tray correctly; fit new "Lock against rotation" Bero.
552 WPC: Feed axis has touched protection.
CAUSE
The "Lock against rotation" Bero is defective; guard was opened during change procedure; tray
inserted incorrectly and driven against the guard.
REMEDY
Close guard; fit new "Lock against rotation" Bero; insert tray correctly.