Short Reference SIPLACE 80 S-15/F3/G Error Messages 03/99 Issue Software Version SR.010.x x 67 708 CRDL 2 configured without mechanic al centering CAUSE ● Despite the CRDL tester, the mechanical centering station has not…
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
66
702 BO: Mouse code not implemented (mouse code)
CAUSE
● BO has received an unknown message.
REMEDY
● Write down error message giving the complete error message and stating under what conditions
the error occurred. With the machine at standstill, reset the machine.
703 BO: CODE received unknown (code/state)
CAUSE
● BO has received unknown or unexpected message.
REMEDY
● Write down error message giving the complete error message and stating under what conditions
the error occurred. With the machine at standstill, reset the machine.
704 Text table could not be initialized at first attempt
CAUSE
● There is an error in the text table (text too long, for example)
REMEDY
● It is not necessary to stop operation. Please notify Siemens Service.
705 BO: Unknown element type in dialogue field (typ)
CAUSE
● Error in the data of the BO
REMEDY
● Write down error message giving the complete error message and stating under what conditions
the error occurred. With the machine at standstill, reset the machine.
706 BO: ID type unknown in menu (menuid_typ)
CAUSE
● Error in the data of the BO
REMEDY
● Write down error message giving the complete error message and stating under what conditions
the error occurred. With the machine at standstill, reset the machine.
707 CRDL 1 configured without mechanical centering
CAUSE
● Despite the CRDL tester, the mechanical centering station has not been configured (tester wit-
hout mechanical centering station is not possible)
REMEDY
● Correct the configuration in the line computer for this station.
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
67
708 CRDL 2 configured without mechanical centering
CAUSE
● Despite the CRDL tester, the mechanical centering station has not been configured (tester wit-
hout mechanical centering station is not possible)
REMEDY
● Correct the configuration in the line computer for this station.
709 BO: Event flag ID unknown (flag id)
CAUSE
● System error during system call SVC-Look for event flag group of the keyboard task
REMEDY
● When the machine is at a standstill, reset the machine.
710 BO: Error in RIO. HSFS_XREAD (sts)
CAUSE
● System error during keyboard input.
REMEDY
● When the machine is at a standstill, reset the machine.
711 BO: 1st state byte HSFS_XREAD (status[0])
CAUSE
● System error during keyboard input.
REMEDY
● When the machine is at a standstill, reset the machine.
712 BO: Error in RIO POLL_XBUF (sts)
CAUSE
● System error during keyboard input.
REMEDY
● When the machine is at a standstill, reset the machine.
713 BO: 1st status byte POLL_XBUF (status[0])
CAUSE
● System error during keyboard input.
REMEDY
● When the machine is at a standstill, reset the machine.
714 NF: no memory available
CAUSE
● System error
REMEDY
● Reboot
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
68
715 BO: Error in pause (sts)
CAUSE
● System error during system call PAUSE.
REMEDY
● When the machine is at a standstill, reset the machine.
716 BO Barcode terminator not found
CAUSE
● The terminator is missing after the barcode header, barcode at the barcode pen not recognized.
REMEDY
● Reread the barcode. If this does not work, check the barcode header and terminator.
717 BO: 1st character of barcode terminator not found
CAUSE
● The terminator is missing after the barcode header, barcode at the barcode pen not recognized.
REMEDY
● Reread the barcode. If this does not work, check the barcode header and terminator.
718 VS: Unknown message code
CAUSE
● Software error
REMEDY
● Inform Siemens Service; possibly reboot.
719 VS: Error during system call look
CAUSE
● Software error
REMEDY
● Inform Siemens Service; possibly reboot.
720 VS: File could not be opened
CAUSE
● File does not exist in the station computer
REMEDY
● Reinstall software
721 VS: Error in fiducial data
CAUSE
● Fiducial data erroneous; obsolete ICOS version
REMEDY
● Reset ICOS, update eproms