Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
75
768 No data received from PCB barcode reader
CAUSE
● PCB barcode reader not responding.
REMEDY
● Check PCB barcode reader.
769 Barcode too long, cut off!
CAUSE
● The maximum permissible length of the board barcode is 25 characters, of the component 20
characters; a longer barcode was received, but was cut short.
REMEDY
● The machine carries on working with the shortened barcode.
770 BL: unexpected input
CAUSE
● System error
REMEDY
● If possible, ignore.
771 VS: Communication between SR and MC defective
CAUSE
● Software error
REMEDY
● Reboot, if occurs repeatedly inform Siemens Service.
772 EH: received CODE unknown
CAUSE
● Incorrect message to task EH.
REMEDY
● If possible, ignore.
773 EH: received IDENT unknown
CAUSE
● Incorrect message to task EH.
REMEDY
● If possible, ignore.
774 EH: MC sending too many error messages (> F_FM_MAX)
CAUSE
● Error handling can receive a maximum of 200 error messages at the same time from the machine
controller.
REMEDY
● The error messages > 200 are discarded.
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
76
776 AKT: Error during system call ALOC
CAUSE
● No memory allocated to Task T_AKT.
REMEDY
● Reboot.
777 AKT: Incorrect input
CAUSE
● Task AKT has received unknown message.
REMEDY
● If possible, ignore, otherwise reboot.
778 AKT: Wrong data from data preparation
CAUSE
● Data preparation sending incorrect "AKTUELL.MA" format to task T_AKT.
REMEDY
● System error, reboot.
779 LRR: Undefined operation with and without LC
CAUSE
● The station computer receives a message from the line computer, but it was input at station com-
puter as "without LC".
REMEDY
● Input mode "with LC" at the station computer.
780 LRR: Undefined error in LC reception
CAUSE
● Error when receiving via IEC bus.
REMEDY
● Reboot.
781 LRR: No memory available
CAUSE
● Memory in station computer is fragmented.
REMEDY
● Reboot.
782 LRR: Defective or incomplete telegram from LC
CAUSE
● Unknown telegram from the line computer (may be incomplete)
REMEDY
● Respecify placement program in the line computer.
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
77
783 LRR: Error during data transm. via IEC bus (LISTEN)
CAUSE
● IEC bus disturbed
REMEDY
● Reboot line and station computers.
784 LRR: Error during system call
CAUSE
● System error
REMEDY
● Reboot.
785 No version indicated in table program
CAUSE
● Obsolete table program (TISCH.HEX)
REMEDY
● Update TISCH.HEX.
786 BO: Cannot initialize text pointer (lmbx/)
CAUSE
● System error when initializing text for task with the mailbox ID lmbx
REMEDY
● Reset system
787 TA: Error while writing to disk
CAUSE
● The file from the "Test output" task cannot be written to disk.
REMEDY
● Check the hardware (hard disk): is the hard disk full ? Can the corresponding directory be found ?
788 TA: Error in aloc
CAUSE
● No memory assigned.
REMEDY
● System error; reset.
789 BO: No text file name in text configuration file
CAUSE
● Error when reading the text file name from the file C:\TEXTE\SITXT_L.CFG
REMEDY
● Check text file and name in C:\TEXTE\SITXT_L.CFG.