Error Messages Short Reference SIPLACE 80 S-15/F3/G 03/99 Issue Software Version SR.010.x x 120 1 192 Glue spot check: error in me asurement results CAUSE ● Possibly incorrect Eprom version; otherwise software error REME…
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
119
1185 Z-axis, GU3: Bero not released when axis at bottom
CAUSE
● Z-axis is not moving downwards (sluggish); the bero is defective or set incorrectly
REMEDY
● Check the mechanism; check the bero; check the incremental transducer.
1186 Pressure build-up faulty
CAUSE
● The glue cartridge is missing; the compressed air supply to the dispenser unit is inadequate;
the valve (actuation) is defective
REMEDY
● Insert cartridge; check the compressed air supply, hoses, valve
1187 Pressure reduction faulty
CAUSE
● The venting valve (actuation) is defective
REMEDY
● Check the valve and hoses
1188 Glue spot check: error during meas. description generation
CAUSE
● Target diameter of the glue spots in the VKL file are outside the permitted range (0 < or < 3 mm)
Camera data (MA data) conversion factor pixels => µm erroneous
REMEDY
● Check data
1189 Glue spot check: error during measurement description loading
CAUSE
● Transmission error with the MVS vision system; possibly incorrect Eprom version
REMEDY
● Check Eprom version
1190 Glue spot check: error during visualization of results
CAUSE
● Transmission error with MVS vision system
REMEDY
● Check vision system
1191 Glue spot check: measurements start error
CAUSE
● Transmission error with MVS vision system
REMEDY
● Check vision system
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
120
1192 Glue spot check: error in measurement results
CAUSE
● Possibly incorrect Eprom version; otherwise software error
REMEDY
● Check Eprom version
1193 Glue spots too large for calculating volume adaption
CAUSE
● The size of glue spots is outside the control range for volume adaption (-5....+5); incorrect gluing
station configuration
REMEDY
● Check process parameters: nozzle diameter, spacer, temperature;
check gluing station configuration
1194 Glue spot check: no evaluation due to low qual.
CAUSE
● The shape or contrast of the glue spot was not good enough for the glue spot check.
REMEDY
● Check the gluing needle (defective, dirty).
The glue is leaving threads (check glue temperature)
Color of the glue is not satisfactory (for example, white glue), leading to poor contrast with the
glue scraper roller where the glue spot check is made.
1195 Glue spots too small for calculating volume adaption
CAUSE
● The size of glue spots is outside the control range for volume adaption (-5....+5); incorrect gluing
station configuration
REMEDY
● Check process parameters: nozzle diameter, spacer, temperature;
check gluing station configuration
1196 Dots of glue too large
CAUSE
● Glue dot size is outside correction range.
TO RECTIFY
● Check glue nozzle and spacer. Replace glue cartridge. Check glue characteristics.
1197 Dots of glue too small
CAUSE
● Glue dot size is outside correction range.
TO RECTIFY
● Check glue nozzle and spacer and clean glue nozzle. Replace glue cartridge. Check glue charac-
teristics.