00191494-01.pdf - 第24页

Error Messages Short Reference SIPLACE 80 S-15/F3/G 03/99 Issue Software Version SR.010.x x 22 238 Stopper jam during retraction CAUSE ● Compressed air lacking; back pressure too high; sto pper defective. REMEDY ● Check …

100%1 / 124
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
21
231 No PCB on the input conveyor
CAUSE
The PCB board was removed while being transported onto the central conveyor; sensor defec-
tive.
REMEDY
Under the menu "Transportation error" continue placement, place board on input conveyor; fit
new sensor.
232 The lifting table cannot be moved downwards
CAUSE
Beros defective; cutout triggered.
REMEDY
fit new Beros; close lifting table cutout.
233 Command to coplanarity is not complete
CAUSE
Package form data, set-up erroneous.
REMEDY
Re-assign set-up, repeat measurement.
234 The lifting table cannot be moved upwards
CAUSE
Beros defective; cutout triggered.
REMEDY
Fit new Beros; close lifting table cutout.
235 Center conveyor light barrier is not released
CAUSE
PCB board jamming in the central conveyor; sensor defective.
REMEDY
Correct the jamming; fit new sensor.
236 PCB does not reach the center conveyor
CAUSE
PCB board jamming in the center conveyor; sensor defective.
REMEDY
Correct the jamming; fit new sensor.
237 Stopper jam during extension
CAUSE
Compressed air lacking; back pressure too high; stopper defective.
REMEDY
Check compressed air; adjust back pressure; replace stopper.
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
22
238 Stopper jam during retraction
CAUSE
Compressed air lacking; back pressure too high; stopper defective.
REMEDY
Check compressed air; adjust back pressure; replace stopper.
239 Component description of coplanarity is not complete
CAUSE
Package form data erroneous.
REMEDY
Check package form data and respecify set-up.
240 Command data format to coplanarity is invalid
CAUSE
Package form data, set-up, cluster erroneous.
REMEDY
Check and respecify package form data, set-up, cluster.
241 Coplanarity tolerance is zero
CAUSE
Coplanarity tolerance (max. component height tolerance) in the set-up for the placement positi-
ons of the circuit image is zero.
REMEDY
Increase coplanarity tolerance (max. component height tolerance) and respecify set-up and clu-
ster.
242 No PCB on the center conveyor
CAUSE
Transportation onto output conveyor was started under single functions although there is no
board on the center conveyor; sensor in the center conveyor defective.
REMEDY
Only start transportation onto the output conveyor under single functions when there is a board
on the center conveyor; fit new sensor.
243 PCB does not reach the output conveyor
CAUSE
PCB board jamming in the center conveyor; sensor defective.
REMEDY
Correct the jamming; fit new sensor.
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
23
244 Center conveyor occupied
CAUSE
When the function "Board to center conveyor" started there already was a PCB board on the cen-
ter conveyor; sensor defective.
When the belt speed was set the center conveyor was occupied.
REMEDY
Remove the PCB board; fit new sensor.
245 Output conveyor occupied
CAUSE
When the function "Board to output conveyor" started there already was a PCB board on the out-
put conveyor; sensor of output conveyor defective.
When the belt speed was set output conveyor was occupied.
REMEDY
Remove the PCB board; fit new sensor.
246 BERO of left table side is not activated
CAUSE
Bero is not covered.
REMEDY
Check Bero.
247 Error in axis programming (left table side)
CAUSE
Bero of the left table side defective; axis could not be moved.
REMEDY
Check Bero; reboot.
248 BERO of left table side responding constantly
CAUSE
Bero constantly covered.
REMEDY
Check Bero.
249 Width adjustment at limit switch maximum width
CAUSE
Width adjustment moved up to the limit switch; limit switch defective.
REMEDY
Move width adjustment in other direction; fit new limit switch.
250 Width adjustment at limit switch minimum width
CAUSE
Width adjustment moved up to the limit switch; limit switch defective.
REMEDY
Move width adjustment in other direction; fit new limit switch.