80
804 BO: POOL cannot be given back (length);
CAUSE
A requested memory area can no longer be returned, system error.
REMEDY
Reset station.
805 BO: Message cannot be sent (state/code)
CAUSE
Error during system call "send" or not enough memory available.
REMEDY
Reset station.
806 NF: unexpected input
CAUSE
System error
REMEDY
If possible, ignore
807 KLKONF: System error during initialization
CAUSE
Software error in glueing configuration task
REMEDY
Reboot
808 KLKONF: System error during memory request
CAUSE
Software error in glueing configuration task during memory request
REMEDY
Reboot
809 KLKONF: System error during give back memory
CAUSE
Software error in glueing configuration task during give back of memory
REMEDY
Reboot
810 KLKONF: System error during send message
CAUSE
Software error in glueing configuration task during send message
REMEDY
Reboot
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
81
811 KLKONF: Incorrect input
CAUSE
Software error in glueing configuration task; Incorrect message received
REMEDY
Reboot
812 KLKONF: Invalid input data
CAUSE
Software error in glueing configuration task; Incorrect data received from data preparation
REMEDY
Reboot; get the data organized
813 WARNING: Glue data from file ".ZKL" invalid
CAUSE
1. No *.ZKL can be found (with glueing parameters which have not yet been manipulated).
2. Data from "ZKL" incorrect.
REMEDY
To 1. Not an error
To 2. Delete *.ZKL, manipulate, then a new *.ZKL will be created.
814 Glueing data cannot be modified
CAUSE
Software error
REMEDY
Reboot
815 DP: Incorrect operating system call
CAUSE
Software error
REMEDY
Siemens Service should be notified.
816 DP: No LC command in service without LC
CAUSE
Machine in "service without line computer" but all the same command received via IEC bus.
REMEDY
Machines and line configuration should be checked.
817 DP: Set-up without valid machine data
CAUSE
Incorrect data supply from the line computer.
REMEDY
Data supply from the line computer should be checked.
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
82
818 DP: Cluster without valid set-up data
CAUSE
Incorrect data supply from the line computer.
REMEDY
Data supply from the line computer should be checked.
819 DP: Package form without valid set-up data
CAUSE
Incorrect data supply from the line computer.
REMEDY
Data supply from the line computer should be checked.
820 DP: Delete package form without valid set-up data
CAUSE
Incorrect data supply from the line computer.
REMEDY
Data supply from the line computer should be checked.
821 DP: Set-up and cluster without valid machine data
CAUSE
Incorrect data supply from the line computer.
REMEDY
Data supply from the line computer should be checked.
822 DP: Error in the data supply from LC
CAUSE
Incorrect data supply from the line computer.
REMEDY
Data supply from the line computer should be checked.
823 DP: Invalid request from vision task
CAUSE
Software error in operation DP with vision system
REMEDY
Reboot
824 DP: Fiducial telegram in mixed line not allowed
CAUSE
Fiducial telegram sent to SIPLACE from line computer in mixed line.
REMEDY
Check configuration.