00191494-01.pdf - 第68页
Error Messages Short Reference SIPLACE 80 S-15/F3/G 03/99 Issue Software Version SR.010.x x 66 702 BO: Mouse code not impleme nted (mouse code) CAUSE ● BO has received an un known message. REMEDY ● Write down error messa…
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
65
694 Incorrect nozzle length
CAUSE
● No nozzle present.
The nozzle is seated incorrectly.
The wrong nozzle type has been set up.
REMEDY
● Make sure the head is fitted with the correct nozzle.
Check the seating of the nozzle.
696 Warning: Break to DP1-axis
CAUSE
● Internal program run error when the DP1-axis is overshooting.
REMEDY
● Confirm the error message.
If this error occurs frequently, please notify Siemens Service
697 Warning: Break to DP2-axis
CAUSE
● Internal program run error when the DP1-axis is overshooting.
REMEDY
● Confirm the error message.
If this error occurs frequently, please notify Siemens Service
698 Error during break to DP1-axis: boot!
CAUSE
● It is not possible to confirm error message 696 with respect to the internal program run error.
REMEDY
● Reboot the station. Notify Siemens Service.
699 Error during break to DP2-axis: boot!
CAUSE
● It is not possible to confirm error message 697 with respect to the internal program run error.
REMEDY
● Reboot the station. Notify Siemens Service.
701 BO: Info received is not a message (ident/code)
CAUSE
● BO has received a message which is not actually classified as a message. The details (ident
code) concern the contents of the message. These values are given in (Info1/Info2).
REMEDY
● Write down error message giving the complete error message and under what conditions the
error occurred. With the machine at standstill, reset the machine.
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
66
702 BO: Mouse code not implemented (mouse code)
CAUSE
● BO has received an unknown message.
REMEDY
● Write down error message giving the complete error message and stating under what conditions
the error occurred. With the machine at standstill, reset the machine.
703 BO: CODE received unknown (code/state)
CAUSE
● BO has received unknown or unexpected message.
REMEDY
● Write down error message giving the complete error message and stating under what conditions
the error occurred. With the machine at standstill, reset the machine.
704 Text table could not be initialized at first attempt
CAUSE
● There is an error in the text table (text too long, for example)
REMEDY
● It is not necessary to stop operation. Please notify Siemens Service.
705 BO: Unknown element type in dialogue field (typ)
CAUSE
● Error in the data of the BO
REMEDY
● Write down error message giving the complete error message and stating under what conditions
the error occurred. With the machine at standstill, reset the machine.
706 BO: ID type unknown in menu (menuid_typ)
CAUSE
● Error in the data of the BO
REMEDY
● Write down error message giving the complete error message and stating under what conditions
the error occurred. With the machine at standstill, reset the machine.
707 CRDL 1 configured without mechanical centering
CAUSE
● Despite the CRDL tester, the mechanical centering station has not been configured (tester wit-
hout mechanical centering station is not possible)
REMEDY
● Correct the configuration in the line computer for this station.
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
67
708 CRDL 2 configured without mechanical centering
CAUSE
● Despite the CRDL tester, the mechanical centering station has not been configured (tester wit-
hout mechanical centering station is not possible)
REMEDY
● Correct the configuration in the line computer for this station.
709 BO: Event flag ID unknown (flag id)
CAUSE
● System error during system call SVC-Look for event flag group of the keyboard task
REMEDY
● When the machine is at a standstill, reset the machine.
710 BO: Error in RIO. HSFS_XREAD (sts)
CAUSE
● System error during keyboard input.
REMEDY
● When the machine is at a standstill, reset the machine.
711 BO: 1st state byte HSFS_XREAD (status[0])
CAUSE
● System error during keyboard input.
REMEDY
● When the machine is at a standstill, reset the machine.
712 BO: Error in RIO POLL_XBUF (sts)
CAUSE
● System error during keyboard input.
REMEDY
● When the machine is at a standstill, reset the machine.
713 BO: 1st status byte POLL_XBUF (status[0])
CAUSE
● System error during keyboard input.
REMEDY
● When the machine is at a standstill, reset the machine.
714 NF: no memory available
CAUSE
● System error
REMEDY
● Reboot