00191494-01.pdf - 第13页

Short Reference SIPLACE 80 S-15/F3/G Error Messages 03/99 Issue Software Version SR.010.x x 11 125 Coplanarity: clamping of Z-axis doe s not work CAUSE ● Clamping reacts too slow; clam ping is defective. REMEDY ● Operate…

100%1 / 124
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
10
102 Quality too low during optical centering
CAUSE
Parameters for optical centering erroneous.
REMEDY
Check the package form in the components manipulator.
103 Spacing of a pin group out of tolerance
CAUSE
Bent terminal pin; pitch error limit defined too small.
REMEDY
Check components; increase pitch error limit in the package form editor.
104 Component angle outside of tolerance
CAUSE
Angular positioning deviation of the component on the nozzle too great; angular positioning tole-
rance defined too small.
REMEDY
Improve pick-up; increase angular positioning tolerance.
121 Peak offset: no result
CAUSE
Component terminal pin bent.
REMEDY
Check quality of the components.
122 Coplanarity module cannot be initialized
CAUSE
Coplanarity module not plugged in; configuration jumper incorrectly set
REMEDY
Plug in module; correct jumper.
123 Coplan.: Data value outside of range
CAUSE
Error in cluster or set-up: PF file faulty
REMEDY
Check data for coplanarity in cluster and set-up; check PF data.
124 Vacuum reduction at placem. stat. too slow
CAUSE
During placement of a component the vacuum does not reduce fast enough;
forced air not present; forced air defective.
REMEDY
Check forced air; check forced air valve.
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
11
125 Coplanarity: clamping of Z-axis does not work
CAUSE
Clamping reacts too slow; clamping is defective.
REMEDY
Operate clamping repeatedly; check clamping.
126 Unknown telegram to table
CAUSE
Obsolete
TISCH.HEX
file.
REMEDY
Update
TISCH.HEX
file.
129 Communication table-feeder interrupted
CAUSE
Since the last booting, the connection with the conveyor has been interrupted; the conveyor is not
plugged in; cable is defective.
REMEDY
Plug in the conveyor; check the cable.
130 Communication table-feeder disturbed
CAUSE
Communication between table and conveyor is interrupted from time to time; the cable is defec-
tive; the conveyor has been unplugged.
REMEDY
Plug in the conveyor; check the cable and plug.
132 Foil torn
CAUSE
The cover foil is torn; the foil removal force has been set incorrectly; the conveyor is defective.
REMEDY
Repair the foil; adjust removal springs; replace the conveyor.
133 Foil not removed
CAUSE
The cover foil is not being stripped off; the foil removal force has been set incorrectly; the con-
veyor is defective.
REMEDY
Pull off the foil by hand; set removal spring
134 Transport in feeder disturbed
CAUSE
Tape backing up; the conveyor is defective
REMEDY
Remove tape back-up; replace the conveyor
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
12
137 Not enough garages in changer magazine for nozzle return. SP
CAUSE
Nozzles should be returned
With optical garage check: all garages were checked with the board camera and are occupied.
Without optical garage check: there are not enough empty garages available for the nozzles to be
returned.
REMEDY
Takes place automatically: all nozzles which could not be returned are rejected.
138 Insuff. number of nozzles in changer magazine SP to pick up
CAUSE
Nozzles are to be picked up
With optical garage check: All garages have been checked with the board camera and are empty
Without optical garage check: One or more garages of the required nozzle type is empty.
REMEDY
The corresponding magazines must be set full via the menu.
139 No cluster available for nozzle pick-up SP
CAUSE
No cluster has been specified as specified selection.
REMEDY
Specifiy placement program in the line computer.
140 Nozzle-changer SP head cannot be unlocked
CAUSE
Key plate for locking the nozzle-changer magazine cannot be unlocked.
The plate is jamming mechanically, due to components etc.
Incorrect compressed air setting for the actuating cylinder; lacking air pressure;
the cylinder or valve is defective.
REMEDY
Correction of the above causes
141 Nozzle-changer SP head cannot be locked
CAUSE
Key plate for locking the nozzle-changer magazine cannot be unlocked.
The plate is jamming mechanically, due to components etc.
Incorrect compressed air setting for the actuating cylinder; lacking air pressure;
the cylinder or valve is defective.
REMEDY
Correction of the above causes
142 Communication with vision system during nozzle check faulty
CAUSE
Communication with the vision system is faulty.
REMEDY
Switch the system on and off (reset); notify Siemens Service Department.