00191494-01.pdf - 第13页
Short Reference SIPLACE 80 S-15/F3/G Error Messages 03/99 Issue Software Version SR.010.x x 11 125 Coplanarity: clamping of Z-axis doe s not work CAUSE ● Clamping reacts too slow; clam ping is defective. REMEDY ● Operate…
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
10
102 Quality too low during optical centering
CAUSE
● Parameters for optical centering erroneous.
REMEDY
● Check the package form in the components manipulator.
103 Spacing of a pin group out of tolerance
CAUSE
● Bent terminal pin; pitch error limit defined too small.
REMEDY
● Check components; increase pitch error limit in the package form editor.
104 Component angle outside of tolerance
CAUSE
● Angular positioning deviation of the component on the nozzle too great; angular positioning tole-
rance defined too small.
REMEDY
● Improve pick-up; increase angular positioning tolerance.
121 Peak offset: no result
CAUSE
● Component terminal pin bent.
REMEDY
● Check quality of the components.
122 Coplanarity module cannot be initialized
CAUSE
● Coplanarity module not plugged in; configuration jumper incorrectly set
REMEDY
● Plug in module; correct jumper.
123 Coplan.: Data value outside of range
CAUSE
● Error in cluster or set-up: PF file faulty
REMEDY
● Check data for coplanarity in cluster and set-up; check PF data.
124 Vacuum reduction at placem. stat. too slow
CAUSE
● During placement of a component the vacuum does not reduce fast enough;
forced air not present; forced air defective.
REMEDY
● Check forced air; check forced air valve.
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
11
125 Coplanarity: clamping of Z-axis does not work
CAUSE
● Clamping reacts too slow; clamping is defective.
REMEDY
● Operate clamping repeatedly; check clamping.
126 Unknown telegram to table
CAUSE
● Obsolete
TISCH.HEX
file.
REMEDY
● Update
TISCH.HEX
file.
129 Communication table-feeder interrupted
CAUSE
● Since the last booting, the connection with the conveyor has been interrupted; the conveyor is not
plugged in; cable is defective.
REMEDY
● Plug in the conveyor; check the cable.
130 Communication table-feeder disturbed
CAUSE
● Communication between table and conveyor is interrupted from time to time; the cable is defec-
tive; the conveyor has been unplugged.
REMEDY
● Plug in the conveyor; check the cable and plug.
132 Foil torn
CAUSE
● The cover foil is torn; the foil removal force has been set incorrectly; the conveyor is defective.
REMEDY
● Repair the foil; adjust removal springs; replace the conveyor.
133 Foil not removed
CAUSE
● The cover foil is not being stripped off; the foil removal force has been set incorrectly; the con-
veyor is defective.
REMEDY
● Pull off the foil by hand; set removal spring
134 Transport in feeder disturbed
CAUSE
● Tape backing up; the conveyor is defective
REMEDY
● Remove tape back-up; replace the conveyor
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
12
137 Not enough garages in changer magazine for nozzle return. SP
CAUSE
● Nozzles should be returned ⇒
With optical garage check: all garages were checked with the board camera and are occupied.
Without optical garage check: there are not enough empty garages available for the nozzles to be
returned.
REMEDY
● Takes place automatically: all nozzles which could not be returned are rejected.
138 Insuff. number of nozzles in changer magazine SP to pick up
CAUSE
● Nozzles are to be picked up ⇒
With optical garage check: All garages have been checked with the board camera and are empty
Without optical garage check: One or more garages of the required nozzle type is empty.
REMEDY
● The corresponding magazines must be set full via the menu.
139 No cluster available for nozzle pick-up SP
CAUSE
● No cluster has been specified as specified selection.
REMEDY
● Specifiy placement program in the line computer.
140 Nozzle-changer SP head cannot be unlocked
CAUSE
● Key plate for locking the nozzle-changer magazine cannot be unlocked.
The plate is jamming mechanically, due to components etc.
Incorrect compressed air setting for the actuating cylinder; lacking air pressure;
the cylinder or valve is defective.
REMEDY
● Correction of the above causes
141 Nozzle-changer SP head cannot be locked
CAUSE
● Key plate for locking the nozzle-changer magazine cannot be unlocked.
The plate is jamming mechanically, due to components etc.
Incorrect compressed air setting for the actuating cylinder; lacking air pressure;
the cylinder or valve is defective.
REMEDY
● Correction of the above causes
142 Communication with vision system during nozzle check faulty
CAUSE
● Communication with the vision system is faulty.
REMEDY
● Switch the system on and off (reset); notify Siemens Service Department.