00191494-01.pdf - 第101页
Short Reference SIPLACE 80 S-15/F3/G Error Messages 03/99 Issue Software Version SR.010.x x 99 1031 Z-axis; GU2: Position control does not work CAUSE ● The position control of the ax is is not working properly; ma chine …
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
98
1024 yk-axis: deactivated
CAUSE
● Axis has been deactivated at the axis board (servo)
REMEDY
● Switch on the axis at the axis card
1025 Z-axis; GU1: deactivated
CAUSE
● Axis has been deactivated at the axis board (servo)
REMEDY
● Switch on the axis at the axis card
1026 Z-axis; GU2: deactivated
CAUSE
● Axis has been deactivated at the axis board (servo)
REMEDY
● Switch on the axis at the axis card
1027 Z-axis; GU3: deactivated
CAUSE
● Axis has been deactivated at the axis board (servo)
REMEDY
● Switch on the axis at the axis card
1028 xk-axis: Position control does not work
CAUSE
● The position control of the axis is not working properly; machine data are not correct
REMEDY
● Switch off the machine (reset), check axis for stiffness of running; check the machine data
1029 yk-axis: Position control does not work
CAUSE
● The position control of the axis is not working properly; machine data are not correct
REMEDY
● Switch off the machine (reset), check axis for stiffness of running; check the machine data
1030 Z-axis; GU1: Position control does not work
CAUSE
● The position control of the axis is not working properly; machine data are not correct
REMEDY
● Switch off the machine (reset), check axis for stiffness of running; check the machine data
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
99
1031 Z-axis; GU2: Position control does not work
CAUSE
● The position control of the axis is not working properly; machine data are not correct
REMEDY
● Switch off the machine (reset), check axis for stiffness of running; check the machine data
1032 Z-axis; GU3: Position control does not work
CAUSE
● The position control of the axis is not working properly; machine data are not correct
REMEDY
● Switch off the machine (reset), check axis for stiffness of running; check the machine data
1033 X-axis: deactivated
CAUSE
● Axis has been deactivated at the axis board (servo)
REMEDY
● Switch on the axis at the axis card
1034 Y-axis: deactivated
CAUSE
● Axis has been deactivated at the axis board (servo)
REMEDY
● Switch on the axis at the axis card
1035 xk-axis: deactivated
CAUSE
● Axis has been deactivated at the axis board (servo)
REMEDY
● Switch on the axis at the axis card
1036 yk-axis: deactivated
CAUSE
● Axis has been deactivated at the axis board (servo)
REMEDY
● Switch on the axis at the axis card
1037 Z-axis; GU1: deactivated
CAUSE
● Axis has been deactivated at the axis board (servo)
REMEDY
● Switch on the axis at the axis card
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
100
1038 Z-axis; GU2: deactivated
CAUSE
● Axis has been deactivated at the axis board (servo)
REMEDY
● Switch on the axis at the axis card
1039 Z-axis; GU3: deactivated
CAUSE
● Axis has been deactivated at the axis board (servo)
REMEDY
● Switch on the axis at the axis card
1040 X-axis: Timeout
CAUSE
● Axis does not reach position within the specified time; axis setting is not correct; machine data not
correct; drive motor, tachometer, incremental encoder, servo-amplifier defective;
mechanism is jamming
REMEDY
● Check the axis calibration; check machine data; or check the components; if necessary, replace;
check the mechanism;
1041 Y-axis: Timeout
CAUSE
● Axis does not reach position within the specified time; axis setting is not correct; machine data not
correct; drive motor, tachometer, incremental encoder, servo-amplifier defective;
mechanism is jamming
REMEDY
● Check the axis calibration; check machine data; or check the components; if necessary, replace;
check the mechanism;
1042 xk-axis: Timeout
CAUSE
● Axis does not reach position within the specified time; axis setting is not correct; machine data not
correct; drive motor, tachometer, incremental encoder, servo-amplifier defective;
mechanism is jamming
REMEDY
● Check the axis calibration; check machine data; or check the components; if necessary, replace;
check the mechanism;
1043 yk-axis: Timeout
CAUSE
● Axis does not reach position within the specified time; axis setting is not correct; machine data not
correct; drive motor, tachometer, incremental encoder, servo-amplifier defective;
mechanism is jamming
REMEDY
● Check the axis calibration; check machine data; or check the components; if necessary, replace;
check the mechanism;