Short Reference SIPLACE 80 S-15/F3/G Error Messages 03/99 Issue Software Version SR.010.x x 21 231 No PCB on the input conveyor CAUSE ● The PCB board was removed while being transported on to the central conveyor; sensor…
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
20
221 Programmed position of X-axis outside travel range
CAUSE
● Error in the local machine data (location fiducials).
REMEDY
● Check the fiducial data in the machine data.
222 Programmed position of Y-axis outside travel range
CAUSE
● Error in the local machine data (location fiducials).
REMEDY
● Check the fiducial data in the machine data.
226 Vacuum of pick-up circuit not within range
CAUSE
● Segments dirty; vacuum not working properly; limits specified too low; vacuum circuit defective.
REMEDY
● Maintain segments; check vacuum; extend limits; check vacuum circuit.
227 Vacuum of reject circuit not within range
CAUSE
● Segments dirty; vacuum not working properly; limits specified too low; vacuum circuit defective.
REMEDY
● Maintain segments; check vacuum; extend limits; check vacuum circuit.
228 Interface signals to the preceding station incorrect
CAUSE
● Interface line not connected; cable defective; interface boards defective.
REMEDY
● Check signal path, replace defective assemblies.
229 The input conveyor light barrier is not covered
CAUSE
● PCB board was removed while program was executing; PCB board jamming; sensor defective.
REMEDY
● Correct the jamming; fit new sensor.
230 The input conveyor light barrier is not released
CAUSE
● PCB board jamming; sensor defective.
REMEDY
● Correct the jamming; fit new sensor.
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
21
231 No PCB on the input conveyor
CAUSE
● The PCB board was removed while being transported onto the central conveyor; sensor defec-
tive.
REMEDY
● Under the menu "Transportation error" continue placement, place board on input conveyor; fit
new sensor.
232 The lifting table cannot be moved downwards
CAUSE
● Beros defective; cutout triggered.
REMEDY
● fit new Beros; close lifting table cutout.
233 Command to coplanarity is not complete
CAUSE
● Package form data, set-up erroneous.
REMEDY
● Re-assign set-up, repeat measurement.
234 The lifting table cannot be moved upwards
CAUSE
● Beros defective; cutout triggered.
REMEDY
● Fit new Beros; close lifting table cutout.
235 Center conveyor light barrier is not released
CAUSE
● PCB board jamming in the central conveyor; sensor defective.
REMEDY
● Correct the jamming; fit new sensor.
236 PCB does not reach the center conveyor
CAUSE
● PCB board jamming in the center conveyor; sensor defective.
REMEDY
● Correct the jamming; fit new sensor.
237 Stopper jam during extension
CAUSE
● Compressed air lacking; back pressure too high; stopper defective.
REMEDY
● Check compressed air; adjust back pressure; replace stopper.
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
22
238 Stopper jam during retraction
CAUSE
● Compressed air lacking; back pressure too high; stopper defective.
REMEDY
● Check compressed air; adjust back pressure; replace stopper.
239 Component description of coplanarity is not complete
CAUSE
● Package form data erroneous.
REMEDY
● Check package form data and respecify set-up.
240 Command data format to coplanarity is invalid
CAUSE
● Package form data, set-up, cluster erroneous.
REMEDY
● Check and respecify package form data, set-up, cluster.
241 Coplanarity tolerance is zero
CAUSE
● Coplanarity tolerance (max. component height tolerance) in the set-up for the placement positi-
ons of the circuit image is zero.
REMEDY
● Increase coplanarity tolerance (max. component height tolerance) and respecify set-up and clu-
ster.
242 No PCB on the center conveyor
CAUSE
● Transportation onto output conveyor was started under single functions although there is no
board on the center conveyor; sensor in the center conveyor defective.
REMEDY
● Only start transportation onto the output conveyor under single functions when there is a board
on the center conveyor; fit new sensor.
243 PCB does not reach the output conveyor
CAUSE
● PCB board jamming in the center conveyor; sensor defective.
REMEDY
● Correct the jamming; fit new sensor.