811 KLKONF: Incorrect input
CAUSE
● Software error in glueing configuration task; Incorrect message received
REMEDY
● Reboot
812 KLKONF: Invalid input data
CAUSE
● Software error in glueing configuration task; Incorrect data received from data preparation
REMEDY
● Reboot; get the data organized
813 WARNING: Glue data from file ".ZKL" invalid
CAUSE
● 1. No *.ZKL can be found (with glueing parameters which have not yet been manipulated).
2. Data from "ZKL" incorrect.
REMEDY
● To 1. Not an error
To 2. Delete *.ZKL, manipulate, then a new *.ZKL will be created.
814 Glueing data cannot be modified
CAUSE
● Software error
REMEDY
● Reboot
815 DP: Incorrect operating system call
CAUSE
● Software error
REMEDY
● Siemens Service should be notified.
816 DP: No LC command in service without LC
CAUSE
● Machine in "service without line computer" but all the same command received via IEC bus.
REMEDY
● Machines and line configuration should be checked.
817 DP: Set-up without valid machine data
CAUSE
● Incorrect data supply from the line computer.
REMEDY
● Data supply from the line computer should be checked.
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
82
818 DP: Cluster without valid set-up data
CAUSE
● Incorrect data supply from the line computer.
REMEDY
● Data supply from the line computer should be checked.
819 DP: Package form without valid set-up data
CAUSE
● Incorrect data supply from the line computer.
REMEDY
● Data supply from the line computer should be checked.
820 DP: Delete package form without valid set-up data
CAUSE
● Incorrect data supply from the line computer.
REMEDY
● Data supply from the line computer should be checked.
821 DP: Set-up and cluster without valid machine data
CAUSE
● Incorrect data supply from the line computer.
REMEDY
● Data supply from the line computer should be checked.
822 DP: Error in the data supply from LC
CAUSE
● Incorrect data supply from the line computer.
REMEDY
● Data supply from the line computer should be checked.
823 DP: Invalid request from vision task
CAUSE
● Software error in operation DP with vision system
REMEDY
● Reboot
824 DP: Fiducial telegram in mixed line not allowed
CAUSE
● Fiducial telegram sent to SIPLACE from line computer in mixed line.
REMEDY
● Check configuration.
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
83
825 DP: Unknown message received
CAUSE
● Software error
REMEDY
● Reboot
826 DP: Error while updating the int. global data
CAUSE
● Software error
REMEDY
● Reboot
827 DP: Error while creating int. list for pack. form data
CAUSE
● Software error
REMEDY
● Reboot
828 DP: No more storing capacity available
CAUSE
● Station computer has no more memory capacity left
REMEDY
● Data too large (set-up, cluster, ....); reboot
829 DP: Error in local communication
CAUSE
● Software error
REMEDY
● Reboot
830 DP: Error during equipment cataloging
CAUSE
● Software error
REMEDY
● Reboot
831 DP: Dynam. equipment cannot be generated
CAUSE
● Software error
REMEDY
● Reboot