00191494-01.pdf - 第72页

Error Messages Short Reference SIPLACE 80 S-15/F3/G 03/99 Issue Software Version SR.010.x x 70 729 VS: Upload data incorrect CAUSE ● Obsolete MVS software , MVS error . REMEDY ● Reboot; update eprom s (MVS). 730 NF: soft…

100%1 / 124
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
69
722 VS: Error during memory request
CAUSE
Software error
REMEDY
Reboot; inform Siemens Service.
723 VS: File could not be opened
CAUSE
File does not exist in the station computer (TISCH.HEX)
REMEDY
Reinstall software (possibly only TISCH.HEX)
724 VS: Error during memory request
CAUSE
Not enough memory available in the station computer
REMEDY
Reset station computer
725 VS: Error during memory release in VS load
CAUSE
Software error
REMEDY
Inform Siemens Service.
726 VS: Error in message reception
CAUSE
Software error
REMEDY
Inform Siemens Service; possibly reboot.
727 VS: Error in send function in SC
CAUSE
Software error
REMEDY
Inform Siemens Service; possibly reboot.
728 VS: Unknown state
CAUSE
Software error
REMEDY
Inform Siemens Service; possibly reboot.
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
70
729 VS: Upload data incorrect
CAUSE
Obsolete MVS software, MVS error.
REMEDY
Reboot; update eproms (MVS).
730 NF: software error
CAUSE
Incorrect message at NF (Info1)
REMEDY
If possible, ignore; possibly reboot.
731 NF: GLC NOK
CAUSE
Internal transmission error
REMEDY
Try again; if possible, ignore.
732 MA data: unknown spacer type
CAUSE
In aktuell.ma or *.vkl there is a spacer type which cannot be found in real.ma.
REMEDY
Establish consistency in the files aktuell.ma, *vkl and real.ma.
733 SF: unexpected input:
CAUSE
Incorrect message to single function (Info1), operator error during transition to single function or
fatal error handling ( start button not pressed )
REMEDY
If possible, ignore; possibly reboot.
734 SF: answer from wrong MC
CAUSE
System error
REMEDY
Reboot
735 SF: global communication not ok
CAUSE
Communication between machine controller and station computer disturbed.
REMEDY
Try communicating again.
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
71
736 GK: Error in local machine data
CAUSE
There are no real or current machine data on the hard disk; the machine data cannot be conver-
ted due to a structure error.
REMEDY
Write the MA data onto the hard disk properly.
737 GK: Error in machine data
CAUSE
The MA data (ideal) coming from the line computer cannot be converted.
REMEDY
The correct data format must be sent.
738 GK: Error in set-up data
CAUSE
The set-up data coming from the line computer cannot be converted.
REMEDY
The correct data format must be sent.
739 GK: Error in cluster data
CAUSE
The cluster data coming from the line computer cannot be converted.
REMEDY
The correct data format must be sent.
740 GK: Error in fiducial data
CAUSE
The fiducial data coming from the line computer cannot be converted.
REMEDY
The correct data format must be sent.
741 GK: Error in package form data
CAUSE
The package form data coming from the line computer cannot be converted.
REMEDY
The correct data format must be sent.
742 LRS: Timeout during transmission to line computer
CAUSE
Released through IEC bus
REMEDY
Reboot