00191494-01.pdf - 第62页

Error Messages Short Reference SIPLACE 80 S-15/F3/G 03/99 Issue Software Version SR.010.x x 60 546 WPC: Error in saved set-up. CAUSE ● At pick-up of the component division number not in the set-up; ch ecksum of the set-u…

100%1 / 124
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
59
539 WPC: Fault in lifting axis (servo or axis card)
CAUSE
Axis board of the lifting axis defective; Servo of the lifting axis defective.
REMEDY
Fit new axis board or servo board and inform Siemens Service.
540 WPC: Lifting axis at limit switch
CAUSE
Lifting axis at the limit switch; limit switch defective.
REMEDY
Release the brake of the lifting axis and push lifting axis away from limit switch; fit new limit
switch.
541 WPC: Axis error of lifting axis
CAUSE
Undefined reference point or type of positioning; undefined axis command; position outside the
travel range.
REMEDY
Reboot; inform Siemens Service.
542 WPC: Lifting axis servo released
CAUSE
Servo disabled at the axis board.
REMEDY
Switch servo back on at the axis board.
543 WPC: Control switched off.
CAUSE
Control of the component carriage failed; plugged connection faulty.
REMEDY
Check plugged connection and inform Siemens Service.
544 WPC: Protection at component table open.
CAUSE
Guard at the component carriage opened; protective switch or cable connection defective.
REMEDY
Close guard; fit new protective switch and check cable connection.
545 WPC: Error while transporting tray
CAUSE
When a tray is being supplied the "Tray ready" Bero is covered; the "Tray ready" Bero is defec-
tive; when a tray is being returned the "Tray in magazine" Bero is covered; the "Tray in magazine"
Bero is defective.
REMEDY
Check the "Tray ready" Bero and "Tray in magazine" Bero.
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
60
546 WPC: Error in saved set-up.
CAUSE
At pick-up of the component division number not in the set-up; checksum of the set-up erroneous.
REMEDY
Reboot and inform Siemens Service.
547 WPC: One tray of saved set-up missing
CAUSE
No tray present when changing levels; the "Tray in magazine" Bero is defective.
REMEDY
Fit new "Tray in magazine" Bero.
548 WPC: When returning tray, level occupied
CAUSE
Tray placed in travel range of the feed axis (when feed axis moved out);
the "Tray in magazine" Bero is defective.
REMEDY
Remove tray; fit new "Tray in magazine" Bero.
549 WPC: Tray has been taken out.
CAUSE
Ready tray was removed; the "Tray ready" Bero is defective.
REMEDY
Re-insert tray; fit new "Tray ready" Bero.
550 WPC: Take-over position already occupied
CAUSE
A tray already occupied the take-over position; the "Tray ready" Bero is defective.
REMEDY
Remove tray; fit new "Tray ready" Bero.
551 WPC: Tray in incorrect position or protection not closed properly.
CAUSE
Guard not correctly closed; tray positioned incorrectly; the "Lock against rotation " Bero is defec-
tive.
REMEDY
Close guard correctly; insert tray correctly; fit new "Lock against rotation" Bero.
552 WPC: Feed axis has touched protection.
CAUSE
The "Lock against rotation" Bero is defective; guard was opened during change procedure; tray
inserted incorrectly and driven against the guard.
REMEDY
Close guard; fit new "Lock against rotation" Bero; insert tray correctly.
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
61
553 Coplan.: Software error during system call RIO
CAUSE
Communication with the coplanarity module has been interrupted
REMEDY
Check the V-24 interface cable; check the jumper setting of the coplanarity module.
554 Communication between SR and MC interrupted
CAUSE
Hardware fault in a module (M18, M34) or a wiring fault.
REMEDY
Replace modules; check the wiring at the back of the control unit.
555 IC head nozzle changer option not set
CAUSE
The nozzle-changer was called without this option being set in the line computer.
REMEDY
Configure the nozzle-changer in the line computer.
556 Nozzle type not available
CAUSE
During nozzle changing or pick-up a nozzle type was demanded which lies outside the valid
range.
REMEDY
Check the cluster and set-up.
557 Nozzle type not in IC-head nozzle changer set-up
CAUSE
The nozzle type required was not included in the nozzle-changer set-up
REMEDY
Modify nozzle-changer set-up.
558 Error during MVS initialization via HS3L
CAUSE
Wiring of HS3L interface faulty; MVS card not inserted correctly in control unit.
REMEDY
Check HS3L wiring; check seating of the MVS card.
559 Data error in MC: optical centering indices incorrect
CAUSE
The job data are inconsistent.
REMEDY
Check the camera records in the REAL.MA file; check the job data (GF data) in the line computer.