Short Reference SIPLACE 80 S-15/F3/G Error Messages 03/99 Issue Software Version SR.010.x x 73 751 Data preparation : run error CAUSE ● If there was previously an erro r in the placement data (MK /GF/RU/NU files) all oth…
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
72
744 LRS: Command not in command list
CAUSE
● LR SEND incorrect command received
REMEDY
● If possible, ignore.
745 LRS: Conversion is not possible
CAUSE
● Could not convert data for line computer telegrams SABR/SBES.
REMEDY
● No
746 LRS: No communication with line computer
CAUSE
● IEC bus is "blocked"
REMEDY
● Reboot station and line computers.
747 DP: Data limits exceeded
CAUSE
● Incorrect date input
REMEDY
● Correct input date
748 DP: required equipment unknown
CAUSE
● Possibly the TASKS.CFG file has been changed, or there is a software fault
REMEDY
● Reboot with the supplied version of TASKS.CFG ; if necessary, notify Siemens Service.
749 No PCB barcode read
CAUSE
● Barcode reader has been activated but barcode was not recognized
REMEDY
● Make sure the barcode type is correct; make sure the mechanical distance is correct
750 Data preparation : internal error
CAUSE
● Not possible to write to station computer hard disk.
REMEDY
● Check disk; disk full?; files write-protected ? (check *.MA, *.GF, *.NU, *.RU)
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
73
751 Data preparation : run error
CAUSE
● If there was previously an error in the placement data (MK/GF/RU/NU files) all other telegrams
coming from the line computer will be discarded and in each case a message generated.
REMEDY
● Reboot station (a great deal of specialist knowledge is required for precise identification of this
fault).
752 Data preparation : error in machine data
CAUSE
● It was not possible to convert the MA data (files AKTUELL.MA, REAL.MA, IDEAL.MA,
RASTER.P1, RASTER.P2).
REMEDY
● Check the hard disk for bad clusters with the DOS program using the CHKDSK command; rein-
stall machine data (files) onto the hard disk.
753 Data preparation : error in cluster data
CAUSE
● It was not possible to convert the NU data.
REMEDY
● The line computer has generated a faulty cluster, check data in line computer.
754 Data preparation : error in set-up data
CAUSE
● It was not possible to convert the RU data.
REMEDY
● The line computer has generated a faulty set-up, check data in line computer.
755 Data preparation : error in package form data
CAUSE
● GF could not be converted.
REMEDY
● Check GF in the line computer.
756 Data preparation : error in fiducial data
CAUSE
● MK could not be converted.
REMEDY
● If this occurs only with a pure SIPLACE line (with MVS) it is best simply to reteach the MK.
758 LR: Error reading telegram
CAUSE
● Separators or value fields in the line computer telegram are incorrect or overrun.
REMEDY
● Check hard disk of the station (MS-DOS CHKDSK); reboot.
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
74
761 LR: No memory, task stopped
CAUSE
● Memory of the station is not fragmented.
REMEDY
● Reboot station.
762 VS: Maximal gradient number of fiducial profile exceeded
CAUSE
● Fiducial structure with poor contrast value as background; horizontal / vertical fiducial profile
which contains more than 100 gradients which reach 20% of maximum gradients.
REMEDY
● Reduce template field, select another fiducial structure.
763 BO: Error dur. memory request f. text pool (no./length)
CAUSE
● System error, not enough memory available.
REMEDY
● Inform Siemens Service
764 BO: Cannot open text file
CAUSE
● Text file not found.
REMEDY
● The name of the text file is in the file C:\Texte\SITXT.CFG. If this file does not exist, the software
must be reinstalled.
765 BO: Text index too large (text index/max index)
CAUSE
● A text in the text file is too large.
REMEDY
● Ignore but inform Siemens Service.
766 BO: Text index defined twice (text index/i. )
CAUSE
● On loading texts, double text indices were detected. Loading is repeated.
REMEDY
● Ignore, but inform Siemens Service.
767 PCB barcode: incorrect format
CAUSE
● The machine has not identified the board barcode received from the barcode reader.
REMEDY
● Input manually via the keyboard or try again. Once placement of the current board is complete the
error menu will drop down.