Error Messages Short Reference SIPLACE 80 S-15/F3/G 03/99 Issue Software Version SR.010.x x 68 715 BO: Error in pause (sts) CAUSE ● System error during syst em call P AUSE. REMEDY ● When the machine is a t a standstill, …
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
67
708 CRDL 2 configured without mechanical centering
CAUSE
● Despite the CRDL tester, the mechanical centering station has not been configured (tester wit-
hout mechanical centering station is not possible)
REMEDY
● Correct the configuration in the line computer for this station.
709 BO: Event flag ID unknown (flag id)
CAUSE
● System error during system call SVC-Look for event flag group of the keyboard task
REMEDY
● When the machine is at a standstill, reset the machine.
710 BO: Error in RIO. HSFS_XREAD (sts)
CAUSE
● System error during keyboard input.
REMEDY
● When the machine is at a standstill, reset the machine.
711 BO: 1st state byte HSFS_XREAD (status[0])
CAUSE
● System error during keyboard input.
REMEDY
● When the machine is at a standstill, reset the machine.
712 BO: Error in RIO POLL_XBUF (sts)
CAUSE
● System error during keyboard input.
REMEDY
● When the machine is at a standstill, reset the machine.
713 BO: 1st status byte POLL_XBUF (status[0])
CAUSE
● System error during keyboard input.
REMEDY
● When the machine is at a standstill, reset the machine.
714 NF: no memory available
CAUSE
● System error
REMEDY
● Reboot
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
68
715 BO: Error in pause (sts)
CAUSE
● System error during system call PAUSE.
REMEDY
● When the machine is at a standstill, reset the machine.
716 BO Barcode terminator not found
CAUSE
● The terminator is missing after the barcode header, barcode at the barcode pen not recognized.
REMEDY
● Reread the barcode. If this does not work, check the barcode header and terminator.
717 BO: 1st character of barcode terminator not found
CAUSE
● The terminator is missing after the barcode header, barcode at the barcode pen not recognized.
REMEDY
● Reread the barcode. If this does not work, check the barcode header and terminator.
718 VS: Unknown message code
CAUSE
● Software error
REMEDY
● Inform Siemens Service; possibly reboot.
719 VS: Error during system call look
CAUSE
● Software error
REMEDY
● Inform Siemens Service; possibly reboot.
720 VS: File could not be opened
CAUSE
● File does not exist in the station computer
REMEDY
● Reinstall software
721 VS: Error in fiducial data
CAUSE
● Fiducial data erroneous; obsolete ICOS version
REMEDY
● Reset ICOS, update eproms
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
69
722 VS: Error during memory request
CAUSE
● Software error
REMEDY
● Reboot; inform Siemens Service.
723 VS: File could not be opened
CAUSE
● File does not exist in the station computer (TISCH.HEX)
REMEDY
● Reinstall software (possibly only TISCH.HEX)
724 VS: Error during memory request
CAUSE
● Not enough memory available in the station computer
REMEDY
● Reset station computer
725 VS: Error during memory release in VS load
CAUSE
● Software error
REMEDY
● Inform Siemens Service.
726 VS: Error in message reception
CAUSE
● Software error
REMEDY
● Inform Siemens Service; possibly reboot.
727 VS: Error in send function in SC
CAUSE
● Software error
REMEDY
● Inform Siemens Service; possibly reboot.
728 VS: Unknown state
CAUSE
● Software error
REMEDY
● Inform Siemens Service; possibly reboot.