00191494-01.pdf - 第82页
Error Messages Short Reference SIPLACE 80 S-15/F3/G 03/99 Issue Software Version SR.010.x x 80 804 BO: POOL cannot be given b ack (length); CAUSE ● A requested memory ar ea can no longer be return ed, system error . REME…
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
79
797 BO: Text line interrupted at type (character/i)
CAUSE
● Contents of the text file are faulty.
REMEDY
● If the error occurs again after error message 704, reset station.
798 BO: Text line interrupted at name (character/i)
CAUSE
● Contents of the text file are faulty.
REMEDY
● If the error occurs again after error message 704, reset station.
799 BO: Unknown state while loading texts (state)
CAUSE
● System error while loading the texts.
REMEDY
● Reset station.
800 BO: Text too long (text index/actual length)
CAUSE
● A text is longer than permitted.
REMEDY
● If the error occurs again after error message 704, inform Siemens Service.
801 BO: Invalid length information (text index/ith char)
CAUSE
● Contents of the text file are faulty.
REMEDY
● If the error occurs again after error message 704, reset station.
802 BO: Postponement line full (ident/code)
CAUSE
● The operator interface is receiving too many jobs and cannot process these.
REMEDY
● Reset station.
803 BO: Insufficient memory for postponement (length)
CAUSE
● No memory available.
REMEDY
● Reset station.
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
80
804 BO: POOL cannot be given back (length);
CAUSE
● A requested memory area can no longer be returned, system error.
REMEDY
● Reset station.
805 BO: Message cannot be sent (state/code)
CAUSE
● Error during system call "send" or not enough memory available.
REMEDY
● Reset station.
806 NF: unexpected input
CAUSE
● System error
REMEDY
● If possible, ignore
807 KLKONF: System error during initialization
CAUSE
● Software error in glueing configuration task
REMEDY
● Reboot
808 KLKONF: System error during memory request
CAUSE
● Software error in glueing configuration task during memory request
REMEDY
● Reboot
809 KLKONF: System error during give back memory
CAUSE
● Software error in glueing configuration task during give back of memory
REMEDY
● Reboot
810 KLKONF: System error during send message
CAUSE
● Software error in glueing configuration task during send message
REMEDY
● Reboot
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
81
811 KLKONF: Incorrect input
CAUSE
● Software error in glueing configuration task; Incorrect message received
REMEDY
● Reboot
812 KLKONF: Invalid input data
CAUSE
● Software error in glueing configuration task; Incorrect data received from data preparation
REMEDY
● Reboot; get the data organized
813 WARNING: Glue data from file ".ZKL" invalid
CAUSE
● 1. No *.ZKL can be found (with glueing parameters which have not yet been manipulated).
2. Data from "ZKL" incorrect.
REMEDY
● To 1. Not an error
To 2. Delete *.ZKL, manipulate, then a new *.ZKL will be created.
814 Glueing data cannot be modified
CAUSE
● Software error
REMEDY
● Reboot
815 DP: Incorrect operating system call
CAUSE
● Software error
REMEDY
● Siemens Service should be notified.
816 DP: No LC command in service without LC
CAUSE
● Machine in "service without line computer" but all the same command received via IEC bus.
REMEDY
● Machines and line configuration should be checked.
817 DP: Set-up without valid machine data
CAUSE
● Incorrect data supply from the line computer.
REMEDY
● Data supply from the line computer should be checked.