Error Messages Short Reference SIPLACE 80 S-15/F3/G 03/99 Issue Software Version SR.010.x x 112 1 138 Z-axis error, GU1: Reference point not found CAUSE ● Reference pulse not fo und on increment disk; incre ment disk dir…

100%1 / 124
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
111
1131 Z-axis error, GU1: incorrect acceleration
CAUSE
Invalid value in the machine data
REMEDY
Check the machine data
1132 Z-axis error; GU2: incorrect acceleration
CAUSE
Invalid value in the machine data
REMEDY
Check the machine data
1133 Z-axis error; GU3: incorrect acceleration
CAUSE
Invalid value in the machine data
REMEDY
Check the machine data
1134 X-axis error: Reference point not found
CAUSE
Reference point not found on scale; scale dirty or defective
REMEDY
Check scale; repeat reference run
1135 Y-axis error: Reference point not found
CAUSE
Reference point not found on scale; scale dirty or defective
REMEDY
Check scale; repeat reference run
1136 xk-axis error: Reference point not found
CAUSE
Reference pulse not found on increment disk; increment disk dirty or defective
REMEDY
Repeat reference run; check incremental pulses; if necessary, replace motor unit
1137 yk-axis error: Reference point not found
CAUSE
Reference pulse not found on increment disk; increment disk dirty or defective
REMEDY
Repeat reference run; check incremental pulses; if necessary, replace motor unit
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
112
1138 Z-axis error, GU1: Reference point not found
CAUSE
Reference pulse not found on increment disk; increment disk dirty or defective
REMEDY
Repeat reference run; check incremental pulses; if necessary, replace motor unit
1139 Z-axis error; GU2: Reference point not found
CAUSE
Reference pulse not found on increment disk; increment disk dirty or defective
REMEDY
Repeat reference run; check incremental pulses; if necessary, replace motor unit
1140 Z-axis error; GU3: Reference point not found
CAUSE
Reference pulse not found on increment disk; increment disk dirty or defective
REMEDY
Repeat reference run; check incremental pulses; if necessary, replace motor unit
1141 X-axis error: I-square
CAUSE
R.m.s. current of the servo-amplifier exceeded; motor overloaded; mechanically stiff-running
REMEDY
Motor current should be checked; carry out maintenance on mechanism
1142 Y-axis error: I-square
CAUSE
R.m.s. current of the servo-amplifier exceeded; motor overloaded; mechanically stiff-running
REMEDY
Motor current should be checked; carry out maintenance on mechanism
1143 xk-axis error: I-square
CAUSE
R.m.s. current of the servo-amplifier exceeded; motor overloaded; mechanically stiff-running
REMEDY
Motor current should be checked; carry out maintenance on mechanism
1144 yk-axis error: I-square
CAUSE
R.m.s. current of the servo-amplifier exceeded; motor overloaded; mechanically stiff-running
REMEDY
Motor current should be checked; carry out maintenance on mechanism
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
113
1145 Z-axis error, GU1: I-square
CAUSE
R.m.s. current of the servo-amplifier exceeded; motor overloaded; mechanically stiff-running
REMEDY
Motor current should be checked; carry out maintenance on mechanism
1146 Z-axis error; GU2: I-square
CAUSE
R.m.s. current of the servo-amplifier exceeded; motor overloaded; mechanically stiff-running
REMEDY
Motor current should be checked; carry out maintenance on mechanism
1147 Z-axis error; GU3: I-square
CAUSE
R.m.s. current of the servo-amplifier exceeded; motor overloaded; mechanically stiff-running
REMEDY
Motor current should be checked; carry out maintenance on mechanism
1148 GU does not execute command
CAUSE
When transmitting to the glueing unit it does not send an acknowledgement; V24 connection
interrupted; control board GU defective
REMEDY
V24 connection should be checked; control board GU should be repaired
1149 GU does not send data
CAUSE
When data is requested from the GU, it does not send any data
REMEDY
Hardware of MC-GU should be checked; V24 connection should be checked; carry out mainte-
nance on control board GU
1150 GU: Receiving buffer too small
CAUSE
Record length when sending or receiving to or from the GU exceeds the sending / receiving buffer
Software error - incompatible versions of MC and GU
REMEDY
Check versions
1151 GU: Checksum error
CAUSE
When sending to the GU a negative acknowledgement is received from the GU
REMEDY
Software error. Siemens Service should be notified