00191494-01.pdf - 第66页

Error Messages Short Reference SIPLACE 80 S-15/F3/G 03/99 Issue Software Version SR.010.x x 64 574 Feeder position recognition n ot possible CAUSE ● Conveyor fiducials are o utside the travel range of t he main axes REME…

100%1 / 124
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
63
567 Error while loading coplanarity data into module
CAUSE
Coplanarity has been selected for BGAs; erroneous GF description in the line computer
REMEDY
Deactivate coplanarity option; check GF description
568 Error while loading parameter pool into MVS
CAUSE
Erroneous data in the SST.ma file; incorrect MVS Eprom version
REMEDY
Check the SST.ma file; check the MVS Eprom version
569 Limited feeder position recognition
CAUSE
Feeder fiducials are outside the travel range of the main axes
REMEDY
Set feeder up for locations which lie within the travel range of the board camera
570 Nozzle not picked up from <magazine/garage>:
CAUSE
Garage indicated of the magazine in question is already empty; x, y or z positions are not correct
(real.ma)
REMEDY
Set magazine full; check the garage in question
571 Nozzle not returned to <magazine/garage>:
CAUSE
Garage indicated of the magazine in question is already occupied; x, y or z positions are not cor-
rect (real.ma)
REMEDY
Nozzle is discarded into rejects tray; check the garage in question
572 Nozzle type not available <type/for segment>:
CAUSE
Nozzle type displayed has not been set up or the corresponding magazine is empty
REMEDY
Fill magazine or insert by hand and confirm in the menu
573 Nozzle type not returnable <type/from segment>:
CAUSE
Magazine displayed has not been set up for this nozzle type or the magazine is full
REMEDY
Nozzle is discarded into the rejects tray
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
64
574 Feeder position recognition not possible
CAUSE
Conveyor fiducials are outside the travel range of the main axes
REMEDY
Set up the conveyor for locations which are within the travel range of the board camera
575 Incorrect centering device setting for component concerned
CAUSE
Incorrect entry in the line computer GF editor.
REMEDY
Change the processing data for the package form in the line computer GF editor.
576 Incorrect placement sequence in cluster data
CAUSE
Inconsistency in the cluster data
TO RECTIFY
Generate a new placement sequence on the line computer. Notify Siemens Service.
578 Nozzle not ejected into rejects box
CAUSE
The component or the nozzle is jamming at the rejects box.
The rejects box is full.
REMEDY
Use the SITEST program to record the x, y and z nozzle positions.
Remove the obstacle or empty the rejects box.
579 Coplan: Bad component, to be returned
CAUSE
Lead height outside tolerance.
TO RECTIFY
Discard the component.
580 Copl: Comp. cannot be measured (ex. offset)
CAUSE
Coplanarity measurement not possible due to results of optical centering measurement.
TO RECTIFY
Discard the component.
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
65
694 Incorrect nozzle length
CAUSE
No nozzle present.
The nozzle is seated incorrectly.
The wrong nozzle type has been set up.
REMEDY
Make sure the head is fitted with the correct nozzle.
Check the seating of the nozzle.
696 Warning: Break to DP1-axis
CAUSE
Internal program run error when the DP1-axis is overshooting.
REMEDY
Confirm the error message.
If this error occurs frequently, please notify Siemens Service
697 Warning: Break to DP2-axis
CAUSE
Internal program run error when the DP1-axis is overshooting.
REMEDY
Confirm the error message.
If this error occurs frequently, please notify Siemens Service
698 Error during break to DP1-axis: boot!
CAUSE
It is not possible to confirm error message 696 with respect to the internal program run error.
REMEDY
Reboot the station. Notify Siemens Service.
699 Error during break to DP2-axis: boot!
CAUSE
It is not possible to confirm error message 697 with respect to the internal program run error.
REMEDY
Reboot the station. Notify Siemens Service.
701 BO: Info received is not a message (ident/code)
CAUSE
BO has received a message which is not actually classified as a message. The details (ident
code) concern the contents of the message. These values are given in (Info1/Info2).
REMEDY
Write down error message giving the complete error message and under what conditions the
error occurred. With the machine at standstill, reset the machine.