Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
94
902 OPT: No memory received
CAUSE
Software error in glue optimization: no more memory available
REMEDY
Files may be too large; reboot
903 OPT: Error during look
CAUSE
Software error in glue optimization
REMEDY
Reboot
904 OPT: No glueing position received
CAUSE
Glue optimization received the glueing number "zero"
REMEDY
Check data
905 Glueing size not possible with glue available
CAUSE
Glueing size specified by the line computer in this cluster is not possible with the glue set up
REMEDY
Set up glue again
906 OPT: Glueing size received is invalid
CAUSE
Glueing size is larger than 20
REMEDY
Check data
907 OPT: Glueing position outside of travel range
CAUSE
Optimization received a position outside the travel range
REMEDY
Travel range and cluster should be checked
908 Caution: PCB transported through by line computer
CAUSE
Board barcode has been sent to line computer; the line computer does not have this barcode in
its list
REMEDY
Wrong board fed in; something wrong with the list in the line computer.
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
95
909 DP: Glue type list KLL incorrectly loaded
CAUSE
Faulty data (*.vkl, SIPLACE.KLL) on the hard disk
REMEDY
Check all *.vkl files (including file name in the file)
910 VS: Search for array index not successful
CAUSE
The job file is not consistent
REMEDY
Check the camera records in REAL.MA; check the job data (GF data) in the line computer.
911 OPT: Spacer in contact with glueing point
CAUSE
Glueing points are too close together or their position relative to the spacer is not good.
REMEDY
Reposition the spacer and reoptimize the cluster.
NOTE
The spacer angle must be input in the "Modify system data" menu.
912 DP: axis type incorrect in small gantry mapping data
CAUSE
Incorrect axis type in the RASTER.K1 file (mapping data for glueing station for small gantries)
REMEDY
Make the necessary correction in the machine file RASTER.K1 (axis type).
913 DP: Gantry ID error in small gantry mapping data
CAUSE
Incorrect gantry identification in RASTER.K1 file (mapping data for glueing station for small gan-
tries)
REMEDY
Make the necessary correction in the machine file RASTER.K1 (axis type).
1005 Z-axis; GU1: Bero at top does not react
CAUSE
Z1-axis is not positioned high enough; Bero defective; Z1-axis is jamming
motor, controller, servo-amplifier defective.
REMEDY
Check the components just mentioned.
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
96
1006 Z-axis; GU2: Bero at top does not react
CAUSE
Z2-axis is not positioned high enough; Bero defective; Z2-axis is jamming
motor, controller, servo-amplifier defective.
REMEDY
Check the components just mentioned.
1007 Z-axis; GU3: Bero at top does not react
CAUSE
Z3-axis is not positioned high enough; Bero defective; Z3-axis is jamming
motor, controller, servo-amplifier defective.
REMEDY
Check the components just mentioned.
1010 Z-axis; GU1: cannot be moved any further upwards
CAUSE
When the start button is pressed the Z1-axis is below the minimum position
REMEDY
The servo-amplifier should be checked; slide the Z1-axis upwards by hand
1011 Z-axis; GU2: cannot be moved any further upwards
CAUSE
When the start button is pressed the Z2-axis is below the minimum position
REMEDY
The servo-amplifier should be checked; slide the Z2-axis upwards by hand
1012 Z-axis; GU3: cannot be moved any further upwards
CAUSE
When the start button is pressed the Z3-axis is below the minimum position
REMEDY
The servo-amplifier should be checked; slide the Z3-axis upwards by hand
1018 xk-axis: Target position not reached
CAUSE
Machine data not correct; mechanism is jamming;
drive motor, tachometer, incremental encoder, servo-amplifier defective; calibration of the axis
incorrect.
REMEDY
Check machine data; check the mechanism; check the axis calibration
or check the components; if necessary, replace