Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
16
157 Both limit switches of width adjustment actuated
CAUSE
● Limit switch of the conveyor belt width adjustment is defective
REMEDY
● Check the limit switches
158 Limit switch of width adjustment for minimum width actuated
CAUSE
● Conveyor belt width has been set too small
REMEDY
● Increase conveyor belt width
159 Limit switch of width adjustment for maximum width actuated
CAUSE
● Conveyor belt width has been set too large
REMEDY
● Reduce conveyor belt width
160 Bero not found during conveyor belt width check
CAUSE
● Conveyor belt bero is defective or set incorrectly
REMEDY
● Check bero
161 Bero covered before conveyor belt width check
CAUSE
● Conveyor belt bero responds before the actual position (gantry) is reached
REMEDY
● Adjust bero
162 WPC must be moved from refill position
CAUSE
● WPC is in the refill position
REMEDY
● The operator should quit the refill position in the "Refill" "Location1" menu.
163 Conveyor belt width out of travel range
CAUSE
● The conveyor width detected lies outside of the possible range of values.
The sensing distance of the bero has been set too high.
The bero is defective.
REMEDY
● Use the SITEST program to re-register the 100mm board and run width measurement again.
The sensing distance of the bero has been set too high.
Replace bero.
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
17
201 Track empty, optical centering incorrect
CAUSE
● 3 optical measuring errors with component from one track; set up for incorrect component.
Incorrect angle has been input for the component in the feeder.
REMEDY
● Check components feed; fill up empty track and reset track.
check set-up data.
202 Track empty, measure value outside tol.
CAUSE
● 3 electrical measurement errors with component from one track
REMEDY
● Check components feed; fill up empty track and reset track.
203 Track put out of operation by operator
CAUSE
● Under the menu "Refill" track set to empty.
REMEDY
● Reset track in the menu "Refill".
204 Z-axis cannot be moved upwards
CAUSE
● When the start button pressed Z-axis not in top position.
REMEDY
● Check servo, push Z-axis upwards by hand.
205 BERO for Z-axis top position not released
CAUSE
● Sensing distance too great; Bero defective; cam disk not tightened up correctly; z zero point cor-
rection value incorrect; counting error.
REMEDY
● Adjust sensing distance; replace Bero; tighten up cam disk; redetermine z zero point correction;
fit new motor/tacho/encoder; carry out axis calibration.
206 Fault in pick-up station during vac. meas.
CAUSE
● Suction face of the nozzle damaged; nozzle too small; component was not supplied.
REMEDY
● Fit new nozzle; check component feed.
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
18
207 Fault in placement stat. during vac. meas.
CAUSE
● Suction face of the nozzle damaged; nozzle too small; jaws of the centering station bouncing;
component was not picked up properly; vacuum in the holding circuit too low; vacuum board
defective.
REMEDY
● Fit new nozzle; calibration of the motor control board; check component feed, call Siemens Ser-
vice.
208 End position BERO of centering station not being actuated
CAUSE
● End position Bero defective or incorrectly set; recuperator spring of the centering station worn
out.
REMEDY
● Fit new Bero, adjust; maintain centering station.
209 Counting error X-axis
CAUSE
● Scales dirty (incremental encoder).
REMEDY
● Clean scales (incremental encoder).
210 Measurement trigger BERO of centering station not actuated
CAUSE
● Distance between Bero and actuator flag too great; Bero defective
REMEDY
● Correct distance to actuator flag; fit new Bero.
211 Counting error Y-axis
CAUSE
● Scales dirty (incremental encoder).
REMEDY
● Clean scales (incremental encoder).
212 Fault during vacuum measuring in reject position
CAUSE
● O-ring on the sealing piston damaged.
REMEDY
● Fit new O-ring to the sealing piston.
213 Timeout during reception from coplanarity
CAUSE
● Coplanarity module not plugged in
REMEDY
● Plug in module