00191494-01.pdf - 第56页

Error Messages Short Reference SIPLACE 80 S-15/F3/G 03/99 Issue Software Version SR.010.x x 54 499 Peak offset: Component outsid e of search area CAUSE ● Component was not pic ked up correctly . REMEDY ● Check component …

100%1 / 124
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
53
492 Coplanarity module defective; replace and boot
CAUSE
Internal error of the coplanarity module.
REMEDY
Inform Siemens Service.
493 Coplanarity module defective; replace and boot
CAUSE
Internal error of the coplanarity module.
REMEDY
Inform Siemens Service.
494 Coplanarity module defective; replace and boot
CAUSE
Internal error of the coplanarity module.
REMEDY
Inform Siemens Service.
495 Coplanarity module defective; replace and boot
CAUSE
Internal error of the coplanarity module.
REMEDY
Inform Siemens Service.
496 Coplanarity module defective; replace and boot
CAUSE
Internal error of the coplanarity module.
REMEDY
Inform Siemens Service.
497 Software error in coplanarity module; boot
CAUSE
Internal error of the coplanarity module.
REMEDY
Inform Siemens Service.
498 Coplan.: Command Quit sent
CAUSE
Software error
REMEDY
Inform Siemens Service.
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
54
499 Peak offset: Component outside of search area
CAUSE
Component was not picked up correctly.
REMEDY
Check component description and pick-up position.
500 Peak offset: Evaluation not possible
CAUSE
No component at the nozzle; component outside tolerance; not enough image information to pro-
vide measurement result.
REMEDY
Optimize pick-up; check charge (component).
501 Error in default branch
CAUSE
The format of the measurement results from optical centering cannot be interpreted by the MC
software.
REMEDY
Check sure that the MVS Eprom version is compatible with the station computer software.
502 MC has received wrong error number
CAUSE
Software error: the error number lies outside the error range
REMEDY
Notify Siemens Service.
503 Flatpack magazine is empty
CAUSE
Last component of a flatpack magazine has been picked up.
REMEDY
Change flatpack magazine.
504 Current limiter I
r.m.s
has reacted
CAUSE
Servo is being subjected to limitation, axis jamming.
REMEDY
Check mechanism for ease of running.
505 Error during RMOS System Call RECV
CAUSE
Software error
REMEDY
Reboot and inform Siemens Service.
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
55
506 Error during RMOS System Call DALOC
CAUSE
Software error
REMEDY
Reboot and inform Siemens Service.
507 Error during RMOS System Call ALOC
CAUSE
Software error
REMEDY
Reboot and inform Siemens Service.
508 Error during RMOS System Call LOOK
CAUSE
Software error
REMEDY
Reboot and inform Siemens Service.
509 Error during RMOS System Call RIO
CAUSE
Software error
REMEDY
Reboot and inform Siemens Service.
510 Error during RMOS System Call CREATEDRIV
CAUSE
Software error
REMEDY
Reboot and inform Siemens Service.
511 Error during RMOS System Call MALLOC
CAUSE
Software error
REMEDY
Reboot and inform Siemens Service.
512 Incorrect value of state counter
CAUSE
Software error
REMEDY
Reboot