00191494-01.pdf - 第9页
Short Reference SIPLACE 80 S-15/F3/G Error Messages 03/99 Issue Software Version SR.010.x x 7 52 BERO SZ2 not being actuated CAUSE ● Bad plugged connection of the screwdriver at the gantr y board; motor control board def…
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
6
30 BERO SZ2 not released (close segment)
CAUSE
● Proximity switch defective; component jammed between screwdriver and segment;
motor of the screwdriver defective.
REMEDY
● Replace proximity switch, adjust sensing distance; remove component; check toothing for
damage; replace motor with hub, carry out calibration on the motor control board.
38 Star axis does not reach setpoint position ?
CAUSE
● Segment slit position incorrect at insertion; component jammed between toothed belt and toothed
belt pulley; speed was input incorrectly in the MA_DATA; power supply interrupted; motor defec-
tive; belt tension not correct; segment cam is rubbing against the Z-axis.
REMEDY
● Insert segment with correct slit position; remove component; correct speed value correspondin-
gly; check plugged connections; replace motor, adjust toothed belt tension, carry out calibration of
the servo board; slacken cam leaf springs of segment and realign cam.
43 Component not at nozzle after pick-up
CAUSE
● Suction face of the nozzle damaged; nozzle too small; component was not supplied.
REMEDY
● Fit new nozzle; check component feed.
44 Component not at nozzle before placement
CAUSE
● Suction face of the nozzle damaged; nozzle too small; jaws of the centering station bouncing;
component was not picked up properly; vacuum in the holding circuit too low; vacuum board
defective.
REMEDY
● Fit new nozzle; carry out calibration of the motor control board; check component feed, call Sie-
mens Service.
48 Results of vac measurement of pick-up & reject station inversed
CAUSE
● Vacuum circuit defective; compressed air bad.
REMEDY
● Check vacuum circuit; check compressed air.
50 SZ1 only succeeded on the second attempt
CAUSE
● Stiffness in the gearwheel/pinion of the screwdriver; stiffness in the pusher movement; calibration
of the motor control board not optimal.
REMEDY
● Maintain screwdriver; maintain segment; carry out calibration of the motor control board.
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
7
52 BERO SZ2 not being actuated
CAUSE
● Bad plugged connection of the screwdriver at the gantry board; motor control board
defective.
REMEDY
● Check plugged connections; fit new motor control board, carry out calibration of the axes.
53 SZ2 only succeeded on second attempt
CAUSE
● Stiffness in the gearwheel/pinion of the screwdriver; stiffness in the pusher movement; calibration
of the motor control board not optimal.
REMEDY
● Maintain screwdriver; maintain segment; carry out calibration of the motor control board.
54 BERO SZ1 not being actuated
CAUSE
● Bad plugged connection of the screwdriver at the gantry board; motor control board defective.
REMEDY
● Check plugged connections; fit new motor control board, carry out calibration of the axes.
59 X-axis does not reach setpoint position
CAUSE
● Mechanism jamming; toothed belt parted; drive motor with tacho defective; calibration of the axis
incorrect.
REMEDY
● Check mechanism; fit new toothed belt; fit new motor with tacho; carry out axis calibration.
60 Y-axis does not reach setpoint position
CAUSE
● Mechanism jamming; toothed belt parted; drive motor with tacho defective; calibration of the axis
incorrect.
REMEDY
● Check mechanism; fit new toothed belt; fit new motor with tacho; carry out axis calibration.
61 Z-axis does not reach setpoint position
CAUSE
● Cam disk in incorrect position at zero pulse; motor defective; Z-axis jamming.
REMEDY
● Fit cam disk in correct rotational position; redetermine zero point correction; replace motor; carry
out axis calibration; fit spare placement head.
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
8
63 X-axis disabled
CAUSE
● X-axis switched off at the axis controller switch.
REMEDY
● X-axis should be switched on at the axis controller switch.
64 Y-axis disabled
CAUSE
● Y-axis switched off at the axis controller switch.
REMEDY
● Y-axis should be switched on at the axis controller switch.
65 D1-axis disabled
CAUSE
● DP1-axis switched off at the axis controller switch.
REMEDY
● DP1-axis should be switched on at the axis controller switch.
66 D2-axis disabled
CAUSE
● DP2-axis switched off at the axis controller switch.
REMEDY
● DP2-axis should be switched on at the axis controller switch.
67 Star axis disabled
CAUSE
● Star axis switched off at the axis controller switch.
REMEDY
● Star axis should be switched on at the axis controller switch.
68 Z-axis disabled
CAUSE
● Z-axis switched off at the axis controller switch.
REMEDY
● Z-axis should be switched on at the axis controller switch.
75 Programmed position of Z-axis outside travel range
CAUSE
● Machine data in the line computer erroneous; height reference run is not carried out on the PCB
conveyor.
REMEDY
● Check the machine data in the line computer.