00191494-01.pdf - 第9页

Short Reference SIPLACE 80 S-15/F3/G Error Messages 03/99 Issue Software Version SR.010.x x 7 52 BERO SZ2 not being actuated CAUSE ● Bad plugged connection of the screwdriver at the gantr y board; motor control board def…

100%1 / 124
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
6
30 BERO SZ2 not released (close segment)
CAUSE
Proximity switch defective; component jammed between screwdriver and segment;
motor of the screwdriver defective.
REMEDY
Replace proximity switch, adjust sensing distance; remove component; check toothing for
damage; replace motor with hub, carry out calibration on the motor control board.
38 Star axis does not reach setpoint position ?
CAUSE
Segment slit position incorrect at insertion; component jammed between toothed belt and toothed
belt pulley; speed was input incorrectly in the MA_DATA; power supply interrupted; motor defec-
tive; belt tension not correct; segment cam is rubbing against the Z-axis.
REMEDY
Insert segment with correct slit position; remove component; correct speed value correspondin-
gly; check plugged connections; replace motor, adjust toothed belt tension, carry out calibration of
the servo board; slacken cam leaf springs of segment and realign cam.
43 Component not at nozzle after pick-up
CAUSE
Suction face of the nozzle damaged; nozzle too small; component was not supplied.
REMEDY
Fit new nozzle; check component feed.
44 Component not at nozzle before placement
CAUSE
Suction face of the nozzle damaged; nozzle too small; jaws of the centering station bouncing;
component was not picked up properly; vacuum in the holding circuit too low; vacuum board
defective.
REMEDY
Fit new nozzle; carry out calibration of the motor control board; check component feed, call Sie-
mens Service.
48 Results of vac measurement of pick-up & reject station inversed
CAUSE
Vacuum circuit defective; compressed air bad.
REMEDY
Check vacuum circuit; check compressed air.
50 SZ1 only succeeded on the second attempt
CAUSE
Stiffness in the gearwheel/pinion of the screwdriver; stiffness in the pusher movement; calibration
of the motor control board not optimal.
REMEDY
Maintain screwdriver; maintain segment; carry out calibration of the motor control board.
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
7
52 BERO SZ2 not being actuated
CAUSE
Bad plugged connection of the screwdriver at the gantry board; motor control board
defective.
REMEDY
Check plugged connections; fit new motor control board, carry out calibration of the axes.
53 SZ2 only succeeded on second attempt
CAUSE
Stiffness in the gearwheel/pinion of the screwdriver; stiffness in the pusher movement; calibration
of the motor control board not optimal.
REMEDY
Maintain screwdriver; maintain segment; carry out calibration of the motor control board.
54 BERO SZ1 not being actuated
CAUSE
Bad plugged connection of the screwdriver at the gantry board; motor control board defective.
REMEDY
Check plugged connections; fit new motor control board, carry out calibration of the axes.
59 X-axis does not reach setpoint position
CAUSE
Mechanism jamming; toothed belt parted; drive motor with tacho defective; calibration of the axis
incorrect.
REMEDY
Check mechanism; fit new toothed belt; fit new motor with tacho; carry out axis calibration.
60 Y-axis does not reach setpoint position
CAUSE
Mechanism jamming; toothed belt parted; drive motor with tacho defective; calibration of the axis
incorrect.
REMEDY
Check mechanism; fit new toothed belt; fit new motor with tacho; carry out axis calibration.
61 Z-axis does not reach setpoint position
CAUSE
Cam disk in incorrect position at zero pulse; motor defective; Z-axis jamming.
REMEDY
Fit cam disk in correct rotational position; redetermine zero point correction; replace motor; carry
out axis calibration; fit spare placement head.
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
8
63 X-axis disabled
CAUSE
X-axis switched off at the axis controller switch.
REMEDY
X-axis should be switched on at the axis controller switch.
64 Y-axis disabled
CAUSE
Y-axis switched off at the axis controller switch.
REMEDY
Y-axis should be switched on at the axis controller switch.
65 D1-axis disabled
CAUSE
DP1-axis switched off at the axis controller switch.
REMEDY
DP1-axis should be switched on at the axis controller switch.
66 D2-axis disabled
CAUSE
DP2-axis switched off at the axis controller switch.
REMEDY
DP2-axis should be switched on at the axis controller switch.
67 Star axis disabled
CAUSE
Star axis switched off at the axis controller switch.
REMEDY
Star axis should be switched on at the axis controller switch.
68 Z-axis disabled
CAUSE
Z-axis switched off at the axis controller switch.
REMEDY
Z-axis should be switched on at the axis controller switch.
75 Programmed position of Z-axis outside travel range
CAUSE
Machine data in the line computer erroneous; height reference run is not carried out on the PCB
conveyor.
REMEDY
Check the machine data in the line computer.