Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
41
384 BERO SZ1 not released
CAUSE
Proximity switch defective; component jammed between screwdriver and segment;
motor of the screwdriver defective.
REMEDY
Replace proximity switch, adjust sensing distance; remove component; check toothing for
damage; replace motor with hub, carry out calibration on the motor control board.
385 BERO SZ2 not released
CAUSE
Proximity switch defective; component jammed between screwdriver and segment;
motor of the screwdriver defective.
REMEDY
Replace proximity switch, adjust sensing distance; remove component; check toothing for
damage; replace motor with hub, carry out calibration on the motor control board.
386 Input conveyor occupied
CAUSE
When the belt speed was set there was a PCB board on the input conveyor; sensor defective
REMEDY
Remove the PCB board; fit new sensor.
387 VS: No reaction from M10000 (reset M10000)
CAUSE
M10000 crash; line interruption
REMEDY
Reset M10000; check cable connection.
388 Check sum error in table program
CAUSE
File TISCH.HEX erroneous.
REMEDY
Replace file TISCH.HEX in the station computer.
389 Coplan.: Component will not be processed
CAUSE
Measurement of a component for which no prepare command was sent to the coplanarity module
(error in the cluster and set-up)
REMEDY
Respecify cluster and set-up.
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
42
390 Coplan.: Component not loaded
CAUSE
Attempt to measure a component for which no component description was sent to the coplanarity
module.
REMEDY
Check and respecify cluster, set-up and package form data.
391 Coplan.: Row number invalid
CAUSE
Package form description erroneous; software error.
REMEDY
Check and respecify package form description; inform Siemens Service.
392 Coplan.: Row number will not be processed
CAUSE
Package form description erroneous; software error.
REMEDY
Check and respecify package form description; inform Siemens Service.
393 Number of pins on component not correct
CAUSE
Bent / missing pins; erroneous package form description
REMEDY
Check components charge check; check package form description in the package form editor.
394 Orthogonality error during component meas.
CAUSE
Incorrect or deformed component.
REMEDY
Check components charge check.
395 Dualport RAM of CRDL defective
CAUSE
Hardware error in the tester.
REMEDY
If electrical measuring is not possible, reset station; if resetting does not work, replace tester.
396 Check sum error in CRDL measurement
CAUSE
Transmission error during transmission of machine controller with tester.
REMEDY
If electrical measuring is not possible, reset station; if resetting does not work, replace tester.
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
43
397 Check sum error in communication with table
CAUSE
Transmission error during transmission of machine controller with component table.
REMEDY
If error keeps recurring, reset station; if resetting does not work, replace component table.
398 Coplan.: Row not available
CAUSE
Package form description erroneous; software error.
REMEDY
Check and respecify package form description; inform Siemens Service.
399 Program loss of table or trolley control
CAUSE
Battery reserve in the component table is not working.
REMEDY
Fit new battery to component table.
400 RAM of trolley control defective
CAUSE
Hardware error in the component table
REMEDY
If error keeps recurring, reset station; if resetting does not work, replace component table.
401 New nozzle configuration is required
CAUSE
New cluster with different nozzle configuration
REMEDY
If no nozzle changer is present, apply new nozzle configuration manually to placement head.
402 Pulse is not okay
CAUSE
Connection of pulse output to pulse input defective.
REMEDY
Check pulse output and pulse input
403 Coplan.: Too many pins measured
CAUSE
Measurement erroneous or incorrect component.
REMEDY
Repeat measurement.