Error Messages Short Reference SIPLACE 80 S-15/F3/G 03/99 Issue Software Version SR.010.x x 42 390 Coplan.: Component not loaded CAUSE ● Attempt to measure a component for which no compone nt description was sent to the …
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
41
384 BERO SZ1 not released
CAUSE
● Proximity switch defective; component jammed between screwdriver and segment;
motor of the screwdriver defective.
REMEDY
● Replace proximity switch, adjust sensing distance; remove component; check toothing for
damage; replace motor with hub, carry out calibration on the motor control board.
385 BERO SZ2 not released
CAUSE
Proximity switch defective; component jammed between screwdriver and segment;
motor of the screwdriver defective.
REMEDY
● Replace proximity switch, adjust sensing distance; remove component; check toothing for
damage; replace motor with hub, carry out calibration on the motor control board.
386 Input conveyor occupied
CAUSE
● When the belt speed was set there was a PCB board on the input conveyor; sensor defective
REMEDY
● Remove the PCB board; fit new sensor.
387 VS: No reaction from M10000 (reset M10000)
CAUSE
● M10000 crash; line interruption
REMEDY
● Reset M10000; check cable connection.
388 Check sum error in table program
CAUSE
● File TISCH.HEX erroneous.
REMEDY
● Replace file TISCH.HEX in the station computer.
389 Coplan.: Component will not be processed
CAUSE
● Measurement of a component for which no prepare command was sent to the coplanarity module
(error in the cluster and set-up)
REMEDY
● Respecify cluster and set-up.
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
42
390 Coplan.: Component not loaded
CAUSE
● Attempt to measure a component for which no component description was sent to the coplanarity
module.
REMEDY
● Check and respecify cluster, set-up and package form data.
391 Coplan.: Row number invalid
CAUSE
● Package form description erroneous; software error.
REMEDY
● Check and respecify package form description; inform Siemens Service.
392 Coplan.: Row number will not be processed
CAUSE
● Package form description erroneous; software error.
REMEDY
● Check and respecify package form description; inform Siemens Service.
393 Number of pins on component not correct
CAUSE
● Bent / missing pins; erroneous package form description
REMEDY
● Check components charge check; check package form description in the package form editor.
394 Orthogonality error during component meas.
CAUSE
● Incorrect or deformed component.
REMEDY
● Check components charge check.
395 Dualport RAM of CRDL defective
CAUSE
● Hardware error in the tester.
REMEDY
● If electrical measuring is not possible, reset station; if resetting does not work, replace tester.
396 Check sum error in CRDL measurement
CAUSE
● Transmission error during transmission of machine controller with tester.
REMEDY
● If electrical measuring is not possible, reset station; if resetting does not work, replace tester.
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
43
397 Check sum error in communication with table
CAUSE
● Transmission error during transmission of machine controller with component table.
REMEDY
● If error keeps recurring, reset station; if resetting does not work, replace component table.
398 Coplan.: Row not available
CAUSE
● Package form description erroneous; software error.
REMEDY
● Check and respecify package form description; inform Siemens Service.
399 Program loss of table or trolley control
CAUSE
● Battery reserve in the component table is not working.
REMEDY
● Fit new battery to component table.
400 RAM of trolley control defective
CAUSE
● Hardware error in the component table
REMEDY
● If error keeps recurring, reset station; if resetting does not work, replace component table.
401 New nozzle configuration is required
CAUSE
● New cluster with different nozzle configuration
REMEDY
● If no nozzle changer is present, apply new nozzle configuration manually to placement head.
402 Pulse is not okay
CAUSE
● Connection of pulse output to pulse input defective.
REMEDY
● Check pulse output and pulse input
403 Coplan.: Too many pins measured
CAUSE
● Measurement erroneous or incorrect component.
REMEDY
● Repeat measurement.