Short Reference SIPLACE 80 S-15/F3/G Error Messages 03/99 Issue Software Version SR.010.x x 75 768 No data received from PCB barcod e reader CAUSE ● PCB barcode reader not resp onding. REMEDY ● Check PCB barcode reader. …
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
74
761 LR: No memory, task stopped
CAUSE
● Memory of the station is not fragmented.
REMEDY
● Reboot station.
762 VS: Maximal gradient number of fiducial profile exceeded
CAUSE
● Fiducial structure with poor contrast value as background; horizontal / vertical fiducial profile
which contains more than 100 gradients which reach 20% of maximum gradients.
REMEDY
● Reduce template field, select another fiducial structure.
763 BO: Error dur. memory request f. text pool (no./length)
CAUSE
● System error, not enough memory available.
REMEDY
● Inform Siemens Service
764 BO: Cannot open text file
CAUSE
● Text file not found.
REMEDY
● The name of the text file is in the file C:\Texte\SITXT.CFG. If this file does not exist, the software
must be reinstalled.
765 BO: Text index too large (text index/max index)
CAUSE
● A text in the text file is too large.
REMEDY
● Ignore but inform Siemens Service.
766 BO: Text index defined twice (text index/i. )
CAUSE
● On loading texts, double text indices were detected. Loading is repeated.
REMEDY
● Ignore, but inform Siemens Service.
767 PCB barcode: incorrect format
CAUSE
● The machine has not identified the board barcode received from the barcode reader.
REMEDY
● Input manually via the keyboard or try again. Once placement of the current board is complete the
error menu will drop down.
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
75
768 No data received from PCB barcode reader
CAUSE
● PCB barcode reader not responding.
REMEDY
● Check PCB barcode reader.
769 Barcode too long, cut off!
CAUSE
● The maximum permissible length of the board barcode is 25 characters, of the component 20
characters; a longer barcode was received, but was cut short.
REMEDY
● The machine carries on working with the shortened barcode.
770 BL: unexpected input
CAUSE
● System error
REMEDY
● If possible, ignore.
771 VS: Communication between SR and MC defective
CAUSE
● Software error
REMEDY
● Reboot, if occurs repeatedly inform Siemens Service.
772 EH: received CODE unknown
CAUSE
● Incorrect message to task EH.
REMEDY
● If possible, ignore.
773 EH: received IDENT unknown
CAUSE
● Incorrect message to task EH.
REMEDY
● If possible, ignore.
774 EH: MC sending too many error messages (> F_FM_MAX)
CAUSE
● Error handling can receive a maximum of 200 error messages at the same time from the machine
controller.
REMEDY
● The error messages > 200 are discarded.
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
76
776 AKT: Error during system call ALOC
CAUSE
● No memory allocated to Task T_AKT.
REMEDY
● Reboot.
777 AKT: Incorrect input
CAUSE
● Task AKT has received unknown message.
REMEDY
● If possible, ignore, otherwise reboot.
778 AKT: Wrong data from data preparation
CAUSE
● Data preparation sending incorrect "AKTUELL.MA" format to task T_AKT.
REMEDY
● System error, reboot.
779 LRR: Undefined operation with and without LC
CAUSE
● The station computer receives a message from the line computer, but it was input at station com-
puter as "without LC".
REMEDY
● Input mode "with LC" at the station computer.
780 LRR: Undefined error in LC reception
CAUSE
● Error when receiving via IEC bus.
REMEDY
● Reboot.
781 LRR: No memory available
CAUSE
● Memory in station computer is fragmented.
REMEDY
● Reboot.
782 LRR: Defective or incomplete telegram from LC
CAUSE
● Unknown telegram from the line computer (may be incomplete)
REMEDY
● Respecify placement program in the line computer.