00191494-01.pdf - 第117页
Short Reference SIPLACE 80 S-15/F3/G Error Messages 03/99 Issue Software Version SR.010.x x 115 1 159 GU: incorrect record number during Receive CAUSE ● When receiving process data from the GU the record sum was not corr…
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
114
1152 GU: Checksum error in message from head
CAUSE
● When receiving a message from the GU the checksum is not correct.
REMEDY
● Software error of the GU. Siemens Service should be notified
1153 GU does not know command
CAUSE
● The MC sends a command to the GU which is not defined
REMEDY
● Incompatible versions of MC and GU
1154 GU is indicating error during glueing
CAUSE
● Head not initialized: no pressure build-up; no venting; no pressure.
REMEDY
● Check hoses, valves; inspect for leaks
1155 GU does not know pressure range
CAUSE
● The pressure specified in the data command is inconsistent with the head file ( .ini),
*.vkl and *.ini file are not consistent. Software error
REMEDY
● Check vkl and ini files
1156 RAM error in GU
CAUSE
● During initialization of the GU the internal RAM memory is checked. If there is a fault this will be
reported at the first glueing action
REMEDY
● Hardware GU should be checked/replaced
1157 GU: incorrect glueing command
CAUSE
● The MC has sent a command to the GU which is not defined
REMEDY
● MC/GU commands should be checked
1158 GU: incorrect record number during Send
CAUSE
● When *.ini or process data were sent from MC to GU the record number was not correct
Software error or corrupt .ini or process data files.
REMEDY
● .ini and process data files should be checked.
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
115
1159 GU: incorrect record number during Receive
CAUSE
● When receiving process data from the GU the record sum was not correct. Software error in the
GU
REMEDY
● Siemens Service should be notified
1160 GU: incorrect number of records
CAUSE
● When receiving process data from the GU the record sum was not correct. Software error in the
GU
REMEDY
● Siemens Service should be notified
1161 GU: Error during Reserve
CAUSE
● While reserving the interface for the GU an error occurred. Software error
REMEDY
● Siemens Service should be notified
1162 GU: Error during Release
CAUSE
● While releasing the interface for the GU an error occurred. Software error
REMEDY
● Siemens Service should be notified
1163 GU: Glueing order to head
CAUSE
● While the glueing order was being sent to the GU an error occurred
REMEDY
● Error is specified more precisely in a further message. Take this into account during troubleshoo-
ting
1164 GU: wait until glueing is finished
CAUSE
● While waiting for the end message from the glueing unit an error occurred
REMEDY
● Error is specified more precisely in a further message. Take this into account during troubleshoo-
ting
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
116
1165 GU: Error while setting desired temperature
CAUSE
● While the desired temperature was being sent to the GU an error occurred
REMEDY
● Error is specified more precisely in a further message. Take this into account during troubleshoo-
ting
1166 GU: Error while setting glueing point volume
CAUSE
● While the glueing point volume change was being sent to the GU an error occurred
REMEDY
● Error is specified more precisely in a further message. Take this into account during troubleshoo-
ting
1167 GU: Error while setting new cartridge
CAUSE
● An error occurred while a command was being sent to the GU that a new cartridge had been
inserted.
REMEDY
● Error is specified more precisely in a further message. Take this into account during troubleshoo-
ting
1168 GU: Error while reading actual temperature
CAUSE
● While the actual temperature was being requested for the GU an error occurred
REMEDY
● Error is specified more precisely in a further message. Take this into account during troubleshoo-
ting
1169 GU: Error during Switch on continuous glueing
CAUSE
● While the continuous glueing of the GU was being switched on an error occurred
REMEDY
● Error is specified more precisely in a further message. Take this into account during troubleshoo-
ting
1170 GU: Error during Switch off continuous glueing
CAUSE
● While the continuous glueing of the GU was being switched off an error occurred
REMEDY
● Error is specified more precisely in a further message. Take this into account during troubleshoo-
ting