Short Reference SIPLACE 80 S-15/F3/G Error Messages 03/99 Issue Software Version SR.010.x x 115 1 159 GU: incorrect record number during Receive CAUSE ● When receiving process data from the GU the record sum was not corr…

100%1 / 124
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
114
1152 GU: Checksum error in message from head
CAUSE
When receiving a message from the GU the checksum is not correct.
REMEDY
Software error of the GU. Siemens Service should be notified
1153 GU does not know command
CAUSE
The MC sends a command to the GU which is not defined
REMEDY
Incompatible versions of MC and GU
1154 GU is indicating error during glueing
CAUSE
Head not initialized: no pressure build-up; no venting; no pressure.
REMEDY
Check hoses, valves; inspect for leaks
1155 GU does not know pressure range
CAUSE
The pressure specified in the data command is inconsistent with the head file ( .ini),
*.vkl and *.ini file are not consistent. Software error
REMEDY
Check vkl and ini files
1156 RAM error in GU
CAUSE
During initialization of the GU the internal RAM memory is checked. If there is a fault this will be
reported at the first glueing action
REMEDY
Hardware GU should be checked/replaced
1157 GU: incorrect glueing command
CAUSE
The MC has sent a command to the GU which is not defined
REMEDY
MC/GU commands should be checked
1158 GU: incorrect record number during Send
CAUSE
When *.ini or process data were sent from MC to GU the record number was not correct
Software error or corrupt .ini or process data files.
REMEDY
.ini and process data files should be checked.
Short Reference SIPLACE 80 S-15/F3/G Error Messages
03/99 Issue Software Version SR.010.xx
115
1159 GU: incorrect record number during Receive
CAUSE
When receiving process data from the GU the record sum was not correct. Software error in the
GU
REMEDY
Siemens Service should be notified
1160 GU: incorrect number of records
CAUSE
When receiving process data from the GU the record sum was not correct. Software error in the
GU
REMEDY
Siemens Service should be notified
1161 GU: Error during Reserve
CAUSE
While reserving the interface for the GU an error occurred. Software error
REMEDY
Siemens Service should be notified
1162 GU: Error during Release
CAUSE
While releasing the interface for the GU an error occurred. Software error
REMEDY
Siemens Service should be notified
1163 GU: Glueing order to head
CAUSE
While the glueing order was being sent to the GU an error occurred
REMEDY
Error is specified more precisely in a further message. Take this into account during troubleshoo-
ting
1164 GU: wait until glueing is finished
CAUSE
While waiting for the end message from the glueing unit an error occurred
REMEDY
Error is specified more precisely in a further message. Take this into account during troubleshoo-
ting
Error Messages Short Reference SIPLACE 80 S-15/F3/G
03/99 Issue Software Version SR.010.xx
116
1165 GU: Error while setting desired temperature
CAUSE
While the desired temperature was being sent to the GU an error occurred
REMEDY
Error is specified more precisely in a further message. Take this into account during troubleshoo-
ting
1166 GU: Error while setting glueing point volume
CAUSE
While the glueing point volume change was being sent to the GU an error occurred
REMEDY
Error is specified more precisely in a further message. Take this into account during troubleshoo-
ting
1167 GU: Error while setting new cartridge
CAUSE
An error occurred while a command was being sent to the GU that a new cartridge had been
inserted.
REMEDY
Error is specified more precisely in a further message. Take this into account during troubleshoo-
ting
1168 GU: Error while reading actual temperature
CAUSE
While the actual temperature was being requested for the GU an error occurred
REMEDY
Error is specified more precisely in a further message. Take this into account during troubleshoo-
ting
1169 GU: Error during Switch on continuous glueing
CAUSE
While the continuous glueing of the GU was being switched on an error occurred
REMEDY
Error is specified more precisely in a further message. Take this into account during troubleshoo-
ting
1170 GU: Error during Switch off continuous glueing
CAUSE
While the continuous glueing of the GU was being switched off an error occurred
REMEDY
Error is specified more precisely in a further message. Take this into account during troubleshoo-
ting