MDO3000 Programmer Manual.pdf - 第111页

Command Groups T able 2-41: T rigger Commands (cont.) Command Description TRIGger:A:BUS:B<x>:ARINC429A:DA T A: QUALi fi er This command sets the quali fi er (<, >, =, <=, >=, not =, in range, out of range…

100%1 / 1158
Command Groups
Bus, Video and RF
application modules
A table is avail
able that lists all commands enabled by each application module
(See page H-1, List of Beta Commands and Features.)
For I
2
C or SPI b
us signals, install the DPO4EMBD application module,
except for MDO3000 models, which require MDO3EMBD.
For RS-232, RS-422, RS-485, or UART bus signals, install the DPO4COMP
module, exc
ept for MDO3000 models, which require MDO3COMP.
For I
2
S, Left Justified (LJ), Right Justified (RJ), or TDM bus signals, install
the DPO4AU
DIO module, except for MDO3000 models, which require
MDO3AUDIO.
For CAN, C
AN FD, or LIN bus signals, install the DPO4AUTO or
DPO4AUTOMAX module, except for MDO3000 models, which require
MDO3AUTO.
For FlexRay bus signals, install the DPO4AUTOMAX module, except for
MDO3000 models, which require MDO3FLEX.
For Ethernet signals, when tested with the MDO4000/B/C and
MSO/DPO4000B, install the DPO4ENET module. Note that ≥350 MHz
bandwidth models are recommended for 100BASE-TX.
For MIL-STD-1553 or ARINC429 bus signals, install the DPO4AERO
module, except for MDO3000 models, which require MDO3AERO.
For USB bus signals, install the DPO4USB module, except for
MDO3000 models, which require MDO3USB. Note that 1 GHz bandwidth
models are recommended for high-speed (HS) USB.
For video signals, install the DPO4VID module, except for the
MDO3000 models, which do not require a module.
For RF signals (MDO4000/B/C Series only), install the MDO4TRIG module.
Table 2-41: Trigger Commands
C
ommand
Description
TRIGger
Forces a trigger event to occur
TRIGger:A Sets A trigger level to 50% or returns current A trigger parameters
TRIGger:A:BANDW idth:RF :HIGH? Returns the high end of the power level trigger bandwidth range as an NR3
valueinhertz.
TRIGger:A:BANDW idth:RF :LOW ? Returns the low end of the power level trigger bandwidth range as an NR3
valueinhertz.
TRIGger:A:BUS This command species the bus type to trigger on.
TRIGger:A:BUS:B<x>:ARINC429A:CONDition This command sets the condition to use when triggering on a ARINC429 bus
signal (word start, label, matching data, word end, or error).
TRIGger:A:BUS:B<x>:ARINC429A:DATA:HIVALue This command species the high value to use when triggering on a ARINC429
bus data eld.
2-80 MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual
Command Groups
Table 2-41: Trigger Commands (cont.)
Command
Description
TRIGger:A:BUS:B<x>:ARINC429A:DATA:
QUALier
This command sets the qualier (<, >, =, <=, >=, not =, in range, out of range)
to use when triggering on a ARINC429 bus data eld.
TRIGger:A:BUS:B<x>:ARINC429A:DATA:VALue This command species the low value to use when triggering on a ARINC429
bus data eld.
TRIGger:A:BUS:B<x>:ARINC429A:ERRTYPE This command species the error type to use when triggering on a ARINC429
bus signal.
TRIGger:A:BUS:B<x>:ARINC429A:LABel:
HIVALue
This command species the high value to use when triggering on a ARINC429
bus label eld.
TRIGger:A:BUS:B<x>:ARINC429A:LABel:
QUALier
This command sets the qualier (<, >, =, <=, >=, not =, in range, out of range)
to use when triggering on a ARINC429 bus label eld.
TRIGger:A:BUS:B<x>:ARINC429A:LABel:VALue This command species the low value to use when triggering on a ARINC429
bus label eld.
TRIGger:A:BUS:B<x>:ARINC429A:SDI This command species the SDI portion of the packet data to be used when
triggering on ARINC429 bus data.
TRIGger:A:BUS:B<x>:ARINC429A:SSM This command species the SSM portion of the packet data to be used when
triggering on a ARINC429 bus data.
TRIGger:A:BUS:B <x>:AUDio:CONDition This command sets the condition (start of frame o r matching data) to be used
when triggering on an audio bus signal.
TRIGger:A:BUS:B<x>:AUDio:DATa:HIVALue
This command sets the upper word value to be used when triggering on an
audio bus signal.
TRIGger:A:BUS:B <x >:AUD io:D ATa:OFFSet This command sets the data offset value to be used when triggering on an
audio bus signal.
TRIGger:A:BUS:B <x >:AUD io:D ATa:QUALier This command sets the qualier (<, >, =, <=, >=, not =, in range, out of range)
to be used when triggering on an audio bus signal.
TRIGger:A:BUS:B<x>:AUDio:DATa:VALue
This command sets the lower word value to be used when triggering on an
audio bus signal.
TRIGger:A:BUS:B <x>:AUDio:DATa:WORD This command sets the alignment of the data (left, right or either) to be used to
trigger on an audio bus signal.
TRIGger:A:BUS:B <x>:CAN:CONDition This command sets the condition (start of frame, frame type, identier,
matching data, end of frame, missing ACK eld, bit-stufng error, form error,
any error, CAN FD BRS bit, or CAN FD ESI bit) to be used when triggering
on a CAN bus signal.
TRIGger:A:BUS:B <x >:CAN:DATa:DIRection This command sets the data direction (read, write or “nocare”) to be used to
search on a CAN bus signal.
TRIGger:A:BUS:B <x >:CAN:DATa:OFFSet This command species the data offset for CAN data triggering
TRIGger:A:BUS:B <x >:CAN :DATa:QU ALier This command sets the qualier (<, >, =, not =, <=) to be used when triggering
on a CAN bus signal.
TRIGger:A:BUS:B <x>:CAN:DATa:SIZe This command sets the length of the data string, in bytes, to be used when
triggering on a C AN bus signal.
TRIGger:A:BUS:B<x>:CAN:DATa:VALue
This command sets the binary data value to be used when triggering o n a
CAN bus signal.
MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual 2-81
Command Groups
Table 2-41: Trigger Commands (cont.)
Command
Description
TRIGger:A:BUS :B<x>:CAN:FD:BRSBIT This command sets the value (don’t care, 1, or 0) to be used to trigger on
CANFDBRSbits
TRIGger:A:BUS :B<x>:CAN:FD:ESIBIT This command sets the value (don’t care, 1, or 0) to be used to trigger on
CAN FD ESI bits
TRIGger:A:BUS :B<x>:CAN:FRAMEtype This command sets the frame type (data, remote, error or overload) to be used
when triggering on a CAN bus signal.
TRIGger:A:BUS :B<x>:CA N{:IDentier|:ADDRess}:
MODe
This command sets the addressing mode (standard or extended format) to be
used when triggering on a CAN bus signal.
TRIGger:A:BUS :B<x>:CA N{:IDentier|:ADDRess}:
VALue
This command sets the binary address value to be used when triggering on a
CAN bus signal.
TRIGger:A:BUS:B<x>:ETH E R net:C ON Dition This command species a eld or condition within an Ethernet frame to trigger
on.
TRIGger:A:BUS:B<x>:ETHERnet:DATa:HIVALue When the Ethernet trigger condition is set to DATa, and the qualier is set to
either
INrange orOUTrange, this command species the upper data value
of the range.
TRIGger:A:BUS:B<x>:ETHERnet:DATa:OFFSet When the Ethernet trigger condition is set to DATa, this command species
where in the data eld to look for the data trigger value.
TRIGger:A:BUS :B<x>:ETH ER net:DATa:SIZe When the Ethernet trigger condition is set to DATa, this command species
the number of contiguous TCP/IPv4/MA C client data bytes to trigger on.
TRIGger:A:BUS:B<x>:ETHERnet:DATa:VALue When the Ethernet trigger condition is set to DATa, and the qualier is set
to
LESSthan, MOREthan, EQual, UNEQual, LESSEQual or
MOREEQual, this c ommand species the value to trigger on.
TRIGger:A:BUS:B<x>:ETH E R net:FR AM E T YPe This command species the Ethernet frame type: either Basic or QTag (IEEE
802.1Q, or V LAN tagging).
TRIGger:A:BUS:B<x>:ETHERnet:IPHeader:
DESTinationaddr:VALue
When the Ethernet trigger condition is set to
IPHeader, this command
species the value of the 32–bit destination address that is to be used in the
trigger (along with the source address and protocol value).
TRIGger:A:BUS:B<x>:ETHERnet:IPHeader:
PROTOcol:VALue
When the Ethernet trigger condition is set to
IPHeader, this command
species the value of the 8–bit protocol eld that is to be used in the trigger
(along with the source and destination addresses).
TRIGger:A:BUS:B<x>:ETHERnet:IPHeader:
SOUrceaddr:VALue
When the Ethernet trigger condition is set to
IPHeader, this command
species the value of the 32–bit source address that is to be used in the trigger
(along with the destination address and protocol value).
TRIGger:A:BUS:B<x>:ETHERnet:MAC:ADDRe ss:
DESTination:VALue
When the Ethernet trigger condition is set to
MACADDress , this command
species the 48–bit MAC destination address that is to be used in the trigger
(along with the source address value).
TRIGger:A:BUS:B<x>:ETHERnet:MAC:ADDRe ss:
SOUrce:VALue
When the Ethernet trigger condition is set to
MACADDress , this command
species the 48–bit MAC source address value that is to be used in the trigger
(along with the destination address value).
TRIGger:A:BUS:B<x>:ETHERnet:MAC{:LENgth|:
TYPe}:HIVALue
When the Ethernet trigger condition is set to MACLENgth, and the qualier
is set to
INrange or OUTrange, this command species the upper data
value of the range.
2-82 MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual