MDO3000 Programmer Manual.pdf - 第69页
Command Groups T able 2-34: Miscellaneous Commands (cont.) Command Description AUXOut:SOUrce This command speci fi es the source for the auxiliary-out port. CLEARMenu Clears the current m enu from the display DA TE This c…

Command Groups
Table 2-33: Measurement Commands (cont.)
Command
Description
MEASUrement:METHod This command specifies the method used for calculating reference levels
MEASUrement:REFLevel? Returns the current reference level parameters
MEASUrement:REFLevel:ABSolute:
HIGH
This command specifies the top reference level for rise time
MEASUrement:REFLevel:ABSolute:
LOW
This command specifies the low reference level for rise time
MEASUrement:REFLevel:ABSolute:
MID<x>
This command specifies the mid reference level for the specified channel in absolute volts
MEASUrement:REFLevel:METHod This command specifies the method for assigning high and low reference levels
MEASUrement:REFLevel:PERCent:
HIGH
This command specifies the top reference percent level for rise time
MEASUrement:REFLevel:PERCent:
LOW
This command specifies the low reference percent level for rise time
MEASUrement:REFLevel:PERCent:
MID<x>
This command specifies the mid reference level for the specified channel in percent
MEASUrement:STATIstics Clears or returns all of the statistics accumulated for all period m easurements (MEAS1
through MEAS4)
MEASUrement:STATIstics:MODe Turns measurement statistics on or off
MEASUrement:STATIstics:
WEIghting
Controls the responsiveness of the mean and standard deviation to waveform changes
Miscellaneous Command Group
Use the commands in the Miscellaneous Command Group to perform actions that
do not fit into other categories.
Table 2-34: Miscellaneous Commands
Command
Description
APPLication:LICENSE:SLOT<x>:
LOCation?
This query returns the application license l ocation. < x> can be slot number 1–4.
APPLication:LICENSE:SLOT<x>:
TRANSFER
You can use this command to transfer an application license from the module to internal
memory in the oscilloscope, and transfer it back.
APPLication:LICENSE:SLOT<x>:
TYPe?
This query returns the application license type of the module that is currently inserted in the
specified application module slot.
APPLication:TYPe
When a m ask/limit or power test application module is installed, one of the associated test
types is always selected by default. This command allows the test type to be changed
from the default.
AUTOSet Sets the vertical, horizontal and trigger controls to provide a stable display of the appropriate
waveform. This is equivalent to pressing the front panel Autoset button
AUTOSet:ENAble Enables or disables the autoset feature
2-38 MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual

Command Groups
Table 2-34: Miscellaneous Commands (cont.)
Command
Description
AUXOut:SOUrce This command specifies the source for the auxiliary-out port.
CLEARMenu Clears the current menu from the display
DATE
This command specifies the date displayed by the oscilloscope
*DDT This command specifies the commands that will be executed by the group execute trigger
DESkew Causes the deskew values for all channels to be set to the recommended values
DISplay:INTENSITy:B A CK Light:
AUTODim:TIMe
This command specifies the state of the deskew table display
ETHERnet:LXI:LAN:PASSWord:
ENABle
This command controls whether LXI (LAN eXtensions for Instrumentation) is password
protected.
ETHERnet:LXI:LAN:PASSWord:
ESCOPEENABle
This command controls whether to use the LXI password for e*Scope (effectively equal
to enabling password protection for e*Scope). With e*Scope, you can access any
Internet-connected MSO /DPO 4000B or MDO4000/B/C Series Oscilloscope from a web
browser.
ETHERnet:LXI:LAN:RESET
This com m and resets the LXI local area network. The items which this command reset
include: DHCP/BOOTP, mDNS and DNS-SD, e*S cope password protection, LXI password
protection, and e*Scope and LXI password.
ETHERnet:LXI:LAN:SERVICENAMe This command specifies the mDNS service name used for the LXI interface.
ETHERnet:LXI:LAN:STATus?
This query returns the LXI network status.
ETHERnet:NETWORKCONFig This command specifies the Ethernet network configuration setting.
FPAnel:HOLD This command is used to emulate the push-and-hold feature of the Cursor button.
FPAnel:PRESS Simulates the action of pressing a specified front-panel button
FPAnel:TURN
Simulates the action of turning a specified front-panel control knob
GPIBUsb:ADDress? Returns the current GPIB address
GPIBUsb:ID? Returns the identification string of the connected adaptor module and firmware version
HEADer|:HDR This command specifies the R esponse Header Enable State
ID? Returns the instrument identification data similar to that returned by the *IDN? IEEE488.2
common query, including the addition of any enabled application modules. However, it does
not include the instrument serial number.
*IDN? Returns the same information as the ID? command except the data is formatted according
to Tektronix Codes & Formats
LANGuage This command specifies the user interface display language
LOCk This command specifi es the front panel lock state
*LRN? Returns a listing of oscilloscope settings
NEWpass
Changes the password for user protected data
PASSWord Enables the *PUD and NEWpass set commands
PAUSe This command causes the interface to pause the specified number of seconds before
processing any other commands.
REBOOT Performs a reboot of the instrument after a short delay.
REM
Specifies a comment, which is ignored by the oscilloscope
MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual 2-39

Command Groups
Table 2-34: Miscellaneous Commands (cont.)
Command
Description
ROSc:SOUrce This command specifies the source for the time base reference oscillator. The reference
oscillator locks to this source. Depending on the command argument that you specify,
you can use an external reference or use the internal crystal oscillator as the time base
reference.
ROSc:STATE? This query returns an enumeration value that indicates the lock state of the reference
oscillator specifi ed by the
ROSc:SOUrce command.
SET? Returns a listing of oscilloscope setti ngs
SOCKETServer:ENAble
This command enables or disables the socket s erver which supports a Telnet or other
TCPIP socket connection to send commands and queries to the instrument.
SOCKETServer:PORT This command sets the TCPIP port for the socket server connection.
SOCKETServer:PROTOCol This comma nd sets the protoco l for the socket server.
TEKSecure Initializes both waveform and setup memories
TIMe
This command specifies the time displayed by the oscilloscope
TOTaluptime? Returns the total number of hours that the oscilloscope has been turned on since the
nonvolatile memory was last programmed
*TRG Performs the group execute trigger (G ET)
*TST? Tests the interface and returns the status
UNLock
Unlocks front panel
USBTMC? Returns the USBTMC information used by the USB hosts to determine the instrument
interfaces.
USBTMC:PRO DU CTID:DECimal?
This query returns the product ID number as a decimal.
USBTMC:PRODUCTID:
HEXadecimal?
This query returns the product ID number as a decimal.
USBTMC:SERIALnumber? This query returns the serial number of the oscilloscope.
USBTMC:VENDORID:DECimal?
This query returns the vendor ID number as a decimal.
USBTMC:VENDORID:HEXadecimal?
This query returns the vendor ID number as a hexadecimal value. The hexadecimal vendor
ID for Tektronix instruments is 0x699.
VERBose
This command specifies the verbose state
PictBridge Command Group
Use the commands in the PictBridge Command Group to store printer settings.
Table 2-35: PictBridge Commands
Command
Description
PICTBridge:DATEP rint
Enables or disables printing the date on the print output
PICTBridge:DEFault Sets the arguments for all PICTBridge commands to their default values
PICTBridge:IDPrint
Enables or disables printing the oscilloscope model and serial number on the print output
PICTBridge:IMAGESize This command specifies the image print size
2-40 MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual