MDO3000 Programmer Manual.pdf - 第684页

Commands Listed in A lphabetical Order SEARCH:SEARCH 1:TRIGGER:A:BUS: B1:FLEXRAY:DATA :SIZE? might return SEARCH:SEARCH 1:TRIGGER:A:BUS: B1:FLEXRAY:DATA :SIZE 1 indicating the data size is 1 byte. SEARCH:SEAR CH<x>…

100%1 / 1158
Commands Listed in Alphabetical Order
Arguments
LESSthan sets t
he data qualifier to less than.
MOREthan sets the data qualifier to greater than.
EQual sets the data qualifier to equal.
UNEQual sets the data qualifier to not equal.
LESSEQual sets the data qualifier to less than or equal.
MOREEQual sets the data qualifier to greater than or equal.
INrange sets the data qualifier to in range.
OUTrange s
ets the data qualifier to out of range.
Examples
SEARCH:SEARCH1:TRIGGER:A:BUS:B1:FLEXRAY:DATA:QUALIFIER
LESSTHAN
sets the data qualifier to less than.
SEARCH:SEARCH1:TRIGGER:A:BUS:B1:FLEXRAY:DATA:QUALIFIER? might
return
SEARCH:SEARCH1:TRIGGER:A:BUS:B1:FLEXRAY:DATA:QUALIFIER
EQUAL
indicating the data qualifier is =.
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:FLEXray:DATa:SIZe
This command specifies the length of the data string, in bytes, to use when
searching on the Fl
exRay bus data field. The search condition needs to be set to
ID or IDANDDATA (using SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:
FLEXray:CONDition).
SEARCH<x> is the search number, which is always 1,
and
B<x>
Conditions
This command requires a DPO4AUTOMAX application module for
DPO/MSO4000B and MDO4000/B/C models or MDO3FLEX application module
for MDO3000 models.
Group
Search
Syntax
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:FLEXray:DATa:SIZe <NR1>
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:FLEXray:DATa:SIZe?
Arguments
<NR1> is the length of the data string in bytes. Length range is 1 to 8.
Examples
SEARCH:SEARCH1:TRIGGER:A:BUS:B1:FLEXRAY:DATA:SIZE 8 sets the
data size to 8 bytes.
MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual 2-653
Commands Listed in Alphabetical Order
SEARCH:SEARCH
1:TRIGGER:A:BUS:B1:FLEXRAY:DATA:SIZE?
might return
SEARCH:SEARCH1:TRIGGER:A:BUS:B1:FLEXRAY:DATA:SIZE 1 indicating
the data size is 1 byte.
SEARCH:SEAR
CH<x>:TRIGger:A:BUS:B<x>:FLEXray:DATa:VALue
This command specifies the low value to use when searching on the FlexRay bus
data field. The search condition needs to be set to ID or IDANDDATA (using
TRIGger:A
:BUS:B<x>:FLEXray:CONDition).
SEARCH<x> is the search number,
whichisalways1,and
B<x>
Conditions
This command requires a DPO4AUTOMAX application module for
DPO/MSO4000B and MDO4000/B/C models or MDO3FLEX application module
for MDO3000 models.
Group
Search
Syntax
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:FLEXray:DATa:VALue
<QString>
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:FLEXray:DATa:VALue?
Re
lated Commands
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:FLEXray:CONDition
Arguments
<QString> is a quoted string that is the low binary data string to be used for a
FlexRay search if the search condition is set to
IDANDDATA.
Examples
SEARCH:SEARCH1:TRIGGER:A:BUS:B1:FLEXRAY:DATA:VALUE
“11001010”
sets the binary data string to 11001010.
SEARCH:SEARCH1:TRIGGER:A:BUS:B1:FLEXRAY:DATA:VALUE? might
return
SEARCH:SEARCH1:TRIGGER:A:BUS:B1:FLEXRAY:DATA:VALUE
"XXXXXXXX"
indicates the binary data string is don't cares.
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:FLEXray:EOFTYPE
This command specifies which end of file type to use (static, dynamic or any)
when searching on the FlexRay bus EOF field. The search condition needs to be
set to EOF (using SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:FLEXray:
CONDition).
SEARCH<x> is the search number, which is always 1, and B<x>
2-654 MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual
Commands Listed in Alphabetical Order
Conditions
This command re
quires a DPO4AUTOMAX application module for
DPO/MSO4000B and MDO4000/B/C models or MDO3FLEX application module
for MDO3000 models.
Group
Search
Syntax
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:FLEXray:EOFTYPE
{STATic|DYNAMic|ANY}
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:FLEXray:EOFTYPE?
Arguments
STATic sets the FlexRay end of frame type to STATIC.
DYNAMic sets the FlexRay end of frame type to DYNAMIC.
ANY sets the FlexRay end of frame type to ANY type.
Examples
SEARCH:SEARCH1:TRIGGER:A:BUS:B1:FLEXRAY:EOFTYPE ANY sets the
FlexRay end of frame type to any type.
SEARCH:SEARCH1:TRIGGER:A:BUS:B1:FLEXRAY:EOFTYPE? might return
SEARCH:SEARCH1:TRIGGER:A:BUS:B1:FLEXRAY:EOFTYPE STATIC
indicating the FlexRay end of frame type is static.
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:FLEXray:ERRTYPE
This command specifies the error type to use when searching on the
FlexRay bus signal. The search condition needs to be set to ERROR (using
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:FLEXray:CONDition).
SEARCH<x> is the search number, which is always 1, and B<x>
Conditions
This command requires a DPO4AUTOMAX application module for
DPO/MSO4000B and MDO4000/B/C models or MDO3FLEX application module
for MDO3000 models.
Group
Search
Syntax
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:FLEXray:ERRTYPE
{CRCHeader|CRCTrailer|SYNCFrame|STARTupnosync|NULLFRStatic|
NULLFRDynamic}
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:FLEXray:ERRTYPE?
MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual 2-655