MDO3000 Programmer Manual.pdf - 第207页
Commands Listed in Alphabetical Order Group Bus Syntax BUS:B<x>:ETHE Rnet:SOUrce:DPLU s {CH1|CH2|C H3|CH4|D0|D1|D2| D3| D4|D5|D6|D7|D 8|D9|D10|D11|D12 |D13|D14|D15} BUS:B<x>:ETHE Rnet:SOUrce:DPLU s? Related C…

Commands Listed in Alphabetical Order
BUS:B1:ETHERn
et:SOUrce:DIFFerential?
might return CH2, indicating
that channel 2 is the currently specified source for Ethernet data differential input.
BUS:B<x>:ETHERnet:SOUrce:DMINus
This command specifies the Ethernet data source for D- input for single-ended
probing. The default is Channel 2.
Conditions
This command requires a DPO4ENET application module for DPO/MSO4000B
and MDO4000/B/C models.
Group
Bus
Syntax
BUS:B<x>:ETHERnet:SOUrce:DMINus {CH1|CH2|CH3|CH4|D0|D1|D2|D3
|D4|D5|D6|D7|D8|D9|D10|D11|D12|D13|D14|D15}
BUS:B<x>:ETHERnet:SOUrce:DMINus?
Related Commands
BUS:B<x>:ETH
ERnet:PRObe
BUS:B<x>:ETHERnet:SOUrce:DPLUs
Arguments
CH1–4 specifies to use one of the analog channels as the Ethernet data source
for the D- input.
D0–D15 specifies to use one of the digital channelsD0–D15astheEthernetdata
source for the D- input. (MSO/MDO4000/B/C models only. )
Examples
BUS:B1:ETHERnet:SOUrce:DMINus D5 specifies the Ethernet data source
for the D- input as D5.
BUS:B1:ETHERnet:SOUrce:DMINus? might return CH3, indicating that
channel 3 is the Ethernet data source for the D- input.
BUS:B<x>:ETHERnet:SOUrce:DPLUs
This command specifies the Ethernet data source for the D+ input for single-ended
probing. The default is channel 1.
Conditions
This command requires a DPO4ENET application module for DPO/MSO4000B
and MDO4000/B/C models.
2-176 MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual

Commands Listed in Alphabetical Order
Group
Bus
Syntax
BUS:B<x>:ETHERnet:SOUrce:DPLUs {CH1|CH2|CH3|CH4|D0|D1|D2|D3|
D4|D5|D6|D7|D8|D9|D10|D11|D12|D13|D14|D15}
BUS:B<x>:ETHERnet:SOUrce:DPLUs?
Related Commands
BUS:B<x>:ETHERnet:PRObe
BUS:B<x>:ETHERnet:SOUrce:DMINus
Arguments
CH1–4 specifies to use one of the analog channels 1–4 as the Ethernet data source
for the D+ input.
D0–D15 specifies to use one of the digital channels D0 — D15 as the Ethernet
data source for the D+ input. (MSO/MDO4000/B models only as well as
MDO3000 and MDO400C models with option MDO3MSO or MDO4MSO
installed.)
Examples
BUS:B1:ETHERnet:SOUrce:DPLUs D5 specifies the Ethernet data source for
the D+ input as D5.
BUS:B1:ETHERnet:SOUrce:DPLUs? might return CH3, indicating that channel
3 is the Ethernet data source for the D+ input.
BUS:B<x>:ETHERnet:TYPe
This command specifies the Ethernet standard type: 10Base-T or 1
00Base-T.
The default is ENET 100 BASETX.
Conditions
This command requires a DPO4ENET application module for DPO/MSO4000B
and MDO4000/B/C models.
Group
Bus
Syntax
BUS:B<x>:ETHERnet:TYPe {ENET10BASET|ENET100BASETX}
BUS:B<x>:ETHERnet:TYPe?
Related Commands
BUS:B<x>:ETHERnet:PRObe
TRIGger:A:BUS:B<x>:ETHERnet:CONDition
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:ETHERnet:CONDition
MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual 2-177

Commands Listed in Alphabetical Order
Arguments
ENET10BASET sp
ecifies the Ethernet type as 10Base-T standard. This standard
supports data transfer rates up to 10 Mbps (also called Twisted Pair Ethernet).
ENET100BASET
X
specifies the Ethernet type as 100Base-T standard. This
standard supports data transfer rates up to 100 Mbps (also called Fast Ethernet).
Examples
BUS:B1:ETHERnet:TYPe ENET100BASETX specifies the Ethernet type as
100Base-T.
BUS:B1:ETHERnet:TYPe? might return ENET10BASET, indicating that the
Ethernet type has been set to 10Base-T.
BUS:B<x>:FLEXray:BITRate
Specifies the bit rate for the FlexRay bus signal. The maximum bitrate is
100 Mbps.
Conditions
This command requires a DPO4AUTOMAX application module for 4000 series
models, and MDO3FLEX application module for MDO3000 series models.
Group
Bus
Syntax
BUS:B<x>:FLEXray:BITRate <NR1>
BUS:B<x>:FLEXray:BITRate?
Arguments
<NR1> specifies the FlexRay bus bit rate. You can enter any positive integer, and
the instrument will coerce the value to the closest supported bit rate.
Examples
BUS:B1:FLEXRAY:BITRATE 9600 sets the FlexRay bus bit rate to 9600 bits per
second.
BUS:B1:FLEXRAY:BITRATE? might return BUS:B1:FLEXRAY:BITRATE
10000000
indicating the FlexRay bit rate is 10,000,000 bits per second.
BUS:B<x>:FLEXray:CHannel
Specifies the FlexRay bus ID format.
Conditions
This command requires a DPO4AUTOMAX application module for 4000 series
models, and MDO3FLEX application module for MDO3000 series models.
2-178 MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual