MDO3000 Programmer Manual.pdf - 第116页

Command Groups T able 2-41: T rigger Commands (cont.) Command Description TRIGger:A:BUS:B<x>:MIL1553B:ST A T us:BIT : DBCA When the MIL-STD-1553 bus trigger condition is set to STATus , this command speci fi es the …

100%1 / 1158
Command Groups
Table 2-41: Trigger Commands (cont.)
Command
Description
TRIGger:A:BUS:B<x>:MIL1553B :CO MMAND:
ADDRess:HIVALue
When the M IL-STD-1553 bus trigger condition is set to COMMAN D, and the
qualier is set to
INrange or OUTrange, this command species the upper
limit of the range for the remote terminal address eld.
TRIGger:A:BUS:B<x>:MIL1553B :CO MMAND:
ADDRess:QUALier
When the MIL-STD-1553 bus trigger condition is set to COMMAND,this
command species the qualier to be used with the remote terminal address
eld.
TRIGger:A:BUS:B<x>:MIL1553B :CO MMAND:
ADDRess:VALue
When the MIL-STD-1553 bus trigger condition is set to COMMAND,and
the qualier is set to
LESSthan, MOREthan, EQual, UNEQual,
LESSEQual
or MOREEQual, this command species the value of the 5–bit
remote terminal address to be used in the trigger.
TRIGger:A:BUS:B<x>:MIL1553B :CO MMAND:
COUNt
When the MIL-STD-1553 bus trigger condition is set to COMMAND,this
command species the bit pattern for the 5–bit Word C ount/Mode Code
sub-address eld that is to be used in the trigger.
TRIGger:A:BUS:B<x>:MIL1553B :CO MMAND:
PARity
When the MIL-STD-1553 bus trigger condition is set to COMMAND,this
command species the Command word parity that is to be used in the trigger.
TRIGger:A:BUS:B<x>:MIL1553B :CO MMAND:
SUBADdress
When the MIL-STD-1553 bus trigger condition is set to COMMAND,this
command species the 5 bit s ub-address that is to be used in the trigger.
TRIGger:A:BUS:B<x>:MIL1553B :CO MMAND:
TRBit
When the MIL-STD-1553 bus trigger condition is set to COMMAND,this
command species that the transmit/receive bit (bit 9) is to be used in the
trigger.
TRIGger:A:BUS:B<x>:MIL1553B :CONDition This command species a word type or condition within a MIL-STD-1553 bus
word to trigger on.
TRIGger:A:BUS:B<x>:MIL1553B :DATa:PARity When the MIL-STD-1553 bus trigger condition is set to DATa, this c ommand
species the data parity bit to be used in the trigger.
TRIGger:A:BUS:B<x>:MIL1553B :DATa:VALue When the MIL-STD-1553 bus trigger condition is set to DATa, this command
species the data binary pattern to be used in the trigger.
TRIGger:A:BUS:B<x>:MIL1553B :ERRTYPE When the MIL-STD-1553 bus trigger condition is set to ERRor, this command
species the signaling error type to be used in the trigger: Parity, Sync,
Manchester or Data.
TRIGger:A:BUS:B<x>:MIL1553B :STATus:
ADDRess:HIVALue
When the MIL-STD-1553 bus trigger condition is set to STATus, and the
qualier is set to
INrange or OUTrange, this command species the upper
limit for the 5 bit remote terminal address eld of the Status word.
TRIGger:A:BUS:B<x>:MIL1553B :STATus:
ADDRess:QUALier
When the MIL-STD-1553 bus trigger condition is set to STATus, this command
species the qualier to be used with the address eld.
TRIGger:A:BUS:B<x>:MIL1553B :STATus:
ADDRess:VALue
When the MIL-S TD-1553 bus trigger condition is set to STATus, and
the qualier is set to
LESSthan, MOREthan, EQual, UNEQual,
LESSEQual
or MOREEQual, this command species the value of the 5–bit
remote terminal address to be used in the trigger.
TRIGger:A:BUS:B<x>:MIL1553B :STATus:BIT:BCR When the MIL-STD-1553 bus trigger condition is set to STATus, this command
species the status word broadcast command received (BCR) bit value (bit
15) to be used in the trigger.
TRIGger:A:BUS:B<x>:MIL1553B :STATus:BIT:
BUSY
When the MIL-STD-1553 bus trigger condition is set to STATus, this command
species the status word busy bit value (bit 16) to be used in the trigger.
MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual 2-85
Command Groups
Table 2-41: Trigger Commands (cont.)
Command
Description
TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:
DBCA
When the MIL-STD-1553 bus trigger condition is set to STATus, this command
species the status word dynamic bus contro l acceptance (DBCA) bit value (bit
18) to be used in the trigger.
TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:
INSTR
When the MIL-STD-1553 bus trigger condition is set to STATus,this
command species the status word instrumentation bit value (bit 10) to be
used in the trigger.
TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:ME When the MIL-STD-1553 bus trigger condition is set to STATus,this
command species the status word message error bit value ( bit 9) to be used
in the trigger.
TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:SRQ When the MIL-STD-1553 bus trigger condition is set to STATus, this command
species the status w ord service request (SRQ) bit value (bit 11) to be used
in the trigger.
TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:
SUBSF
When the MIL-STD-1553 bus trigger condition is set to STATus,this
command species the status word subsystem ag bit value (bit 17) to be
used in the trigger.
TRIGger:A:BUS:B<x>:MIL1553B:STATus:BIT:TF When the M IL-STD-1553 bus trigger condition is set to STATus, this command
species the status word terminal ag bit value (bit 19) to be used in the trigger.
TRIGger:A:BUS:B<x>:MIL1553B:STATus:PARity When the MIL-STD-1553 bus trigger condition is set to STATus, this command
species the status parity bit value to be used in the trigger.
TRIGger:A:BUS:B<x>:MIL1553B:TIMe:LESSLimit When the MIL-STD-1553 bus trigger condition is set to TIMe, this command
species either the minimum remote terminal response time (RT) limit for
the amount of time the terminal has to transmit, or it species the minimum
inter-message gap (IMG).
TRIGger:A:BUS:B<x>:MIL1553B:TIMe:MORELimit When the MIL-STD-1553 bus trigger condition is set to TI Me, this command
species either the maximum remote terminal response time (RT) limit for
the amount of time the terminal has to transmit, or it species the maximum
inter-message gap (IMG).
TRIGger:A:BUS:B<x>:MIL1553B:TIMe:QUALier When the MIL-STD-1553 bus trigger condition is set to TIMe, this command
species the trigger data time qualier.
TRIGger:A:BUS:B<x>:PARallel:VALue This command species the binary data string to b e u sed for a Parallel trigger
TRIGger:A:BUS:B<x>:RS232C:CONDition This command species the condition for an RS-232C trigger
TRIGger:A:BUS:B<x>:RS232C:RX:DATa:SIZe This command species the length of the data string in Bytes for an RX
RS-232 Trigger
TRIGger:A:BUS:B<x>:RS232C:RX:DATa:VALue This command species the binary data string for an RX RS-232 trigger
TRIGger:A:BUS:B<x>:RS232C:TX:DATa:SIZe This command species the length of the data string for a TX RS-232 trigger
TRIGger:A:BUS:B<x>:RS232C:TX:DATa:VALue This command species the binary data string for an RS-232 trigger if the
trigger condition involves TX
TRIGger:A:BUS:B<x>:SPI:C ONDition This command species the trigger condition for SPI triggering
TRIGger:A:BUS :B<x>:SPI:D ATa{:IN|:MISO}:
VALue
This command species the binary data string to be used for S PI trigger
TRIGger:A:BUS :B<x>:SPI:DATa{:OUT|:MOSI}:
VALue
This command species the binary data string used for the SPI trigger
2-86 MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual
Command Groups
Table 2-41: Trigger Commands (cont.)
Command
Description
TRIGger:A:BUS:B <x>:SPI:DATa:SIZe This command species the length of the data s tring in bytes to be used for
SPI trigger
TRIGger:A:BUS:B <x >:USB:ADDRess:HIVALue This command species the high limit for the USB trigger address
TRIGger:A:BUS:B<x>:USB :ADDRess:VALue This command species the value for the USB trigger address
TRIGger:A:BUS:B <x>:USB:CONDition This command species the USB trigger condition
TRIGger:A:BUS:B<x>:USB :DATa:HIVALue This command speci es the high limit for the USB trigger data
TRIGger:A:BUS:B <x>:USB:DATa:OFFSet This command species the data offset for the U SB trigger data
TRIGger:A:BUS:B <x>:USB:DATa:SIZe This command species the number of data bytes for the USB trigger
TRIGger:A:BUS:B <x>:USB:DATa:TYPe This command species the data type for the USB trigger
TRIGger:A:BUS:B <x>:USB:DATa:VALue This command species the data value for the USB trigger
TRIGger:A:BUS:B<x>:USB :ENDPoint:VALue This command species the endpoint value for the USB trigger
TRIGger:A:BUS:B <x>:USB:ERRTYPE This command species the error type for the USB trigger
TRIGger:A:BUS:B<x>:USB :HANDSHAKEType This command species the handshake type for the USB trigger
TRIGger:A:BUS:B <x >:USB:QUALier This command species the qualier for USB trigger
TRIGger:A:BUS:B <x >:USB:SOFFRAMENUMber This command species the SOF number for the USB trigger
TRIGger:A:BUS:B<x>:USB :SPECIALType This command species the special packet type for the USB trigger
TRIGger:A:BUS:B<x>:USB :SPLit:ET:VALue When triggering on a high-speed USB split transaction, this command species
the split transaction endpoint type value to trigger on.
TRIGger:A:BUS:B<x>:USB :SPLit:HUB:VALue When triggering on a high-speed USB split transaction, this command species
the split transaction hub address value to trigger on.
TRIGger:A:BUS:B<x>:USB :SPLit:PORT:VALue When triggering on a high-speed USB split transaction, this command species
the split transaction port address value to trigger on.
TRIGger:A:BUS:B<x>:USB :SPLit:SC:VALue When triggering on a high-speed USB split transaction, this command species
whether to trigger on the start or complete phase of the split transaction, based
on the Start/Complete bit eld value.
TRIGger:A:BUS:B<x>:USB :SPLit:SE:VALue When triggering on a high-speed USB split transaction, this command species
the split transaction start/end bit value to trigger on.
TRIGger:A:BUS:B <x>:USB:TOKENType This command speci es the token type for the USB trigger
TRIGger:A:BUS:S OUrce This command species the source for a bus trigger
TRIGger:A:EDG E? Returns the source, coupling and source for the A edge trigger
TRIGger:A:EDGE:COUPling This command species the type of coupling for the A edge trigger
TRIGger:A:EDGE:SLOpe This command species the slope for the A edge trigger: rising, falling or either.
TRIGger:A:EDGE:SOUrce This command species the source for the A edge trigger
TRIGger:A:HOLDoff? Returns the A trigger holdoff parameters
TRIGger:A:HOLDoff:TIMe This command species the A trigger holdoff time
TRIGger:A:LEVel:AUXin Sets the threshold v oltage level for an Edge, Pulse Width, Runt or Rise/Fall
(aka Transition, aka Slew Rate) trigger to use when triggering on the Aux
Input connector signal.
MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual 2-87