MDO3000 Programmer Manual.pdf - 第184页
Commands Listed in A lphabetical Order Group V ertical Syntax AUXin:PRObe:G AIN <NR3> AUXin:PRObe:G AIN? Arguments <NR3> is a floating point number that specifies the probe gain, which is probe dependen t. Exam…

Commands Listed in Alphabetical Order
AUXin:PRObe:
DEGAUss:STATE? (Query Only)
Returns the state of the probe degauss (NEEDED, RECOMMENDE D, PASSED,
FAILED, RUNNING). The command will return PASSED for probes that do not
support dega
uss operations.
Conditions
Available for MSO/DPO4000B series models, 2-channel MDO3000 models, and
MDO4000C m
odels without option SA3 or SA6 only.
Group
Vertical
Syntax
AUXin:PRObe:DEGAUss:STATE?
Example
s
AUXin:PROBE:DEGAUSS:STATE? might return:
AUXin:PROBE:DEGAUSS:STATE PASSED indicating that the probe has been
degaussed.
AUXin:PRObe:FORCEDRange
Changes or returns the range on a TekVPI probe attached to the A
ux Input
connector.
Conditions
Available for MSO/DPO4000B series models, 2-channel MDO30
00 models, and
MDO4000C models without option SA3 or SA6 only.
Group
Vertical
Syntax
AUXin:PRObe:FORCEDRange <NR3>
AUXin:PRObe:FORCEDRange?
Arguments
<NR3> is a floating point number that specifies the probe range, which is probe
dependent.
AUXin:PRObe:GAIN
Specifies the gain factor of a probe that is attached to the Aux Input connector.
Conditions
Available for MSO/DPO4000B series models, 2-channel MDO3000 models, and
MDO4000C models without option SA3 or SA6 only.
MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual 2-153

Commands Listed in Alphabetical Order
Group
Vertical
Syntax
AUXin:PRObe:GAIN <NR3>
AUXin:PRObe:GAIN?
Arguments
<NR3> is a floating point number that specifies the probe gain, which is probe
dependent.
Examples
AUXin:PROBE:GAIN? might return 100.0000E-3 indicating that the attached
10x probe delivers 0.1 V to the Aux In BNC for every 1.0 V applied to the probe
input.
AUXin:PRObe:ID:SERnumber? (Query Only)
Returns the serial number of the probe that is attached to the Aux Input connector.
Conditions
Available for MSO/DPO4000B series models, 2-channel MDO3000 models, and
MDO4000C models without option SA3 or SA6 only.
Group
Vertical
Syntax
AUXin:PRObe:ID:SERnumber?
AUXin:PRObe:ID:TYPe? (Query Only)
Returns the type of probe that is attached to the Aux Input connector.
Conditions
Available for MSO/DPO4000B series models, 2-channel MDO3000 models, and
MDO4000C models without option SA3 or SA6 only.
Group
Vertical
Syntax
AUXin:PRObe:ID:TYPe?
AUXin:PRObe:RESistance? (Query Only)
Returns the resistance of the probe attached to the front panel Aux In
connector.
2-154 MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual

Commands Listed in Alphabetical Order
Conditions
Available for M
SO/DPO4000B series models, 2-channel MDO3000 models, and
MDO4000C models without option SA3 or SA6 only.
Group
Vertical
Syntax
AUXin:PRObe:RESistance?
Examples
AUXin:PRObe:RESistance? might return :AUXin:PROBE:RESISTANCE
1.0000E+6
indicat
ing that the input resistance of the probe attached to the front
panel Aux In connector is 1 MΩ.
NOTE. This query will return 0.0 if no probe is attached or the attached probe
does not report the input resistance.
AUXin:PRObe:SIGnal
This command ch
anges the input bypass setting on VPI probes that support input
bypass, for example the TCP0001. If sent to a probe that does not support input
bypass, it is ignored.
Conditions
Available for MSO/DPO4000B series models, 2-channel MDO3000 models, and
MDO4000C models without option SA3 or SA6 only.
Group
Vertical
Syntax
AUXin:PRObe:SIGnal {BYPass|PASS}
AUXin:PRObe:SIG
nal?
Arguments
ByPass sets the probe to Bypass mode.
PASS sets the probe to Pass mode.
AUXin:PRObe:UNIts? (Query Only)
Returns a string describing the units of measure of the probe attached to theAux
Input connector.
Conditions
Available for MSO/DPO4000B series models, 2-channel MDO3000 models, and
MDO4000C models without option SA3 or SA6 only.
MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual 2-155