MDO3000 Programmer Manual.pdf - 第161页
Commands Listed in Alphabetical Order Frequency Function Min Max Resolution SINE 0.1Hz 50MHz 0.1Hz SQUare PULSe ARBitrary 0.1Hz 25MHz 0.1Hz LORENtz GAUSsian ERISe EDECAy NOISe 1 DC 1 HA VERSINe 0.1Hz 5MHz 0.1Hz SINC (Sin…

Commands Listed in Alphabetical Order
Group
ARB
Syntax
AFG.ARBitrary.EMEM.POINTS.BYTEORDer <LSB> |<MSB>
AFG.ARBitrary.EMEM.POINTS.BYTEORDer?
Arguments
LSB – Least significant byte first (little endian)
MSB – Most significant byte first (big endian)
AFG:ARBitrary:EMEM:POINTS:ENCdg
This command specifies the data encoding format for the AFG:ARBitrary:EMEM:
POINTS query (either ASCII or binary).
The default is ASCii. This setting is non-volatile and is reset by default setup
or TekSecure.
Refer to the AFG:ARBitrary:EMEM:POINTS command description for more
information.
Conditions
MDO3000 series with option MDO3AFG installed and MDO4000C series with
option MDO4AFG installed only.
Group
ARB
Syntax
AFG:ARBitrary:EMEM:POINTS:ENCdg {ASCii|BINary}
AFG:ARBitrary:EMEM:POINTS:ENCdg?
Arguments
ASCii –ASCIINR3format
BINary – IEEE488.2 binary block in 4-byte floating point format.
Examples
AFG:ARB:EMEM:POINTS:ENC ASC sets the data encoding format for the
:AFG:ARBitrary:EMEM:POINTS? querytoASCII.
AFG:FREQuency
Sets (or queries) the AFG frequency, in Hz. The following frequency values
canbesetforeachAFGfunction(usethecommandAFG:FUNCtion to select a
function):
2-130 MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual

Commands Listed in Alphabetical Order
Frequency
Function Min Max Resolution
SINE
0.1Hz 50MHz 0.1Hz
SQUare
PULSe
ARBitrary
0.1Hz 25MHz 0.1Hz
LORENtz
GAUSsian
ERISe
EDECAy
NOISe
1
DC
1
HAVERSINe
0.1Hz 5MHz 0.1Hz
SINC (Sin
(x)/x)
0.1Hz 2MHz 0.1Hz
CARDIac
RAMP
0.1Hz 500kHz 0.1Hz
1
DC and NOISe waveforms do not use the frequency setting. Frequency settings that are set when the
AFG:FUNCtion is DC or NOISe are remembered and applied when the function is changed to other than DC
or NOISe.
Conditions
MDO3000 series with option MDO3AFG installed and MDO4000C series with
option MDO4AFG installed only.
Group
AFG
Syntax
AFG:FREQuency <NR3>
AFG:FREQuency?
Arguments
Floating point number that represents the AFG frequency, in Hz.
Returns
Query response is returned in high precision NR3 format (up to 12 digits with
more than 4 trailing 0 digits after the decimal point is omitted).
Examples
AFG:FREQUENCY 100.0E3 sets the AFG frequency to 100 kHz.
AFG:FUNCtion
Sets (or queries) which AFG function to execute.
MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual 2-131

Commands Listed in Alphabetical Order
NOTE. The DC lev
el is controlled by AFG:OFFSet.
Conditions
MDO3000 series with option MDO3AFG installed and MDO4000C series with
option MDO4A
FG installed only.
Group
AFG
Syntax
AFG:FUNCtion
{SINE|SQUare|PULSe|RAMP|NOISe|DC|SINC|GAUSsian|LORENtz
|ERISe|EDECAy|HAVERSINe|CARDIac|ARBitrary}
AFG:FUNCtion?
Arguments
SINE
SQUare
PULSe
RAMP
NOISe
DC – The DC level is controlled by AFG:OFFSet.
SINC (Sin(x)/x)
GAUSsian
LORENtz
ERISe
EDECAy
HAVERSINe
CARDIac
ARBitrary
Examples
AFG:FUNC LOREN specifies to generate the Lorentz function.
AFG:HIGHLevel
This command sets (or queries) the high level value of the output waveform, in
volts, when using the arbitrary function generator feature. The high levelvalue
is constrained by the requirements for amplitude and offset; updating thisvalue
changes the amplitude and offset values.
2-132 MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual