MDO3000 Programmer Manual.pdf - 第472页
Commands Listed in A lphabetical Order MEASUrement: MEAS<x>:UNIts? (Query Only) Returns the units associated with the specified m easurement. The measurem ent slots are specified by <x>, which ranges from 1 thr…

Commands Listed in Alphabetical Order
PHAse measures
the phase difference (amount of time a waveform leads or lags
the reference waveform) between two waveforms. The measurement is made
between the middle reference points of the two waveforms and is expressed in
degrees, where 360° represents one waveform cycle.
PK2Pk (peak-to-peak) finds the absolute difference between the maximum and
minimum amplitude in the entire waveform or gated region. This measurementis
applicable only to the analog channels.
POVershoot is the positive overshoot value over the entire waveform or gated
region. This measurement is applicable only to the analog channels.
Positive Overshoot = ((Maximum - High) / Amplitude) ×100%
PPULSECount is the count of positive pulses.
PWIdth (positive width) is the distance (time) between the middle reference
(default = 50%) amplitude points of a positive pulse. The measurement is made
on the first pulse in the waveform or gated region.
RISe timing measurement finds the rise time of the waveform. The rise time is
the time it takes for the leading edge of the first pulse encountered to rise from a
low reference value (default is 10%) to a high reference value (default is 90%).
This measurement is applicable only to the analog channels.
RMS amplitude measurement finds the true Root Mean Square voltage in the
entire waveform or gated region. This measurement is applicable only to the
analog channels.
SIGMA1 (histogram measurement) measures the percentage of points in the
histogram that are within one standard deviation of the histogram mean.
SIGMA2 (histogram measurement) measures the percentage of points in the
histogram that are within two standard deviations of the histogram mean.
SIGMA3 (histogram measurement) measures the percentage of points in the
histogram that are within three standard deviations of the histogram mean.
STDdev measures the standard deviation (Root Mean Square (RMS) deviation) of
all acquired points within or on the histogram box.
TOVershoot (total overshoot) measures the sum of the positive and negative
overshoot value over the entire waveform or gated region. This measurementis
applicable only to the analog channels.
WAVEFORMS (waveform count) measures the number of waveforms used to
calculate the histogram.
Examples
MEASUREMENT:MEAS2:TYPE FREQUENCY defines measurement 2 as a
measurement of the frequency of a waveform.
MEASUREMENT:MEAS1:TYPE? might return :MEASUREMENT:MEAS1:TYPE RMS
indicating that measurement 1 is defined to measure the RMS value of a waveform.
MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual 2-441

Commands Listed in Alphabetical Order
MEASUrement:
MEAS<x>:UNIts? (Query Only)
Returns the units associated with the specified measurement. The measurement
slots are specified by <x>, which ranges from 1 through 8 (only 4 in
MDO3000 mode
ls).
Group
Measurement
Syntax
MEASUrement:MEAS<x>:UNIts?
Related Commands
MEASUrement:MEAS<x>:TYPe
Returns
This query returns one of the following strings.
Unit string Description
"%"
percent
"/Hz"
inverse hertz
"?"
indeterminate
"A"
amperes
"A/A"
amperes per ampere
"A/V"
amperes per volt
"A/W"
ampere per watt
"A/dB"
amperes per decibel
"A/s"
amperes per second
"AA" amperes squared
"AW"
ampere-watts
"AdB" ampere-decibels
"As" ampere-seconds
"B" bytes
"Hz" hertz
"IRE"
Institute of Radio Engineers units
"S/s"
samples per second
"V" volts
"V/A"
volts per ampere
"V/V"
volts per volt
"V/W"
volts per watt
"V/dB"
volts per decibel
"V/s"
volts per second
"VA" volt-amperes
2-442 MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual

Commands Listed in Alphabetical Order
Unit string Description
"VAR" volt-amperes resistive
"VV" volts squared
"VW" volt-watts
"VdB" volts-decibels
"Vs" volt-seconds
"W"
watts
"W/A"
watts per am
pere
"W/V"
watts per volt
"W/W"
watts per
watt
"W/dB"
watt per decibel
"W/s"
watts per second
"WA"
watt-am
peres
"WV" watt-volts
"WW" watts s
quared
"WdB" watt-decibels
"Wfms" waveforms
"Ws" watt-seconds
"dB" decib
els
"dB/
A"
decibels per ampere
"dB
/V"
decibels per volt
"dB
/W"
decibels per watt
"d
B/dB"
decibels per decibel
"dBA" decibel-amperes
"dBV" decibel-volts
"
dBW"
d
ecibel-watts
"dBdB" decibels squared
"day" days
"degrees" degrees
"div" divi sions
"edges" edges
"hits" hits
"hr" hours
"joules" joules
"min" minutes
"ohms" ohms
"percent"
percent
"pulses" pulses
MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual 2-443