MDO3000 Programmer Manual.pdf - 第234页

Commands Listed in A lphabetical Order Examples BUS:B1:USB:SO URCE:DMINUS CH2 sets the source to channel 2. BUS:B1:USB:SO URCE:DMINUS? might return :BUS:B1:USB:SOU RCE :DMINUS CH4 indicatin g that channel 4 is the source…

100%1 / 1158
Commands Listed in Alphabetical Order
Syntax
BUS:B<x>:USB:
SOUrce:DIFFerential
{CH1|CH2|CH3|CH4|MATH|REF1|REF2|REF3|REF4}
BUS:B<x>:USB
:SOUrce:DIFFerential?
Arguments
CH1–4 specifies an analog waveform as the source. This channel should have
an attached differential probe.
MATH specifies the math waveform as the source.
REF1–4 specifies a reference waveform as the source.
Examples
BUS:B1:USB:SOURCE:DIFFERENTIAL CH2 sets the source to channel 2. You
should have a differential probe attached to channel 2 and connect it to the USB
data signal.
BUS:B1:USB:SOURCE:DIFFERENTIAL? might return
:BUS:B1:USB:SOURCE:DIFFERENTIAL CH4 indicating that channel 4 is
the source.
BUS:B<x>:USB:SOUrce:DMINus
This command specifies the source for the USB bus D- input. If you are using
single-ended probes, you need to set the sources for both the D+ and D- inputs.
Conditions
This command requires a DPO4USB application module for 4000 series models,
and an MDO3USB application module for MDO3000 series models.
Group
Bus
Syntax
BUS:B<x>:USB:SOUrce:DMINus
{CH1|CH2|CH3|CH4|D0|D1|D2|D3|D4|D5|D6|D7|D8
|D9|D10|D11|D12|D13|D14|D15}
BUS:B<x>:USB:SOUrce:DMINus?
Arguments
CH1–CH4 specifies an analog channel as the source waveform for the D- input.
D0-D15 specifies a digital channel as the source waveform for the D- input.
(MSO/MDO4000/B models only as well as MDO3000 and MDO400C models
with option MDO3MSO or MDO4MSO installed.)
MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual 2-203
Commands Listed in Alphabetical Order
Examples
BUS:B1:USB:SO
URCE:DMINUS CH2
sets the source to channel 2.
BUS:B1:USB:SOURCE:DMINUS? might return :BUS:B1:USB:SOU RCE:DMINUS
CH4
indicatin
g that channel 4 is the source.
BUS:B<x>:USB:SOUrce:DPLUs
This command specifies the source for the USB D+ input. If you are using
single-end
ed probes, you need to set the sources for both the D+ and D- inputs.
Conditions
This command requires a DPO4USB application module for 4000 series models,
and an MDO3USB application module for MDO3000 series models.
Group
Bus
Syntax
BUS:B<x>:USB:SOUrce:DPLUs
{CH1|CH2|CH3|CH4|D0|D1|D2|D3|D4|D5|D6|D7|D8
|D9|D10|D11|D12|D13|D14|D15}
BUS:B<x>:USB:SOUrce:DPLUs?
Arguments
CH1–CH4 specifies an analog channel as the source waveform for D+ input.
D0-D15 specifies a digital channel as the source waveform for D+ input.
(MSO/MDO4000/B models only as well as MDO3000 and MDO400C models
with option MDO3MSO or MDO4MSO installed.)
Examples
BUS:B1:USB:SOURCE:DPLUS CH1 sets the D+ source to channel 1.
BUS:B1:USB:SOURCE:DPLUS? might return : BUS:B1:USB:SOURCE:DPLUS
CH3
indicating that channel 3 is the source.
BUS:LOWerthreshold:CH<x>
This command sets the lower threshold for each channel. This applies to all search
and trigger types that use the channel.
Group
Bus
Syntax
BUS:LOWerthreshold:CH<x> {<NR3>|ECL|TTL}
BUS:LOWerthreshold:CH<x>?
2-204 MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual
Commands Listed in Alphabetical Order
Arguments
<NR3> isafloati
ng point number that specifies the threshold, in volts.
ECL specifies a preset ECL high level of -1.3V.
TTL specifies a preset TTL high level of 1.4V.
Examples
BUS:LOWERTHRESHOLD:CH1 TTL sets the CH1 lower threshold to 800mV.
BUS:LOWERTHRESHOLD:CH1? might return :BUS:LOWERTHRESHOLD:CH1
-800.0000E-3
indicatingtheCH1lowerthresholdis-800mV.
BUS:LOWerthreshold{:MATH|:MATH1}
This command specifies the lower threshold for the math waveform. This will
apply to all search and trigger types that use the math waveform.
Group
Bus
Syntax
BUS:LOWerthreshold{:MATH|:MATH1} {<NR3>|ECL|TTL}
BUS:LOWerthreshold{:MATH|:MA
TH1}?
Related Commands
BUS:UPPerthreshold{:MATH|:MATH1}
Arguments
<NR3> is a floating point number that specifies the lower threshold for the
reference waveform, in volts.
ECL ECL (-1.3 volts). Note that this setting is constrained, depending upon the
vertical scale of the specified math waveform.
TTL TTL (1.4 volts). Note that this setting is constrained, depending upon the
vertical scale of the specified math waveform.
Examples
BUS:LOWerthreshold:MATH TTL sets the lower threshold for the math
waveform to 1.4 volts.
BUS:LOWerthreshold:MATH? might return 0.0E+0, which is the default.
BUS:LOWerthreshold:REF<x>
This command sets the lower threshold for each reference waveform. This applies
to all search and trigger types that use that reference waveform.
Group
Bus
MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual 2-205