MDO3000 Programmer Manual.pdf - 第996页
Commands Listed in A lphabetical Order SA V e:W A VEform :FILEFormat , WFMIn pre: NR_Pt Examples WFMOUTPRE:NR_ PT? might return :W FMOU TPRE:NR_PT 10000 indicating that there are 10000 data points to be sent. WFMOutpre:P…

Commands Listed in Alphabetical Order
WFMOutpre:BYT
_Or,
WFMOutpre:BIT_Nr,
WFMOutpre:BN_Fmt
Arguments
ASCii specifies that the outgoing data is to be in ASCII format. Waveforms
will be sent as
<NR1> numbers.
BINary specifies that outgoing data is to be in a binary format whose further
specification is determined by WFMOutpre:BYT_Nr, WFMOutpre:BIT_Nr,
WFMOutpre:BN_Fmt and WFMOutpre:BYT
_Or.
Examples
WFMOUTPRE:ENCDG? might return :WFMOUTPRE:ENCDG BIN indicating that
outgoing waveform data will be sent
in binary format.
WFMOUTPRE:ENCDG ASC specifies that the outgoing waveform data will be sent
in ASCII format.
WFMOutpre:NR_Pt? (Query Only)
This query returns the number of data points in the waveform record that will
be transmitted in response to a
CURVe? query. This value is the adjusted
range specified by
DATA:START and DATA:STOP commands. Note that the
oscilloscope automatically adjusts the
DATA:START and DATA:STOP values
when the
DATA:STOP valueislessthantheDATA:START value,andwhenthe
DATA:START and/or DATA:STOP value is greater than the record length of the
source waveform. The adjusted
DATA:START and DA TA:STOP values determine
WFMOUTPRE:NR_PT.(YoucanuseDATa:STARt and DATa:ST OP to transfer
partial waveforms.) If the waveform specified by the DATa:SOUrce command is
not turned on, an error will be generated.
(See page 2-95, Waveform Transfer Command Group.)
Group
Waveform Transfer
Syntax
WFMOutpre:NR_Pt?
Related Commands
CURVe,
DATa,
DATa:STARt,
DATa:STOP,
SAVe:WAVEform,
MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual 2-965

Commands Listed in Alphabetical Order
SAVe:WAVEform
:FILEFormat,
WFMInpre:NR_Pt
Examples
WFMOUTPRE:NR_PT? might return :W FMOUTPRE:NR_PT 10000 indicating that
there are 10000 data points to be sent.
WFMOutpre:PT_Fmt? (Query Only)
This query returns the point format of the data points in the outgoing waveform
record transferred using the
CURVe? query. The returned values can be Y, which
indicates normal waveform points for YT format, or ENV, which indicates
envelope mode format in which the data is returned as a series of min/max pairs.
The minimum value precedes the maximum.
The outgoing waveform is specified by the DATa:SOUrce command. The query
command will time out and an error will be generated if the waveform specified
by DATa:SOUrce is not turned on.
(See page 2-95, Waveform Transfer Command Group.)
(See page D-1, Waveform Transfer (WFMOutpre and CURVe Query) Examples.)
Group
Waveform Transfer
Syntax
WFMOutpre:PT_Fmt?
Related Commands
CURVe, DATa:SOUrce
Examples
WFMOUTPRE:PT_FMT? might return :WFMOutp re:PT_Fmt EN V in
dicating that
the waveform data is a series of min-max pairs.
WFMOutpre:PT_Off? (Query Only)
This query always returns 0 if the waveform specified by DATA:SOUrce is on or
displayed. If the waveform is not displayed, the query form generates an error. (It
is provided for compatibility with other Tektronix oscilloscopes).
(See page 2-95, Waveform Transfer Command Group.)
(See page D-1, Waveform Transfer (WFMOutpre and CURVe Query) Examples.)
Group
Waveform Transfer
2-966 MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual

Commands Listed in Alphabetical Order
Syntax
WFMOutpre:PT_
Off?
Related Commands
DATa:SOUrce
Arguments
Arguments are ignored.
Examples
WFMOUTPRE:PT_OFF? might return WFMOUTPRE:PT_OFF 0.
WFMOutpre:PT_ORder? (Query Only)
This query returns the point ordering, which is always linear (included for
compatibility with other Tektronix oscilloscopes).
(See page 2-95, Waveform Transfer Command Group.)
(See page D-1, Wa veform Transfer (WFMOutpre and CURVe Query) Exampl
es.)
Group
Waveform Transfer
Syntax
WFMOutpre:PT_ORder?
Related Commands
DATa:SOUrce
Examples
WFMOUTPRE:PT_ORDER? returns :WFMOUTPRE:PT_ORDER LINEAR.
WFMOutpre:REFLEvel? (Query Only)
This query returns the Reference Level of the outgoing waveform. It appliesonly
to the four frequency domain waveforms (RF Normal, RF Average, RF Max Hold,
and RF Min Hold). The units are in watts.
Conditions
MDO3000, MDO4000/B, or MDO4000C models with option SA3 or SA6 only.
Group
Waveform Transfer
Syntax
WFMOutpre:REFLEvel?
MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual 2-967