MDO3000 Programmer Manual.pdf - 第401页
Commands Listed in Alphabetical Order Group Mask Syntax MASK:COUNt RESET Related Commands MASK:COUNt:HITS? MASK:COUNt:SEG<x>:HITS? MASK:COUNt:F AILURES? Examples MASK:COUNt RESET resets to zero the number of h its …

Commands Listed in Alphabetical Order
Examples
MASK:COPy:SOU
rce
E1Coax specifies that the source for a user-defined custom
mask (to be created with the command
MASK:COPy:USER)istobeastandard
ITU-T E1 Coaxial Pair mask.
MASK:COPy:SOUrce? might return NONE, indicating that no source has been
specified.
MASK:COPy:
USER (No Query Form)
This creates a user-defined custom mask by making a copy of the source mask
that was specified prior with the command .MASK:COPy:SOUrce The source
mask coul
d be a standard, limit or another custom mask.
A series of examples showing how to use mask commands for typical tasks
is inclu
ded in an appendix. (See page E-1, Mask/Limit Command Sequence
Examples.)
Conditions
This command requires a DPO4LMT application module for 4000 series models,
and an MDO3LMT application module for MDO3000 series models.
Group
Mask
Syntax
MASK:COPy:USER
Related Commands
MASK:CUSTom
MASK:COPy:SOUrce
Examples
MASK:COPy:USER creates a user-defined custom mask from a copy of the source
mask.
MASK:COUNt (No Query Form)
This command resets to zero the number of hits and failures for all mask segments.
A series of examples showing how to use mask commands for typical tasks
is included in an appendix. (See page E-1, Mask/Limit Command Sequence
Examples.)
Conditions
This command requires a DPO4LMT application module for 4000 series models,
and an MDO3LMT application module for MDO3000 series models.
2-370 MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual

Commands Listed in Alphabetical Order
Group
Mask
Syntax
MASK:COUNt RESET
Related Commands
MASK:COUNt:HITS?
MASK:COUNt:SEG<x>:HITS?
MASK:COUNt:FAILURES?
Examples
MASK:COUNt RESET resets to zero the number of hits and failures for all mask
segments.
MASK:COUNt:FAILURES? (Query Only)
This query returns the number of pass/fail mask tests that have failed.
A series of examples showing how to use mask commands for typical tasks
is included in an appendix. (See page E-1, Mask/Limit Command Sequence
Examples.)
Conditions
This command requires a DPO4LMT application module for 4000 series models,
and an MDO3LMT application module for MDO3000 series models.
Group
Mask
Syntax
MASK:COUNt:FAILURES?
Related Commands
MASK:COUNt:HITS?
MASK:COUNt:SEG<x>:HITS?
Returns
Integer which represents the number of pass/fail mask tests that have failed.
Examples
MASK:COUNT:FAILURES? might return :MASK:COUNT:FA ILURES 3, showing
that three tests have failed.
MASK:COUNt:HITS? (Query Only)
This query returns the sum of all hits in all mask segments.
MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual 2-371

Commands Listed in Alphabetical Order
Aseriesofexam
ples showing how to use mask commands for typical tasks
is included in an appendix. (See page E-1, Mask/Limit Command Sequence
Examples.)
Conditions
This command requires a DPO4LMT application module for 4000 series models,
and an MDO3LMT application module for MDO3000 series models.
Group
Mask
Syntax
MASK:COUNt:HITS?
Related Commands
MASK:COUNt
MASK:COUNt:SEG<x>:HITS?
Returns
<NR1>
Examples
MASK:COUNT:TOTAL? might return :MASK:COUNT:TOTAL 150, showing 150
hits have occurred.
MASK:COUNt:SEG<x>:HITS? (Query Only)
This query returns the number of hits for the specified mask segment. There
are up to 8 segments.
A series of examples showing how to use mask commands for typical tasks
is included in an appendix. (See page E-1, Mask/Limit Command Sequence
Examples.)
Conditions
This command requires a DPO4LMT application module for 4000 series models,
and an MDO3LMT application module for MDO3000 series models.
Group
Mask
Syntax
MASK:COUNt:SEG<x>:HITS?
Related Commands
MASK:COUNt:HITS?
MASK:COUNt
2-372 MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual