MDO3000 Programmer Manual.pdf - 第949页
Commands Listed in Alphabetical Order T able 2-57: Available HDTV formats (cont.) HDTV format Description 720p50 750 lines (720 active), 1280 x 720 pixel, progressive, 50 fps 720p60 750 lines (720 active), 1280 x 720 pix…

Commands Listed in Alphabetical Order
Group
Trigger
Syntax
TRIGger:A:VIDeo:STANdard {NTSc|PAL|SECAM|BILevelcustom|
TRILevelcustom| HD480P60|HD576P50|HD720P30|HD720P50
|HD720P60|HD875I60|HD1080P24|HD1080SF24|HD1080I50
|HD1080I60|HD1080P25|HD1080P30|HD1080P50|HD1080P60}
TRIGger:A:VIDeo:STANdard?
Related Commands
TRIGger:A:VIDeo:CUSTom{:FORMat|:TYPe}, TRIGger:A:VIDeo:CUSTom:
LINEPeriod, TRIGger:A:VIDeo:CUSTom:SYNCInterval
Arguments
NTSc sets the oscilloscope to trigger on video signals that meet the NTSC
525/60/2:1 standard (a line rate of 525 lines per frame and a field rate of 60 Hz).
PAL sets the oscilloscope to trigger on video signals that meet the NTSC
625/50/2:1 standard (a line rate of 625 lines per frame and a field rate of 50 Hz).
SECAM sets the oscilloscope to trigger on video signals that meet the SECAM
standard.
BILevelcustom sets the oscilloscope to trigger on video horizontal scan rate
parameters defined by the TRIGger:A:VIDeo:CUSTom{:FORMat|:TYPe},
TRIGger:A:VIDeo:CUSTom:LINEPeriod and TRIGger:A:VIDeo:CUSTom:
SYNCInterval commands. (Requires installation of a DPO4VID application
module for 4000 series models.)
TRILevelcustom sets the oscilloscope to trigger on video horizontal scan rate
parameters defined by the TRIGger:A:VIDeo:CUSTom{:FORMat|:TYPe},
TRIGger:A:VIDeo:CUSTom:LINEPeriod command. (Requires installation of a
DPO4VID application module for 4000 series models.)
HD480P60|HD576P50|HD720P30|HD720P50|HD720P60|HD875I60
|HD1080P24|HD1080SF24|HD1080I50|HD1080I60|HD1080P25|HD1080P3 0
|HD1080P50|HD1080P60
set the oscilloscope to trigger on an HDTV video
signal that meets standards defined in the following table. (Requires installation
of a DPO4VID application module for 4000 series models.)
Table 2-57: Available HDTV formats
HDTV format Description
480p60
525 lines (480 active), 640 or 704 x 480
pixel, progressive, 60 fps
576p50
EDTV with 625 lines (576 active), 1024 x 576
pixel, progressive, 50 fps
720p30
750 lines (720 active), 1280 x 720 pixel,
progressive, 30 fps
2-918 MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual

Commands Listed in Alphabetical Order
Table 2-57: Available HDTV formats (cont.)
HDTV format Description
720p50
750 lines (720 active), 1280 x 720 pixel,
progressive, 50 fps
720p60
750 lines (720 active), 1280 x 720 pixel,
progressive, 60 fps
875i60
875 active lines, interlaced, 60 fps
1080i50
1125 Lines (1080 active), 1920 x 1080 pixel,
interlaced, 50 fps
1080i60
1125 lines (1080 active), 1920 x 1080 pixel,
interlaced, 60 fps
1080p24
1125 lines (1080 active), 1920 x 1080 pixel,
progressive, 24 fps
1080sF24
1125 lines (1080 active), 1920 x 1080 pixel,
progressive (sF), 2 4 fps
1080p25
1125 lines (1080 active), 1920 x 1080 pixel,
progressive, 25 fps
1080P30
1125 lines (1080 active), 1920 x 1080 pixel,
progressive, 30 fps
1080P50
1125 lines (1080 active), 1920 x 1080 pixel,
progressive, 50 fps
1080P60
1125 lines (1080 active), 1920 x 1080 pixel,
progressive, 60 fps
Examples
TRIGGER:A:VIDEO:STANDARD NTSC sets the oscilloscope to trigger on
NTSC-standard video signals.
TRIGGER:A:VIDEO:STANDARD? might return :TRIGger:A:VIDeo:STANDARD
NTSC
indicating that the oscilloscope is set to trigger on an NTSC format.
TRIGger:A:VIDeo{:SYNC|:FIELD}
This command sets the video field to use for triggering on video signals (odd
fields, even fields, all fields, all lines, numeric).
Conditions
This command requires a DPO4VID application module to use any standard
besides NTSc, PAL, or SECAM, except for MDO3000 models, which do not
require an application module.
Group
Trigger
MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual 2-919

Commands Listed in Alphabetical Order
Syntax
TRIGger:A:VID
eo{:SYNC|:FIELD}
{ODD|EVEN|ALLFields|ALLLines|NUMERic}
TRIGger:A:VIDeo{:SYNC|:FIELD}?
A
rguments
ODD argument sets the oscilloscope to trigger on interlaced video odd fields.
EVEN argument sets the oscilloscope to trigger on interlaced video even fields.
ALLFields argument sets the oscilloscope to trigger on all fields.
ALLLines argument sets the oscilloscope to trigger on all video lines.
NUMERic argument sets the oscilloscope to trigger on the video signal line
specified by the TRIGger:A:VIDeo:LINE command.
Examples
TRIGGER:A:VIDEO:FIELD EVEN sets the A video trigger so that it will trigger
on even fields.
TRIGGER:A:VIDEO:FIELD? might return :TRIGGER:A:VIDEO:FIELD
ALLFIELDS
indicating that the A video will trigger on all video fields.
TRIGger:B
Sets the B trigger level to 50% of minimum and maximum. The query form
of this command returns the B trigger parameters. This command is similar to
selecting B Event (Delayed) Trigger Setup from the Trigger menu and then
viewing the current setups.
Group
Trigger
Syntax
TRIGger:B SETLevel
TRIGger:B?
Related Commands
TRIGger:A
Arguments
SETLevel sets the B trigger level to 50% of MIN and MAX.
Examples
TRIGGER:B SETLEVEL sets the B trigger level to 50% of MIN and MAX.
TRIGGER:B? might return the following B trigger parameters:
:TRIGGER:B:STATE 0;TYPE EDGE; LEVEL -220.0000E-3;BY
TIME;EDGE:SOURCE CH1;SLOPE RISE;CO UPLING DC; :TRIGGER:B:TIM E
16.0000E-9;EVENTS:COUNT 2
2-920 MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual