Commands Listed in Alphabetical Order
Syntax
BUS:B<x>:DISp
lay:FORMat
{BINary|HEXadecimal|ASCII|MIXed|MIXED2|BLOCKHEX}
BUS:B<x>:DIS
play:FORMat?
Related Commands
BUS:B<x>:TYPe
Arguments
BINary All values are displayed in binary.
HEXadecimal All values are displayed in hexadecimal.
ASCII All values are displayed in an ASCII format, for RS-232 only.
MIXed Values are displayed in a mixture of hexadecimal, binary, and decimal,
depending on the field.
MIXED2 Values are displayed in a mixture of hexadecimal, binary, decimal and
ASCII, depending on the field.
BLOCKHEX Displays the 16-bits of each payload as a block of 4 hexadecimal
digits.
BUS:B<x>:DISplay:TYPe
Specifies the display type for bus. You can set up the bus to display the protocol
information, the logic waveforms that comprise the bus, or both.
Group
Bus
Syntax
BUS:B<x>:DISplay:TYPe {BUS|BOTh}
BUS:B<x>:DISplay:TYPe?
Arguments
BUS displays the bus waveforms only.
BOTh displays both the bus and logic waveforms.
BUS:B<x>:ETHERnet:PRObe
This command specifies the Ethernet probe type: differential or single-ended. The
default is DIFFerential.
B<x> is the bus number 1-4. 1-3 for the MDO4000C and
1-2 for the MDO3000.
Conditions
This command requires a DPO4ENET application module for DPO/MSO4000B
and MDO4000/B/C models.
MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual 2-173
Commands Listed in Alphabetical Order
Group
Bus
Syntax
BUS:B<x>:ETHERnet:PRObe {DIFFerential|SINGleended}
BUS:B<x>:ETHERnet:PRObe?
Related Commands
BUS:B<x>:ETHERnet:SOUrce:DIFFerential
BUS:B<x>:ETHERnet:SOUrce:DMINus
BUS:B<x>:ETHERnet:SOUrce:DPLUs
Arguments
DIFFerential
SINGleended
Examples
BUS:B1:ETHERnet:PRObe DIFFerential specifies that
a differential probe is connected to the input channels
specified by
BUS:B<x>:ETHERnet:SOUrce:DPLUs and
BUS:B<x>:ETHERnet:SOUrce:DMINus.
BUS:B1:ETHERnet:PRObe?
might return SINGL EENDED, indicating that the
probe type has been set to single-ended.
BUS:B<x>:ETHERnet:PROTOcol
Use this command to set the Ethernet protocol type to TCP/IPv4, or to OTHER.
The default is IPV4.
NOTE. The commands TRIGger:A:BUS:B<x>:ETHERnet:CONDition DATa and
SEARCH:SEARCH<x
>:TRIGger:A:BUS:B<x>:ETHERnet:CONDition DATa
are impacted by the setting of this command.
Conditions
This command req
uires a DPO4ENET application module for DPO/MSO4000B
and MDO4000/B/C models.
Group
Bus
Syntax
BUS:B<x>:ETHERnet:PROTOcol {IPv4|OTHER}
BUS:B<x>:ETHERnet:PROTOcol?
Related Commands
TRIGger:A:BUS:B<x>:ETHERnet:CONDition
2-174 MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual
Commands Listed in Alphabetical Order
SEARCH:SEARCH
<x>:TRIGger:A:BUS:B<x>:ETHERnet:CONDition
Arguments
IPv4 sets the E
thernet protocol type to Internet Protocol version 4.
OTHER sets the Ethernet protocol type to other than IPv4.
Examples
BUS:B1:ETHERnet:PROTOcol IPv4 specifies IPv4 as the Ethernet protocol.
BUS:B1:ETHERnet:PROTOcol? might return OTHER.
BUS:B<x>:ETHERnet:SOUrce:DIFFerential
This command specifies the Ethernet data source for differential input. The
supported source waveforms are channels 1–4, math waveform, and reference
waveforms 1–4. The default is channel 1.
Conditions
This command requires a DPO4ENET application module for DPO/MSO4000B
and MDO4000/B/C models.
Group
Bus
Syntax
BUS:B<x>:ETHERnet:SOUrce:DIFFerential {CH1|CH2|CH3|CH4|MATH
|REF1|REF2|REF3|REF4}
BUS:B<x>:ETHERnet:SOUrce:DIFFerential?
Related Commands
BUS:B<x>:ETHERnet:PRObe
TRIGger:A:BUS:B<x>:ETHERnet:CONDition
SEARCH:SEARCH<x>:TRIGger:A:BUS:B<x>:ETHERnet:CONDition
Arguments
CH1–4 specifies to use one of the channels 1–4 as the Ethernet data source for
differential input
.
MATH specifies to use the math waveform as the source for Ethernet data
differential inpu
t
REF1–4 specifies to use one of the reference waveforms 1–4 as the source for
Ethernet data dif
ferential input.
Examples
BUS:B1:ETHERnet:SOUrce:DIFFerential ref4 specifies to use reference
waveform 4 as the source for the Ethernet data differential input.
MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual 2-175