Command Groups
Table 2-42: Ver
tical Commands
Command Description
AUXin?
Returns Aux In
put connector parameters
AUXin:PRObe Returns all information concerning the probe attached to Aux Input connector
AUXin:PRObe:AUTOZero Sets the TekVPI probe attached to the Aux Input connector to autozero
AUXin:PRObe:CALibrate:CALIBRATABLe?
This query i
ndicates whether the attached probe is calibratable.
AUXin:PRObe:COMMAND Sets the state of the specied probe control
AUXin:PRObe:DEGAUss Starts a degauss/autozero cycle on a TekVPI current probe attached to the
Aux Input connector
AUXin:PRObe:DEGAUss:STATE? Returns the degauss state of the TekVPI current probe attached to the Aux
Input co
nnector
AUXin:P
RObe:FORCEDRange
This com
mand species the range of the TekVPI probe attached to the Aux
Input connector
AUXin:PRObe:GAIN This command species the gain factor of the probe that is attached to the
Aux Input connector
AUXin:PRObe:ID:SERnumber? Returns the serial number of the probe that is attached to the Aux Input
conne
ctor
AUXi
n:PRObe:ID:TYPe?
Retu
rns the type of probe that is attached to the Aux Input connector
AUXi
n:PRObe:RESistance?
Retu
rns the resistance of the probe that is attached to the Aux Input connector
AUX
in:PRObe:SIGnal
Thi
s command species the input bypass setting on VPI probes that support
input bypass
AUXin:PRObe:UNIts? Returns the units of measure of the probe that is attached to the Aux Input
connector
CH<x>? Returns vertical parameters for the specied channel
CH<x>:AMPSVIAVOLTs:ENA ble This command species the state of the amps via volts feature for the specied
c
hannel
C
H<x>:AMPSVIAVOLTs:FACtor
T
his command species the amps via volts factor for the specied channel
CH<x>:BANdwidth This command species the bandwidth of the specied channel
CH<x>:COUPling This command species the coupling setting for the specied channel
CH<x>:DESKew This command species the deskew time for the specied channel
CH<x>:INVert This command species the invert function for the specied channel
CH<x>:LABel This command species the waveform label for channel <x>
CH<x>:OFFSet This command speci es the channel offset
CH<x>:POSition This command species the channel vertical position
CH<x>:PRObe? Returns the gain, resistance, units, and ID of the probe that is attached to
the specied channel
CH<x>:PRObe:AUTOZero Sets the TekV PI probe attached to the specied channel input to autozero
CH<x>:PRObe:CALibrate This command executes a calibration or initialization for the probe attached
to the auxilliary input, if the probe is calibratable.
CH<x>:PRObe:CALibrate:CALIBRATAB Le? This query returns the state of the probe attached to channel 1–4, either 0 if
the probe is not calibratable, or 1 if the probe is calibratable.
2-92 MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual
Command Groups
Table 2-42: Vertical Commands (cont.)
Command Description
CH<x>:PRObe:CALibrate:STATE? This query returns the calibration state of the probe connected to the specied
channel.
CH<x>:PRObe:COMMAND Sets the state of the speci ed probe control
CH<x>:PRObe:DEGAUss Starts a degauss/autozero cycle on a TekVPI current probe attached to the
specied channel input
CH<x>:PRObe:DEGAUss:STATE? Returns the state of the probe degauss
CH<x>:PRObe:FORCEDRange This command species the range on a TekVPI probe attached to the specied
channel
CH<x>:PRObe:GAIN This command species the gain factor of the probe that is attached to the
specied channel
CH<x>:PRObe:ID? Returns the type and serial number of the probe that is attached to the
specied channel
CH<x>:PRObe:ID:SERnumber? Returns the serial number of the probe that is attached to the specied channel
CH<x>:PRObe:ID:TYPe? Returns the type of probe that is attached to the specied channel
CH<x>:PRObe:MODel This command species the probe model for the specied channel
CH<x>:PRObe:PROPDELay This command species the propagation delay for the probe connected to
the specied channel
CH<x>:PRObe:RECDESkew? Returns the recommended deskew for the probe connected to the specied
channel
CH<x>:PRObe:RESistance? Returns the resistance of the probe that is attached to the specied channel
CH<x>:PRObe:SIGnal This command species the input bypass setting of channel <x>TekVPI probe
CH<x>:PRObe:UN Its? Returns the units of measure of the probe that is attached to the specied
channel
CH<x>:SCAle This command species the vertical scale of the specied channel
CH<x>:TERmination This command species channel input termination
CH<x>:YUNits This command species the units for the specied channel
D<x>
Returns parameters for digital channel <x>
D<x>:LABel
This command species the waveform label for digital channel<x>
D<x>:THReshold
This command species the logical threshold for the digital channel <x>, where
x is the digital channel number D0 D15.
D<x>:POSition This command species the vertical position for digital channel <x>
DESkew Causes the deskew values for all channels to be set to the recommended
values
DESkew:DISPlay Species the state of the deskew table display.
DISplay:INTENSITy:BACKLight:AUTODim:TIMe This command species the state of the deskew table display
REF<x>? Returns reference waveform data for channel <x>
REF<x>:DATE? Returns the date that a reference waveform was stored
REF<x>:HORizontal:DELay:TIMe This command species the horizontal position of the specied reference
waveform in percent of the waveform that is displayed to the right of the center
vertical graticule
MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual 2-93
Command Groups
Table 2-42: Vertical Commands (cont.)
Command Description
REF<x>:HORizontal:SCAle This command species the horizontal scale for a reference w aveform
REF<x>:LABel
This command species the specied reference waveform label
REF<x>:TIMe? Returns the time that a reference waveform was stored
REF<x>:VERTical:POSition This command species the vertical position of the specied reference
waveform
REF<x>:VERTical:SCAle This command species the reference waveform vertical scale in vertical
units/div
SELect? Returns information on which waveforms are on or off and which waveform
is selected.
SELect:{BUS<x>|B<x>} Turnsonoroffthespecied bus waveform or returns whether the specied
bus channel is on or off
SELect:CH<x> Turnsonoroffthespecied waveform or returns whether the specied
channel is on or off
SELect:CONTROl This command species the waveform that is selected as the implied recipient
of channel-related commands
SELect:DAll This command turns on or off all digital channels (D0 D15).
SELect:D<x> Turns on the display of digital channel <x> and resets the acquisition
SELect{:MATH|:MATH1} Turns on or off the math waveform or returns whether the math waveform is
on or off
SELect:REF<x> Turnsonoroffthespecied reference waveform or returns whether the
specied reference waveform is on or off
VideoPictureCommandGroup
The video picture features as well as triggering on a video signal are included
standard with the MDO3000 series models. These features require the DPO4VID
application module for use with MSO/DPO4000B and the MDO4000/B/C models.
Use the video picture commands for video picture functionality.
Table 2-43: Video Picture Commands
Command Description
VIDPic:AUTOContrast Sets (or queries) the video picture automatic contrast state.
VIDPic:AUTOContrast:UPDATERate Sets (or queries) the number of frames between automatic contrast updates
VIDPic:BRIGHTNess Sets (or queries) the video picture brightness level as an integer percentage.
VIDPic:CONTRast Sets (or queries) the video picture contrast level as an integer percentage.
VIDPic:DISplay Sets (or queries) the video picture display state.
VIDPic:FRAMETYPe
Sets (or queries) the video picture frame type (O DD, EVEN or INTERLAced).
VIDPic:LOCation:HEIght Sets (or queries) the video picture height, in rows.
2-94 MDO4000/B/C, MSO/DPO4000B and MDO3000 Series Oscilloscopes Programmer Manual