Settings 6.3.2 Boards at C&P12 C&P12 Service Manual SIPLACE D4/D4i 207 6.3.2.1 6 . 3 . 2 . 1 8 - f o ld D I P S w it c h o f t h e g a n t r y h e a d d is t r ib u t o r ( in c l. s w it c h S 1 ) – C & P 6 …

Settings
C&P12 6.3.1 Calibrating the C&P Head and Cameras
206 Service Manual SIPLACE D4/D4i
After this adjustment of the incremental encoder you have to check the zero pulse and track signals.
Correct installation should ensure correct count and zero pulse signals. For troubleshooting purposes
(error analysis and fixing), you will need to measures these signals with the oscilloscope. (See service
manual.)
6.3
6.3 C&P12
C&P12
6.3.1
6.3.1 Calibrating the C&P Head and Cameras
Calibrating the C&P Head and Cameras
Automatic calibration of all heads and cameras
6.3.2
6.3.2 Boards at C&P12
Boards at C&P12
All the settings described in this chapter are head-specific and apply here for the C&P12.
The menu may vary, according to the machine type and
configuration.
► In the SITEST menu, select Calibrate Entire Machine
--> All Heads and Cameras to open the adjacent
menu.
► In Job Selection (1) , select the components to be cal-
ibrated.
NOTICE! These two entries (2) are optional.
► To continue calibration with manual handling, select
the four consecutive menus in Section Positions (1)
and the two menu items in the Section Mapping (2).

Settings
6.3.2 Boards at C&P12 C&P12
Service Manual SIPLACE D4/D4i 207
6.3.2.1
6.3.2.1 8-fold DIP Switch of the gantry head distributor (incl. switch S1) – C&P6/12
8-fold DIP Switch of the gantry head distributor (incl. switch S1) – C&P6/12
Switch P0 and P1:
Gantry selection via switch P0 and P1
Switch S1:
▪ ON – Test mode (without delay)
▪ OFF – Default state (with delay of 3.6 ms+/- 300 us) means: Z axis moves downwards, the top LB is
released and the LB down is enabled after a delay of 3.6 ms.
See also
6.2.3.1.1 Description of LEDs on the Gantry Head Distributor [ ➙ 203]
6.2.3.1 Gantry Head Distributor [ ➙ 201]
6.3.2.2 LEDs on gantry head distributor [ ➙ 208]
DIP switch Switch position Designation
1 OFF P0 (see below)
2 OFF P1 (see below)
3 OFF "S1" for test mode (see below)
4 OFF BL – Enable boot loader for serial port
5 OFF Res (Reset) – CAN processor 16 bit (TQ module)
6 OFF C0 – no current function
7 OFF C1 – no current function
8 OFF S2 – switch for DLM head (no current function)
S Gantry 1 Gantry 2 Gantry 3 Gantry 4 Designation
1 OFF ON OFF ON P0
2 OFF OFF ON ON G1

Settings
C&P12 6.3.2 Boards at C&P12
208 Service Manual SIPLACE D4/D4i
6.3.2.2
6.3.2.2 LEDs on gantry head distributor
LEDs on gantry head distributor
Legend
Display functions and signals:
1. CAN signal
2. Power supply
3. Head Processor
4. LEDs C&P12
6.3.2.3
6.3.2.3 SP_12 Digital Intermediate Distributor [00330648-05]
SP_12 Digital Intermediate Distributor [00330648-05]
Intermediate distributor
Legend
1. Intermediate distributor
2. Spacer bolt M3x10
3. Spacer bolt M3x10
4. Spacer bolt M3x10
5. Spacer bolt M3x10
6. Front section of C&P head
7. Connectors X1 and X2 (on the rear side)
The intermediate distributor (1) is fixed to the front part (6)
with four spacer bolts (items 2, 3, 4 and 5). The pressure
sensor is located above the spacer bolts (5), on the back
of the intermediate distribution board. The cover of the in-
termediate distributor is fixed with push buttons.