6.5.12 Conveyor Control TSP 301 Conveyor
Service Manual SIPLACE D4/D4i 241
6.5.12
6.5.12 Conveyor Control TSP 301
Conveyor Control TSP 301
6.5.12.1
6.5.12.1 Jumper Settings for TSP 301
Jumper Settings for TSP 301
DIL switch S4 at TSP 301
* Switches 1 and 2 set the hardware ID 5 for D4/D4i machines and hardware ID 6 for X4I, X series, HF
and D3.ID 7 for Width Adjustment Unit
Legend
1. J7 CAN bus 1 terminating resistor
2. F6 Main Fuse TSP 301
3. F1 - F5 Fuses for the conveyor motors
4. J3 interference loop
5. J6 CAN bus 2 terminating resistor (not used)
6. J2, J1 successor/predecessor station
7. S4 DIL switch
Jumper J1, J2 "downstream/upstream station" at TSP
301
Legend
J1 predecessor station
J2 successor station
J3 interference loop (EMERGENCY STOP on pro-
ductivity lift also switches the placement machine off)
J6 CAN bus 2 terminating resistor (not used)
J7 CAN bus 1 terminating resistor
S X4I D4 X/D3/HF Comments
1* ON ON ON ON
2* OFF ON OFF ON = SIPLACE D4/D4i, OFF: SIPLACE X, HF, D3,
X4I
3 OFF OFF OFF OFF= clamping sensor is no longer used
4ONONOFF OFFONON = quad lane, OFF: default conveyor
5 OFF OFF OFF Not in use
6 OFF ON OFF OFF ON OFF: Default conveyor, ON: quad lane (conveyor
edges fixed on outside)
7 OFF OFF OFF OFF: With width adj unit
ON: Without width adj. unit
8 OFF OFF OFF Not in use
Settings
Conveyor 6.5.12 Conveyor Control TSP 301
242 Service Manual SIPLACE D4/D4i
6.5.12.2
6.5.12.2 Conveyor Control TSP 301 with Siemens Interface
Conveyor Control TSP 301 with Siemens Interface
TSP 301 SMEMA --> Siemens
Legend
1. 10-pin plug for SMEMA interface
X3: upstream station
X4: successor station
2. Connection for Siemens interface
X1: upstream station
X2: successor station
NOTICE! Standard / Option
The SMEMA interface is a standard on all X machines
and the Siemens interface is optional.
The Siemens interface is a standard on all D/Di machines
and the SMEMA interface is optional. The SMEMA inter-
face requires an adapter when used with the D1/2/4/D1i/
D2i/D4i.
WARNING! Risk of irreparable damage to the
TSP board!
The 10 pin Locking clip plug of SMEMA connections must
be disconnected from the TSP 301!
Application: no modification.
Following modification are necessary for using the Sie-
mens interface:
JumperJ1 / J2: need to be moved (see following dia-
gram).
Disconnect the connector X3 and X4 on the TSP 301!
Connect the Siemens interface cable on the connec-
tor X1 and X2.
Jumper J1 and J2 (Siemens/SMEMA)
Settings
6.5.12 Conveyor Control TSP 301 Conveyor
Service Manual SIPLACE D4/D4i 243
6.5.12.3
6.5.12.3 LED Display on Conveyor Control TSP 301
LED Display on Conveyor Control TSP 301
6.5.12.4
6.5.12.4 Assignment Table: LEDs on the TSP 301 Conveyor Control
Assignment Table: LEDs on the TSP 301 Conveyor Control
Conveyor Control TSP 301
1. Connector Siemens PCB handling interface up-
stream station lane 1 with corresponding LEDs PCB
handling
2. Connector Siemens PCB handling interface up-
stream station lane 1 with corresponding LEDs PCB
handling
The connector "Siemens PCB handling interface for the
upstream station of lane 2 with corresponding LEDs for
PCB handling" and the connector "PCB handling inter-
face for the downstream station of lane 2 with corre-
sponding LEDs for PCB handling" are located on the
extension board (similar layout).
Anzeige /Display I / O LED assignment
H1 / F1-F5 Fuse F1-F5, Power supply 40 V
H2 / F6 Fuse F6 Power supply 24V
H4(ao) Initializing / control error
H5(ao) CAN bus 1, active
H6(ao) Flashing: program running
H7(ao) CAN bus 2, active (optional)
H9 Out Interference loop
H14 IN Siemens interface for upstream station
H15 IN Siemens interface for downstream station
H20 IN Lifting table placement area 1: forked light barrier A
H21 IN Lifting table placement area 1: forked light barrier B
H22 IN Lifting table placement area 2: forked light barrier A
H23 IN Lifting table placement area 2: forked light barrier B
H24 IN Laser light barrier, placement area 1: receiver
H25 IN Laser light barrier, placement area 2: receiver
H26 IN Not used