SIPLACE D4-D4i 工程师手册_EN.pdf - 第214页
Settings C&P12 6.3.8 Setting the Light Barrier Down 214 Service Manual SIPLACE D4/D4i ► Check a gain wheth er the 5/100 mm feeler gauge passe s easily (wit hout resis tance) b etween t he Z axis end posit ion stop an…

Settings
6.3.7 Adjusting the Stop for the Z Axis C&P12
Service Manual SIPLACE D4/D4i 213
► For better access to the Z axis end stopper, unscrew the cable clamp at one side and turn it to the
side. Then carefully push the flat ribbon cable to the side.
► Check whether the 5/100 mm feeler gauge passes easily (without resistance) between the Z axis
end stopper and the tension jack (see diagram above).
► If this is not the case, you will need to adjust the Z axis end stopper setting!
► Loosen the Z axis end stopper screw.
► Clamp a 15/100 mm feeler gauge between the Z end stopper and the clamp. Gently press the Z axis
end stopper downwards with the screwdriver and screw tight.
► It should now be more difficult to extract the 15/100 mm feeler gauge.
Z end stopper star gauge mounted
The star gauge ensures that the star is in the correct po-
sition and that the Z axis is pressed upwards.
Z end stopper check and adjust
Legend
1. Z end stopper
2. Feeler gauge
3. Clamping device

Settings
C&P12 6.3.8 Setting the Light Barrier Down
214 Service Manual SIPLACE D4/D4i
► Check again whether the 5/100 mm feeler gauge passes easily (without resistance) between the Z
axis end position stop and the tension jack. If this is not the case, you will need to readjust the setting!
6.3.8
6.3.8 Setting the Light Barrier Down
Setting the Light Barrier Down
NOTICE
When removing the gauge, make sure that the gauge pin is extracted first and that then the star
gauge is removed. If you do not observe this order, the gauge could catch in the segments and
damage these!
NOTICE
The light barrier is set with a test probe to a distance of 1.0 mm to the sleeve.

Settings
6.3.9 Determining the Zero Point Correction for the Star Axis of the C&P Head C&P12
Service Manual SIPLACE D4/D4i 215
6.3.9
6.3.9 Determining the Zero Point Correction for the Star Axis of the C&P Head
Determining the Zero Point Correction for the Star Axis of the C&P Head
Flow chart zero point correction
CAUTION! When performing this task, follow all
instructions exactly!