Settings Conveyor 6.5.11 Lifting Table Functions 240 Service Manual SIPLACE D4/D4i ⇨ Lifting table up: 500 ms +/-20 ms (without lifting table plate ~ 450 +/-20 ms DT / ~360 +/-2 0 ms ET) ⇨ Lifting table down: 480 ms +/-2…

Settings
6.5.11 Lifting Table Functions Conveyor
Service Manual SIPLACE D4/D4i 239
Lifting table down function
Requirements for detecting that the lifting table is down:
▪ 30-35 pulses from the incremental disc
▪ Proximity switch on the lifting table cylinder
▪ Dynamic response for board release of approx. 480 ms
6.5.11.1
6.5.11.1 Adjusting the Speed of the Lifting Table (from SW 602)
Adjusting the Speed of the Lifting Table (from SW 602)
Time needed to move lifting table up with lifting table plate
► Switch the machine on and start the SITEST program.
► In the PCB conveyor functions menu (see adjacent diagram) you can see the travel time for the lifting
table (from SW 602 upwards).
► Click on Actuate Clamp.
Time needed to move lifting table down with lifting table plate
► The lifting table will be moved up and the travel time will be displayed (see diagram).
► Press the Actuate Clamp button again to move the lifting table downwards and to view the travel time
for the downwards movement.
► If the travel times are not inside the tolerance range or if error messages appear during production,
adjust the travel times (displayed since SITEST 60x) as follows:
► Adjust the valve on the lifting table cylinder, so that you get the following values:

Settings
Conveyor 6.5.11 Lifting Table Functions
240 Service Manual SIPLACE D4/D4i
⇨ Lifting table up: 500 ms +/-20
ms (without lifting table plate ~450 +/-20 ms DT / ~360 +/-20 ms ET)
⇨ Lifting table down: 480 ms +/-20
ms (without lifting table plate ~550 +/-20 ms DT / ~600 +/-20 ms ET)
► If malfunctions occur during the downwards movement or if the board is shaken, reduce the lowering
speed accordingly.
Setting valve anticlockwise: Decrease the lifting table moving time
Setting valve clockwise: Increases the lifting table moving time
6.5.11.2
6.5.11.2 Setting the Lifting Table Unit [00358684-05]
Setting the Lifting Table Unit [00358684-05]
Legend
1. (3) adjust valve downwards
2. (4) adjust valve upwards
Setting the damping unit
The damping unit (1) allows the lifting table to move gen-
tly upwards. When the PCB is clamped, it also prevents
excessive bounce by the PCB.
► Check whether the damping unit is fixed with the lock-
nut (2) in the mounting block and that the plunger (3)
of the damping unit is just touching the actuator (4).
In this default setting, the lifting table should move up
gently.
► If this is not the case, loosen the locknut at the mount-
ing block and turn the damping unit approx. one rota-
tion into the mounting block..
► Move the lifting table upwards, with the help of the
software.
► The lifting table should move gently upwards.
The PCB clamping should not engage audibly and
there should be no PCB clamping error message.
► Check the speed of the lifting table and correct where
necessary.

Settings
6.5.12 Conveyor Control TSP 301 Conveyor
Service Manual SIPLACE D4/D4i 241
6.5.12
6.5.12 Conveyor Control TSP 301
Conveyor Control TSP 301
6.5.12.1
6.5.12.1 Jumper Settings for TSP 301
Jumper Settings for TSP 301
DIL switch S4 at TSP 301
* Switches 1 and 2 set the hardware ID 5 for D4/D4i machines and hardware ID 6 for X4I, X series, HF
and D3.ID 7 for Width Adjustment Unit
Legend
1. J7 CAN bus 1 terminating resistor
2. F6 Main Fuse TSP 301
3. F1 - F5 Fuses for the conveyor motors
4. J3 interference loop
5. J6 CAN bus 2 terminating resistor (not used)
6. J2, J1 successor/predecessor station
7. S4 DIL switch
Jumper J1, J2 "downstream/upstream station" at TSP
301
Legend
▪ J1 predecessor station
▪ J2 successor station
▪ J3 interference loop (EMERGENCY STOP on pro-
ductivity lift also switches the placement machine off)
▪ J6 CAN bus 2 terminating resistor (not used)
▪ J7 CAN bus 1 terminating resistor
S X4I D4 X/D3/HF Comments
1* ON ON ON ON
2* OFF ON OFF ON = SIPLACE D4/D4i, OFF: SIPLACE X, HF, D3,
X4I
3 OFF OFF OFF OFF= clamping sensor is no longer used
4ONONOFF OFFONON = quad lane, OFF: default conveyor
5 OFF OFF OFF Not in use
6 OFF ON OFF OFF ON OFF: Default conveyor, ON: quad lane (conveyor
edges fixed on outside)
7 OFF OFF OFF OFF: With width adj unit
ON: Without width adj. unit
8 OFF OFF OFF Not in use