SIPLACE D4-D4i 工程师手册_EN.pdf - 第215页
Settings 6.3.9 Determining the Zero Po int Correction for the Star Axis o f the C&P Head C&P12 Service Manual SIPLACE D4/D4i 215 6.3.9 6 . 3 . 9 D e t e r m in in g t h e Z e r o P o in t C o r r e c t io n f o r…

Settings
C&P12 6.3.8 Setting the Light Barrier Down
214 Service Manual SIPLACE D4/D4i
► Check again whether the 5/100 mm feeler gauge passes easily (without resistance) between the Z
axis end position stop and the tension jack. If this is not the case, you will need to readjust the setting!
6.3.8
6.3.8 Setting the Light Barrier Down
Setting the Light Barrier Down
NOTICE
When removing the gauge, make sure that the gauge pin is extracted first and that then the star
gauge is removed. If you do not observe this order, the gauge could catch in the segments and
damage these!
NOTICE
The light barrier is set with a test probe to a distance of 1.0 mm to the sleeve.

Settings
6.3.9 Determining the Zero Point Correction for the Star Axis of the C&P Head C&P12
Service Manual SIPLACE D4/D4i 215
6.3.9
6.3.9 Determining the Zero Point Correction for the Star Axis of the C&P Head
Determining the Zero Point Correction for the Star Axis of the C&P Head
Flow chart zero point correction
CAUTION! When performing this task, follow all
instructions exactly!

Settings
C&P12 6.3.10 Setting the Mechanical Position of the Valve Positioning Drives
216 Service Manual SIPLACE D4/D4i
6.3.10
6.3.10 Setting the Mechanical Position of the Valve Positioning Drives
Setting the Mechanical Position of the Valve Positioning Drives
▪ Set the motor position of the valve positioning drives "pickup/placement" and "reject" as shown in the
following diagram.
▪ If the new valve plungers are used (s. diag. below) proceed as follows: Take out one valve plunger
and remove the sleeve (2).
▪ Insert the plunger without bushing and carry out the following steps on this segment:
▪ Insert the distance gauge (0.2 mm) between valve plunger and valve casing.
▪ Rotate the valve positioning drive 90 degrees from its initial position. The eccentric of the valve ad-
justment drive will just touch the inner side (1) of the valve plunger.
▪ Fix the motor of the valve drive in this position.
▪ Remember to replace the tube on the valve plunger.
Setting the mechanical position of the valve drive
Set the motor position of the valve positioning drives
"pickup/placement" and "reject" as shown in the diagram.
New valve plunger [00351498-03]
► If the new valve plungers are used (s. diag. on left)
proceed as follows:
⇨ Take out one valve plunger and remove the sleeve
(2).
⇨ Insert the plunger without bushing and carry out
the following steps on this segment:
► Insert the distance gauge (0.2 mm) between valve
plunger and valve casing.
► Rotate the valve positioning drive 90 degrees from its
initial position. The eccentric of the valve adjustment
drive will just touch the inner side (1) of the valve
plunger.
► Fix the motor of the valve drive in this position.
► Remember to replace the tube on the valve plunger.