4 Configuration Installation and Configuration Guide SIPLACE Explorer 4.2 Configuring the Factory Configuration Utility Edition 11/2006 EN 94 → The Load settings from... dialog box will open. Y ou need to establish a con…

100%1 / 130
Installation and Configuration Guide SIPLACE Explorer 4 Configuration
Edition 11/2006 EN 4.2 Configuring the Factory Configuration Utility
93
4.2 Configuring the Factory Configuration Utility
4.2.1 Starting the SIPLACE Factory Configuration Utility
→ Start the SIPLACE Factory Configuration Utility via the Programs → SIPLACE Explorer
2.1 → Factory Configuration Utility menu in Windows.
4
Fig. 4 - 28 RTE Windows Start menu
→ Or click on the Factory Configuration Utility icon on your desktop.
NOTE
Access to the Runtime Environment tools is restricted or permitted as required, by using the
SE Security Manager. For details of the relevant settings in the SE Security Manager, refer
to the Getting Started for SIPLACE Explorer 2.1. 4
4 Configuration Installation and Configuration Guide SIPLACE Explorer
4.2 Configuring the Factory Configuration Utility Edition 11/2006 EN
94
→ The Load settings from... dialog box will open. You need to establish a connection to the
factory database, before data can be called up.
4
Fig. 4 - 29 Factory - load settings from
→ Please specify the following information:
–Host name
– Port number
– Database name
–User name
– Database password
→ After entering the database access parameters, we strongly recommend that you check the
connection to the database. Click Test to check whether the connection to the database can
be established.
→ If the connection does not function properly, you will see the following information box:
4
Fig. 4 - 30 DB error
Installation and Configuration Guide SIPLACE Explorer 4 Configuration
Edition 11/2006 EN 4.2 Configuring the Factory Configuration Utility
95
→ Click on the Setup DB Connection button to start the DB Connection Wizard setup
sequence and configure the SIPLACE Explorer factory database. Follow the instructions at
“Database Connection Wizard” on page 111.
→ If the connection functions properly, you will see the following information box:
4
Fig. 4 - 31 Success
→ Click OK. The system will check the database data. If the database has data from SIPLACE
Explorer V2.0 or V1.2, you will need to convert the database for SIPLACE V2.1, due to the
changed data structure in the SIPLACE Explorer V2.1 database. In this case, the Convert
Database dialog box will open.
NOTE
Observe the following for database conversion:
- You will need database administrator rights.
- If you have started the conversion, this process can not be stopped.
- The conversion time depends on the size of the database. It may take up to an hour. 4
4
Fig. 4 - 32 Convert database