4OM-1733
1-4-4
4.1.3 Drain Check
Cycle : Every Week (Required Time : 5 minutes)
Cap
Drain
Fig. 4A4-4
Procedure
Prepare a container and pull down the black cap each on the lter case lower
section to drain.
1208-001
4.1 Air Source
4OM-1733
1-4-5
4.1.4 Filter Cleaning
Cycle : Every 3 Months (Required Time : 5 minutes)
Filter
Fig. 4A4-5
Procedure
(1) Turn the cover unit in the direction shown in the gure, using the air-lter
case removing jig to remove the cover.
Fig. 4A4-6
1208-001
4.1 Air Source
4OM-1733
1-4-6
(2) While rotating the lter holder counterclockwise, pull it out.
Filter Holder
Fig. 4A4-7
(3) Pull out the lter and blow air to it for cleaning.
(4) Insert the lter back in place and turn the lter holder clockwise to attach.
(5) Attach the lter cover.
Note
When the lter has become defective, replace it with a new one.